User Manual EE872 Modular Probe for CO

2

, RH, T and p

1  General

This user manual serves for ensuring proper handling and optimal functioning of the device. The user 

manual shall be read before commissioning the equipment and it shall be provided to all staff involved 

in transport, installation, operation, maintenance and repair.

The user manual may not be used for the purposes of competition without the written consent of E+E 

Elektronik® and may not be forwarded to third parties. Copies may be made for internal purposes. All 

information, technical data and diagrams included in these instructions are based on the information 

available at the time of writing.

Intended use

The EE872 modular probe is intended for the measurement of CO

2

, relative humidity (RH), temperature 

(T) and ambient pressure (p). Additionally, the device calculates the dew point temperature (Td). The 

probe is designed for the use in harsh and demanding environments such as agriculture, life stock 

barns, hatchers, incubators, green houses or outdoors. The use of the EE872 other than described in 

this manual is not recommended.

The manufacturer cannot be held responsible for damages as a result of incorrect handling, installation 

and maintenance of the device. Unauthorized modifications of the product lead to loss of all warranty 

claims. The device may only be powered with safety extra-low voltage (SELV).

Disclaimer

The manufacturer or his authorized agent can be only be held liable in case of willful or gross 

negligence. In any case, the scope of liability is limited to the corresponding amount of the order issued 

to the manufacturer. The manufacturer assumes no liability for damages incurred due to failure to 

comply with the applicable regulations, operating instructions or the specified operating conditions. 

Consequential damages are excluded from the liability.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.1.1  General Safety Instructions

•  The device and mainly the filter cap shall not be exposed to unnecessary mechanical stress.

•  Installation, electrical connection, maintenance and commissioning shall be performed by  

qualified personnel only.

•  Use the EE872 only as intended and observe all technical specs. The device must be operated with 

the filter cap on at all times.

•  This device is not appropriate for safety, emergency stop or other critical applications where device 

malfunction or failure could cause injury to human beings.

1.2  Environmental Aspects

Products from E+E Elektronik® are developed and manufactured observing of all relevant requirements 

with respect to environment protection. Please observe local regulations for the device disposal.

For disposal, the individual components of the device shall be separated according to local recycling 

regulations. The electronics shall be disposed of correctly as electronics waste.

Содержание EE872 Series

Страница 1: ...BA_EE872_e V1 2 technical data are subject to change User Manual EE872 Modular Probe for CO2 RH T and p...

Страница 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Страница 3: ...put and RS485 Interface 7 4 Installation 8 5 Setup and Adjustment 8 5 1 EE PCS Product Configuration Software 9 5 2 Digital Interface RS485 with Modbus RTU Protocol 9 5 2 1 Digital Settings 9 5 2 2 Mo...

Страница 4: ...nce In any case the scope of liability is limited to the corresponding amount of the order issued to the manufacturer The manufacturer assumes no liability for damages incurred due to failure to compl...

Страница 5: ...vices are not accidentally used by marking them clearly as faulty A faulty device may only be investigated and possibly repaired by qualified trained and authorized staff If the fault cannot be fixed...

Страница 6: ...ng is activated the RH and T data is not available The calculated Td value is still available All values are available on the digital interface All versions provide CO2 measurement T and p compensated...

Страница 7: ...n pin not connected EE872 set to RS485 interface option P1 in the order code features RS485 interface EE872 set to analogue outputs option GA7 or GA11 in the order code the RS485 interface is active f...

Страница 8: ...with mounting clip HA010227 EE872 with mounting flange HA010226 For outdoor applications the EE872 must be used with the radiation shield HA010510 not included in the scope of supply see data sheet A...

Страница 9: ...Device address baud rate parity and stop bits can be set via 1 EE PCS Product Configuration Software and the Modbus configuration adapter HA011018 The EE PCS can be downloaded free of charge from www...

Страница 10: ...FA1 Temperature T F 50 4003 0xFA2 Temperature T K 50 4005 0xFA4 Dew point temperature Td C 100 4053 0xFD4 Dew point temperature Td F 100 4054 0xFD5 Dew point temperature Td K 100 4074 0xFE9 Tab 3 Inte...

Страница 11: ...abled by factory default can be enabled with the EE PCS Product Configuration Software see above Output signal NAMUR signal level 0 5 V 5 5 V 0 10 V 11 V 4 20 mA 21 mA 0 20 mA 21 mA 6 Maintenance 6 1...

Страница 12: ...rotection cap rubber caps Fig 6 Calibration adapter HA010785 with mounted rubber caps for use as protection cap Procedure Remove the filter cap and install the calibration adapter onto the probe Conne...

Страница 13: ...range 40 60 C 40 140 F Accuracy3 5 60 C 41 140 F typ 0 5 C 0 9 F Outputs Analogue CO2 only 0 5 V 0 10 V 1 mA Load current 1 mA 0 20 mA 4 20 mA 3 wire Load resistance 500 Ohm Digital interface CO2 RH T...

Страница 14: ...0 6460 Office Stuttgart Tel 49 151 538 37 500 E E Elektronik Italy info epluse it Tel 39 02 2707 86 36 E E Elektronik France info epluse fr Tel 33 4 74 72 35 82 E E Elektronik USA office epluse com Of...

Отзывы: