EMatic_PMSMC_Instructions_Rev01
1.
Testing
Turn the LUX adjuster fully clockwise (SUN); turn the TIME adjuster fully anti-clockwise to the
minimum (10s).
•
Switch on the AC supply and after a 30sec warm-up
period the sensor will now be in test mode
•
Walk test the sensor, when the sensor receives a
valid trigger signal within its detection area the
lamp will turn on. If the sensor does not receive
any other valid trigger signal then the light should
switch off 10sec (±3sec).
•
While the lamp is on and if the sensor receives additional valid trigger signal then the timer will
re-start and the light will remain on.
•
Adjusting SENS adjuster for desired the detection range.
•
Walk test immediately outside the area to ensure detection is not possible through walls and floors
to minimize unwanted activations.
•
After testing the sensor ensuring the required area can be detected, Turn the LUX adjuster to the
required light operational level, and adjust the TIME adjuster clockwise to the required time for the
light duration to be on.
Troubleshooting
The load does switch on:
o
Please check the connections, and the AC mains supply is on
o
Please check if the load is operational
o
Please check the adjustment settings and make the necessary adjustments if required
The sensitivity is poor:
o
Please check if there is any metallic obstructions in front of the sensor
o
Check that the sensor is mounted with in the recommended mounting height
o
Please check if the moving orientation is correct
•
The sensor cannot turn off the load automatically:
o
Please check if there is a lot of metal in the area i.e. metal containers, walls etc.
o
Please check the TIME and SENS adjustments
o
Please check if the connections and that a permanent Live is not connected directly to the
load