15
Operating instructions for EE220 humidity / temperature transmitter
14 technical Data EE220
outputs
0...100 % RH
0 - 1 V
-0.5 mA < I
L
< 0.5 mA
(T output scale according to ordering code)
0 - 10 V
- 1 mA < I
L
< 1 mA
4 - 20 mA (two wire)
R
L
< 500 Ohm
T dependence of analogue outputs
max. 0.2 mV/°C
resp. 1 µA/°C
General
Supply voltage (Class III)
for 0 - 1 V output
10 - 35 V DC
or
9 - 29 V AC
for 0 - 10 V output
15 - 35 V DC
or
15 - 29 V AC
for 4 - 20 mA output
10 - 35 V DC
Load resistor for 4 - 20 mA output
R
L
<
U
v
- 10V
0.02 A
[
Ω
]
Current consumption
typ. 10 mA for DC supply
typ. 20 mA
eff
for AC supply
Electrical connection
screw terminals max. 2.5 mm
2
Cable gland
M16x1.5
cable Ø 4.5 - 10 mm
(0.18 - 0.39”)
(optional connector; type: Lumberg, RSF 50/11)
Material enclosure
PC or Al Si 9 Cu 3
Protection class enclosure
IP65 / NEMA 4
Electromagnetic compatibility
EN61326-1
EN61326-2-3
Industrial Environment
Working temperature range basic unit
-40...60 °C
(-40...140 °F)
Storage temperature range
-40...60 °C
(-40...140 °F)
For technical data EE07 and EE03 please see the corresponding data sheets at