background image

AR402  Administration

 

 

                    

 

 

 

 

 

 

 

 

 

  

 

 

1

 

 
 
 

 

 

 

 

 

AR402 FINGERPRINT KEY 

 

 Manual               Version 1.6 

 

 

 

 
 
 
 
 
 
 
 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

e-DATA GmbH

 

 

Содержание AR402

Страница 1: ...AR402 Administration 1 AR402 FINGERPRINT KEY Manual Version 1 6 e DATA GmbH ...

Страница 2: ... of the intended usage Any reproduction or translations of the manual beyond this or its transmission onto electronic media even in extract form is only allowed with the express permission of e DATA GmbH e DATA GmbH reserves the right to make changes to the user manual and to the devices without special notice e DATA GmbH does not accept any liability whatsoever for direct or indirect damage espec...

Страница 3: ...hnical Data 10 2 1 Mechanical Structure 10 2 2 Hardware Features 10 2 3 Biometric Sensor 10 2 4 Visual and Audible Indicators 10 2 5 Connection 10 2 6 Interface 10 2 7 Power Supply 11 2 8 Environment Conditions 11 2 9 Dimensions and Weight 11 2 10 Cable Specifications 11 3 Installation 12 3 1 Installation Requirements 12 3 2 Condition 12 3 3 Wiring 12 4 Operation 13 4 1 View of the Control Element...

Страница 4: ...Entire Database 20 5 7 Select iCLASS Mode AR402 iCLASS only 21 5 8 Define Facility Code 22 5 9 Choose 37 bit or 26 bit Format 22 5 10 Reset Manually switch to Wiegand mode 23 5 11 Reset Manually switch to RS485 mode 23 6 RS485 Configuration with NEXTOR Series Access Controller 24 6 1 Status Indication 24 6 2 Allocation of IDs on the NEXTOR Series Access Controller 24 7 Maintenance 25 7 1 Customer ...

Страница 5: ...been used in this manual Helpful tips and special characteristics of the AR402 Careful Possible danger which if the warning is not observed can result in damage to property or slight to moderate bodily injury Caution Possible danger which if the warning is not observed can result in death or serious bodily injury ...

Страница 6: ...nment Conditions 1 5 Protection Class The device conforms to the conditions of protection class IP65 Protection class III EN60950 1 Protection class IP65 DIN EN 60529 1 6 Safety Measures The device has been built according to the current and recognized technical safety rules EN60950 1 and left our manufacturing facility in perfect condition Improper handling and operation outside the specified con...

Страница 7: ...AR402 Administration 7 ...

Страница 8: ...ce may only be opened by trained specialists Disconnect the device from the power source before opening You may only perform repairs in collaboration with e DATA GmbH 1 10 CE Conformance This device is manufactured according to the safety requirements of EN 60950 Safety of electrical equipment European Norm EN 60950 This device complies with interference resistance criteria according to EN 55022 E...

Страница 9: ...led and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by ...

Страница 10: ...d Beeper 4 red green LEDs Keyboard illumination 3 Opto Inputs Wiegand output RS485 host interface 2 3 Biometric Sensor Thin optical sensor 500 dpi 8 bit per pixel Active area 0 5 x 0 9 in Template size 130 250 bytes Memory 1000 templates optionally 6000 2 4 Visual and Audible Indicators 4 red green LED user interface Beeper 3khz 2 5 Connection Cable with 11 circuits 2 6 Interface RS485 interface 1...

Страница 11: ... and Outdoor Protection class IP65 2 9 Dimensions and Weight 4 5 in x 2 5 in x 2 in H x W x D Approx 0 4 lb 2 10 Cable Specifications RS485 Shielded twisted pair cable 4000 feet max Examples 1 2x2 strands litz wire AWG24 0 4 kcmil 2 J Y ST Y 2x2x0 6 3 CAT 5 7 STP Shielded Twisted Pair Wiegand Non twisted shielded cable 500 feet max Examples 1 10 pair shielded wire AWG22 0 64 kcmil For shorter dist...

Страница 12: ...light may overheat the AR402 3 2 Condition Check the following for mounting the AR402 Device needs proper clearance All cabling must be provided electrical cable data cable and door opener cabling Power supply is provided 3 3 Wiring Do not install data cables parallel to cables conducting high voltage If unavoidable install the data cables in conduit and keep them at a distance of 1 yd to protect ...

Страница 13: ...AR402 Administration 13 4 Operation 4 1 View of the Control Elements LEDs green red 1 2 3 4 Execute Button Fingerprint Sensor Keypad Wall Mount Panel Antenna to read smart cards ...

Страница 14: ...485 Configuration Running the reader using the RS485 interface means that administration of the AR402 is done on the NEXTOR Series access controller All administrator functions except for enrollment are disabled on the AR402 Fingerprint Templates are managed by the access controller and can be distributed to the connected AR402 readers Wiegand Configuration All administrator functions described in...

Страница 15: ... green signal Indication card was read Wiegand LEDs flash Waiting for PIN entry Enter PIN Green LEDs Access granted Card plus PIN smart card Beep and short green signal LEDs 2 3 Indication card was read RS485 Green and Red LEDs 1 and 4 flash Waiting for PIN entry Enter PIN Green LEDs Access granted 4 4 3 Authentication Template on Card AR402 smart card type only Authorized users who s fingers have...

Страница 16: ...n Code 1234 In addition to the Admin Code each device has a fixed access code This code corresponds with the device s serial number a 12 digit hexadecimal code which is printed on the back of the reader The 12 digit code serves as a basis for calculating the access code if your Admin Code is lost In this case please contact e DATA GmbH 5 1 Change the Admin Code The default Admin Code is 1234 For s...

Страница 17: ...1 2 3 4 flashing Enter User ID xxxxx Green 1 flashing Sensor Red Apply 2 Fingers 3x if successful Green 1 2 3 4 flashing Finalize by 1 x or wait for Timeout Entering a User ID with an incorrect number of digits an already existing User ID or variant IDs with Validation enabled and also if your fingers already have been scanned will prompt an error message all red LEDs flashing three times and caus...

Страница 18: ...o the controller Template on Card may be expedient where storing biometric data is prohibited In addition this mode offers a good alternative using biometric readers in a Wiegand configuration as users will not have to enroll on multiple readers At this point Template on Card only works with 16K2 iCLASS cards and in a Wiegand configuration The AR402 iCLASS will store the fingers of a new user onto...

Страница 19: ...mber of Digits for User ID 16 Green 3 4 flashing Beep Default 5 2 9 digits if successful Green 1 2 flashing Beep Finalize by 3 x or wait for Timeout 5 4 Enable Validation of the User ID optional This menu allows you to enable the validation of the User ID for enrollment to eliminate incorrect entries Admin Mode 99 Green 1 2 Default Admin Code 1234 or enter your Admin Code xxxx Green 1 2 3 Function...

Страница 20: ... 3 4 flashing Beep Optional More User IDs xxxxx Green 1 2 3 4 flashing Beep Finalize by 3 x or wait for Timeout 5 6 Delete Entire Database Caution Admin Mode 99 Green 1 2 Default Admin Code 1234 or enter your Admin Code xxxx Green 1 2 3 Enter Delete Database 1357 Red 1 2 3 4 flashing Beep Press key to confirm if successful Green 1 2 3 Beep Finalize by 3 x or wait for Timeout If you see red LEDs af...

Страница 21: ...e or to enable the Template on Card mode instead cp Enrollment with Template on Card enabled page 18 Admin Mode 99 Green 1 2 Default Admin Code 1234 or enter your Admin Code xxxx Green 1 2 3 Function Menu 14 Green 1 2 flashing Beep iCLASS Menu 24 Green 3 4 flashing Beep Enable iCLASS Default 1 Green 1 2 flashing Beep or Enable Template on Card 2 Green 1 2 flashing Beep or Disable iCLASS 0 Green 1 ...

Страница 22: ...7 bit or 26 bit Format These settings only apply to the trigger signal of the reader s biometric sensor sent to the access controller The Facility Code of iCLASS cards is sent to the access controller untouched and independent of these settings In a Wiegand configuration the format of the biometric sensor s trigger signal to the access controller can be defined e g Set the biometric sensor s forma...

Страница 23: ... your Admin Code xxxx Green 1 2 3 Enable Wiegand Mode 1 Device resets to all defaults and reboots 5 11 Reset Manually switch to RS485 mode This function allows you to manually set the AR402 to RS485 mode All settings will be reset The reader indicates its offline status by the red flashing LED 4 The AR402 will automatically go online once it is connected via RS485 to a controller of the NEXTOR ser...

Страница 24: ...and 3 flashing red 6 2 Allocation of IDs on the NEXTOR Series Access Controller On a RS485 data bus the devices are distinguished by a device ID address The NEXTOR Series access controller recognizes serial numbers of AR402 readers on the bus line These serial numbers are 12 digit hexadecimal codes e g C03859110000 printed on the back of the readers The access controller assigns the two reader IDs...

Страница 25: ...ustomer details What troubleshooting steps have you already taken to correct the error LED status Device and controller errors What occurred before the error 7 2 Repairs Careful You may only undertake repair work after coordination with e DATA GmbH International 7 3 Warranty Limitation on Liability to Third Parties In accordance with national statutory regulations at the place where the device is ...

Страница 26: ... FAR FRR adjustable Sensor Thin optical sensor 500 dpi 8 bit per pixel Active area 55 x 87 in 14mm x 22mm Templates Template Size 130 to 250 bytes Storage Capacity 1000 or 6000 templates by model not valid for template on card Power 12 bis 24V DC 67mA 160mA Operating Temperature 14 to 122 F 10 to 50 C Relative Humidity 0 to 95 Mechanical NEMA IP65 rated Metal Mounting Plate Resin sealed hard plast...

Страница 27: ...gits 16 Default 1234 24 Select iCLASS Mode AR402 iCLASS only 21 Default 1 0 disabled 1 enabled 2 enable Template on Card 16 Define the Number of Digits for the User ID 2 9 digits 19 Default 5 22 Enable Validation of the User ID 19 Default 0 0 disabled 1 enabled 19 Choose 37 bit or 26 bit Format 22 Default 0 0 37 bit 1 26 bit 20 Define Facility Code 22 Default 830 0 65535 37 bit Optional Default 1 ...

Страница 28: ...old 00 10 2 digits with leading zeroes 10 recognition threshold is highest default 5 8 2 Allocation of the Cable Connectors on the Door Unit Color Purpose RS485 Wiegand tan Tamper Switch 2 pink RS485A X38 X39 3 grey RS485B X38 X39 2 Red DC in 12 24V X36 X37 X36 X37 Black DC in X36 X37 X36 X37 White Wiegand Out D1 X38 X39 2 green Wiegand Out D0 X38 X39 3 violet Wiegand Ground X38 X39 1 brown Green ...

Страница 29: ... pair AWG24 0 4 kcmil Consider whether or not to supply power with the data cable Long distances require an increased gauge of cable Supplying power locally or having an extra power cable pull may be preferable Because of voltage drop over longer distances use of a 24V power source is the recommended choice Example for calculating the power supply wiring 1 AWG22 cable 0 34 mm2 Loop resistance ca 1...

Страница 30: ...AR402 Administration 30 ...

Страница 31: ...AR402 Administration 31 ...