TECHNICAL DATA

For communication with EE871 via E2 interface please see the support literature at www.epluse.com/ee240.

E2 INTERFACE

Measurands

 

CO

2

 

Measurement principle 

Dual wavelength (non-dispersive infrared technology) NDIR

 

Measuring range 

0...2 000 ppm: 

< ± (50 ppm + 2 % from the measured value)

 

Accuracy at 25 °C 

0...5 000 ppm: 

< ± (50 ppm + 3 % from the measured value)

 

and 1 013 mbar

1)

 

(77 °F...14,69 psi)

 

0...10 000 ppm:  

< ± (100 ppm + 5 % from the measured value)   

 

Response time t

63

 

105 s with measured data averaging (smooth output)

 

 

 

60 s without measured data averaging

 

Temperature dependency 

0...2 000 ppm: 

 

 

 

(-20...45 °C) 

(-4...113 °F)

 

0...5 000 ppm: 

typ. ± (1 + CO

2

 concentration [ppm] / 1 000) ppm/°C 

    

0...10 000  ppm:

 

Transmission interval 

Adjustable from 1 s to 1 h

 

by the EE242 base station

General

 

Digital interface 

E2 

(details: www.epluse.com)

Power supply class III 

2)

  

4.75 - 7.5 V DC 

Average current consumption

3)

  120 µA 

(at 1 h transmission interval)...

4.3 mA 

(at 15 sec. transmission interval)

Current peak, max. 

350 mA for 0.05 s

 

Enclosure / protection  rating 

Polycarbonate  (PC) / enclosure  IP65

 

Filter cap 

PTFE

 

Electrical connection  

Connector M12x1

 

Cable length, max. 

10 m 

(32.8 ft)

 

Electromagnetic compatibility 

EN 61326-1 

 

(Industrial enviroment) 

EN 61326-2-3

 

Operating conditions 

-40...60 °C 

(-40...140 °F)

 0...100 %RH (non-condensing) 85...110 kPa 

(12.33...15.95 psi)

 

Storage conditions 

-40...60 °C 

(-40...140 °F)

 0...100 %RH (non-condensing) 70...110 kPa 

(10.15...15.95 psi)

1) For averaging output

2) USA & Canada class 2 supply required, max. supply voltage 30 V DC

3) The average current consumption depends on the measurement interval

For outdoor applications EE871 must be used with the radiation shield order no. HA010507, which protects the device 

against rain, snow, ice, and solar radiation. 

OPERATION OUTDOORS

94

44

174

Ø105 

122

W

20

Ø5