Model PMCS6
Lighting Maximum Load For
Incandescent (Cos
Θ
=1)
2000W/8A(@240VAC)
Lighting Maximum Load For
Halogen (Cos
Θ
=1)
2000W/8A(@240VAC)
Lighting Maximum Load For
Fluorescent T8 (Cos
Θ
=
0.5)
1500W/12A(@240VAC)
Lighting Maximum Load For
Fluorescent T5 (Cos
Θ
≧
0.9)
1500W/6.9A(@240VAC)
Lighting Load (number of fittings) for
Fluorescent T5
Conditions : Maximum quantity of ballasts and lamps listed
below;
Ballast Q'ty x (Lamp Q'ty x Watt)
22x(4x14W);
20x(2x21W);
20x(2x24W);
15x(2x28W);
15x(2x35W);
12x(2x39W);
12x(2x49W);
10x(2x54W);
10x(1x80W);
Lighting Load (Number of fittings) for
CFL & PL (Setup Conditions)
Conditions : Maximum quantity of lamps/wattage listed
below;
Lamp Q'ty x Watt
10x9W
10x11W or 10x13W or 10x19W ;
10x20W or 10x23W ;
10x24W or 10x26W or 10x27W ;
10x32W or 10x36W or 10x38W ;
10x42W or 10x50W or 10x55W ;
10x80W:
Lighting Load For
10 Qty parallel connection
LED
200W total (Max.)
A501111792R01
Rev03