16
UG 6980 / 02.09.16 en / 756
Function Diagram
Fault Indication by Flashing Code
Block Diagrams
simultaneity
error
Potentiometer or
adjustment failure
line fault across
start button
Cross fault or
wiring fault
M10697_a
UG 6980.04
UG 6980.02
S22
S12
ST1
t<t
On
t>t
On
t>t
diff
t<t
diff
A1/A2
13/14
23/24
38
M10703_a
max. time delay for simultaneity demand
dependent on selected safety function
E-Stop, safety gate,
t : max. 3s
Light curtais t : max. 1s
Two-hand control t : max. 0,5s
other times on request
Exclusive or contacts
diff
diff
diff
max. actuation time of start button
Standard t : max. 3s
other times on request
On
t :
diff
t :
Ein
M11034
A1+
A2
S11
RES
S12
ST1 ST2
S21
S22
23
+
13
GND
24 38
14
K1
K2
K1/K2
K2
K1
ON
monitoring logic
K1/K2
overvoltage and
short circuit protection
M11130
A1+
A2
S11
RES
S12
ST1 ST2
S21
S22
23
+
13
GND
24
38
14
K1
K2
K1-K4
K2
K1
ON
K1-K4
53
43
54
44
K4
K3
K4
K3
overvoltage and
short circuit protection
monitoring logic