Mounting of Model F (wall mounting type with rear
cable outlet)
Transmitter EE23-xFx series are designed for wall mounting in clean room
applications. Connection cables do not disturb the cleaning process.
- working range sensor probe:
-40...60 degC (-40...140°F)
- working range electronics:
-40...60 degC (-40...140°F)
The transmitter must be mounted with the sensor probe pointed
downwards.
Mounting of Model G (wall mounting - for meteorology)
Transmitter EE23-xGx series are designed for outdoor applications.
- working range sensor probe:
-40...60 degC (-40...140°F)
- working range electronics:
-40...60 degC (-40...140°F)
For outdoor applications the transmitters must be equipped with a radiation
shield (refer to accessories). The shield causes forced ventilation which
prevents overheating of the sensor probe in direct sunlight. It also protects
the sensing probe against water of direct rainfall.
The sensor probe must point upwards and should be used in com-
bination with the radiation shield (refer to accessories).
i
≅
24VDC/AC ±15%
GND
T
RH
GND
V+
V
V
mA
mA
Versorgung /
supply
3
5
4
2
1
Analog Ausgang /
analogue output
Versorgung /
supply
≅
24VDC/AC ±15%
GND
3
T
5
T
6
T
7
T
8
RH
4
GND
2
V+
1
V
mA
Analog Ausgang /
analogue output
T-Sensor passiv /
T-Sensor passive
i
NC
13
NO
11
C
12
ON
terminal connection type EE23-FT
terminal connection type EE23-FPT
terminal connection type EE23 with
alarm output module
15
Electrical connections
1
2
3
4
5
EE23 with connectors
Euro-Norm
Euro-Norm
description:
connection assignment:
V+
5
GND
4
GND
3
RH
2
T
1
description:
connection assignment:
NC
1
COM
2
NO
3