background image

USA

FCC information:

This equipment is tested and in compliance with all requirements for category B concerning part 15 of the FCC regulations. These requirements 

have been set up to ensure an appropriate protection against EMC disturbances in residential areas. This equipment produces, consumes and 

can radiate high frequency energy. If not installed and used in accordance with the information in this manual, the EE240 series can cause EMC 

disturbance. There is no guarantee that EMC disturbance will not affect certain kinds of installations. If the equipment causes EMC disturbance 

during radio and television reception (to be determined by switching the equipment on and off), then it is recommended to take the following 

actions to eliminate the interference:

- Adjust or reposition the antenna

- Increase the distance between the receiving equipment and the wireless transmitter

- Connect the equipment to an outlet on a different circuit as that to which the receiver is connected

- Contact an experienced radio / TV technician

Caution:

Any changes or modifications made to the equipment, which are not carried out by a certified EMC technician may cause failure leading to 

malfunctions.

CANADA

ICES-003 notification:

This equipment complies with the norm ICES-003, category B.

Содержание EE240

Страница 1: ...Manual Hardware and Software Series EE240 Wireless SENSOR FOR HUMIDITY TEMPERATURE CO2 BA_EE240_04_e technical data are subject to change 350118...

Страница 2: ...allations If the equipment causes EMC disturbance during radio and television reception to be determined by switching the equipment on and off then it is recommended to take the following actions to e...

Страница 3: ...M 13 4 1 Point to point EE241 with a single transmitter 13 4 2 Wireless network EE242 with multiple transmitters 13 4 3 Increasing the transmission distance with routers 13 5 CALIBRATION OF MEASUREMEN...

Страница 4: ...ied out unconditionally If disregarded loss injury or damage may be inflicted to people and property In any case E E Elektronik Ges m bH cannot be hold responsible This symbol indicates attention The...

Страница 5: ...SI Australia C Tick C Tick Japan R201WW07215215 R201WW08215142 FCC ID MCQ XBEEPRO2 part 15 of the FCC regulations IC 1846A XBEEPRO2 Canada accept FCC s audit report about the compliance with ICES 003...

Страница 6: ...mission connection A maximum of 10 wireless connections per router base station see outline 2 1 3 2 1 2 Installation of a wireless system 2 1 3 Example for a wireless measurment setup Sensing probe TR...

Страница 7: ...re and a humidity measurement The EE241 can communicate with only a single transmitter EE244 in between the two any desired number of routers can be installed to increase the transmission distance The...

Страница 8: ...y1 Analog output 3 1 3 Operating Components Line 1 Serial number or name of the sensing probe Line 2 Measuring value of the selected sensing probe Line 3 Serial number or name of the sensing probe Lin...

Страница 9: ...oints downwards 32 1 3 18 0 7 41 1 6 13 0 5 25 1 18 0 7 50 2 6 0 2 12 0 4 32 1 3 83 3 3 13 0 5 Installation of the housing 1 Drill the mounting holes according to the drill template see sketch There i...

Страница 10: ...na cable and relocated Antenna cable see chapter 8 Spare parts Accessories Power supply Transmitter EE244 Axx is supplied with four Alkaline 1 5V AA batteries Transmitter EE244 Bxx will accept an exte...

Страница 11: ...temperature value RH Unit for rel humidity RH 3 2 3 Operating components 1 Interval rotary switch TIME 2 Push button CONNECT To establish the initial connection between the base station and the trans...

Страница 12: ...chapter 3 2 1 Installation of a transmitter 3 3 2 Electrical Connections The router is powered by an external power supply Pin assignment of the female socket see chapter 3 2 2 Electrical Connection...

Страница 13: ...ess Network EE242 with multiple transmitters In order to register the transmitter EE244 to the network through the router the following steps have to be taken a Register the router Press the push butt...

Страница 14: ...M 5 2 Customer s Calibration of the Humidity and Temperature Sensing Probes a Calibration software on the personal computer The calibration can be done by means of software on a personal computer see...

Страница 15: ...r cap dirty Replace filter cap Wrong filter cap Replace with suitable filter cap for the application Transmitter failure Interrupted power supply or weak batteries Check the wiring of the power supply...

Страница 16: ...ea level EE244 Transmitter Router Supply transmitter EE244 A battery 4x1 5V AA Battery lifetime 1 year with a measuring data transmission every 5 min for T RH External supply transmitter EE244 B 8 28V...

Страница 17: ...ternet Explorer Mozilla Firefox and an Ethernet connection with the base station In order to setup a smooth configuration of the base station through the Ethernet network address admin authorization m...

Страница 18: ...010333 or log both in to the same network Establish power to the EE242 Start the internet browser and enter the IP address of the base station http 192 168 0 64 Enter Username and Password the followi...

Страница 19: ...functions properly Warn Alert OK Transmitters Line 1 number of active transmitters Line 2 number of active routers Line 3 total number of active transmitters and routers Base Station Line 1 model num...

Страница 20: ...transmission The transmission interval can be setup with the rotary switch TIME see chapter 3 2 3 Operating Components under 1 Interval rotary switch TIME or direct from the web server The change to...

Страница 21: ...serial number Measurand Indicates the active measurement parameter of the sensing probe temperature humidity CO2 Measured Value Last transmitted measured value More transmitter details will be listed...

Страница 22: ...ied and paste from the transmitter list see chapter 12 2 1 Transmitter List with Ctrl C and Ctrl V Transmitter Port Select the transmitter port see chapter 12 2 2 Transmitter Details under TM Port to...

Страница 23: ...desired measurement T RH Failsafe Value Output value which should be issued for a transmission error alarm Data Type Select data type Float Integer Factor Possible multiplication factor for the regis...

Страница 24: ...24 Basic settings Modbus Main menu Management Modbus Basic settings for Modbus TCP for Modbus RTU...

Страница 25: ...Mode before it can accept connection requests see chapter 4 Starting Up the Wireless System Cable Network IP address Assignment Manual static IP enter or change manually the IP address of the base st...

Страница 26: ...fo epluse cn www epluse cn E E CHINA SHANGHAI Tel 86 21 61176129 info epluse cn www epluse cn E E GERMANY Tel 49 6172 13881 0 info epluse de www epluse de E E FRANCE Tel 33 4 7472 35 82 info epluse fr...

Отзывы: