1.

 

Testing 

Turn  the  LUX  adjuster  fully  clockwise  (SUN);  turn  the  TIME  adjuster  fully  anti-clockwise  to  the 
minimum (10s). 

 

Switch on the AC supply and after a 30sec warm-up 
period the sensor will now be in test mode   

 

Walk  test  the  sensor,  when  the  sensor  receives  a 
valid  trigger  signal  within  its  detection  area  the 
lamp  will  turn  on.    If  the  sensor  does  not  receive 
any  other  valid  trigger  signal  then  the  light  should 
switch off 10sec (±3sec). 

 

While  the  lamp  is  on  and  if  the  sensor  receives  additional  valid  trigger  signal  then  the  timer  will 
re-start and the light will remain on. 

 

Adjusting SENS adjuster for desired the detection range.     

 

Walk test immediately outside the area to ensure detection is not possible through walls and floors 
to minimize unwanted activations. 

 

After  testing  the  sensor ensuring  the  required  area  can  be  detected, Turn  the  LUX  adjuster to the 
required light operational level, and adjust the TIME adjuster clockwise to the required time for the 
light duration to be on. 

 
Troubleshooting 

 

The load does switch on: 

o

 

  Please check the connections, and the AC mains supply is on 

o

 

  Please check if the load is operational 

o

 

  Please check the adjustment settings and make the necessary adjustments if required 

 

The sensitivity is poor: 

o

 

Please check if there is any metallic obstructions in front of the sensor   

o

 

Check that the sensor is mounted with in the recommended mounting height 

o

 

Please check if the moving orientation is correct 

 

 

The sensor cannot turn off the load automatically: 

o

 

Please check if there is a lot of metal in the area i.e. metal containers, walls etc. 

o

 

Please check the TIME and SENS adjustments 

o

 

Please  check  if  the  connections  and  that  a  permanent  Live  is  not  connected  directly  to  the 

load 

Содержание PMSMC

Страница 1: ...EMatic_PMSMC_Instructions_Rev01 PMSMC Surface Microwave Sensor Instruction Manual Please read the instruction manual before installing and retain for the user maintenance engineer for future reference ...

Страница 2: ...is very important NOTE The high frequency output of the sensor is 0 2Mw that is just one 5000th of the transmission power of a mobile phone or the output of a microwave oven IMPORTANT NOTE Installation must be performed by a skilled electrician who is familiar with the appropriate standards and technical requirements of the appliance and its proper installation The person carrying out the installa...

Страница 3: ...anted activations After testing the sensor ensuring the required area can be detected Turn the LUX adjuster to the required light operational level and adjust the TIME adjuster clockwise to the required time for the light duration to be on Troubleshooting The load does switch on o Please check the connections and the AC mains supply is on o Please check if the load is operational o Please check th...

Страница 4: ... LED Max 300w or maximum 6 number of LED drivers Environment Please DO NOT dispose of electrical items or packaging as unsorted waste use the recycling facilities provided by your local authorities Due to our policy of continuous improvement we reserve the right to change specification without prior notice Errors and omissions excepted These instructions have been carefully checked prior to public...

Отзывы: