Ping timeout
: If ping packet is sent, the response packet is not received before timeout, then
this ping is failed.
Max retries
: If the ping is failed, the failed counter will add one. If the failed counter is bigger or
equal to the Max retries, then system will say this interface is unavailable.
If the ping is succeeding, failed counter will be reset to 0 at anytime.
Interval between ping
: The time between twice ping. The unit is second.
3.5.3.1 Failover Advanced settings
Cell Standby
: choose Cell status(connect, disconnect, or radio off) when cell acts as backup
interface.
SMS Alarm
: if need to send SMS alarm when working interface switchover.
3.5.4 DTU
Notes:
1) This feature is for H700 with DTU option only.
2) This feature is conflict with “
Connect Radio module
” and “
GPS send to serial
”. Please
disable the “
DTU
” feature if use “
Connect Radio Module
” or “
GPS send to serial
” feature.