User Manual EE360
Moisture in Oil Sensor | 17
Metal sealing ring
(as a standard contained
with the probe)
1/2" ball valve
Extension
(is not available for
an NPT thread)
Inside diameter
≥
13.1 mm (0.55")
Metal sealing ring
(as a standard contained
with the ball valve set)
Clamping sleeve
Lock nut
Adapter body
Sealing element 2
Sealing element 1
Fig. 8
Installation of the probe by utilizing the ball valve set
Removing the probe
1.
Hold firmly the probe to avoid it being suddenly expulsed when releasing the lock. Do not bend damage the
probe cable.
2.
Loosen slowly the lock nut with a spanner (spanner width 24) only till the probe is pushed out by the
overpressure in the process. Do not completely loosen the lock nut, but only as much as necessary for the
probe to slide.
3.
After the probe has been pushed out of the process up to the stop, close the ball valve.
4.
Remove the probe from the ball valve.
NOTICE
Observe the correct positioning of the sealing element 1 before reinstalling the probe.
Replacement of the sealing element
In case of repeated installations and removals the sealing element 1 can might damaged. It can be replaced by
the user.
Sealing element 1
O-ring seal 13x1.5 mm
FPV3588 Sh A 60±5
Содержание EE360
Страница 1: ...User Manual Moisture in Oil Sensor EE360...