Document:
Date
Created By:
ECO#
LPN00322X0002A1_A
2017-10-30
TMT
008443
INSTALLATION INSTRUCTIONS
E-SBA7 Series
www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409
Note:
Only use Adjustable U-bracket kit (E-ACUSB). Use this fixture
installation sheet for installing. DO NOT refer to mounting accessory
sheet for installing.
1.
Remove the six screws on the top of the fixture housing to allow
removal of the driver housing cover plate.
2.
Attach U-bracket to fixture as shown in
Figure 3.
Make sure
sealing washers are under bolt heads.
3.
Pass bolts from inside of housing through housing wall and
U-bracket.
4.
Slide (2) lock washers over yoke bolts.
5.
Secure U-bracket to housing with (2) 5/16" nuts. Tighten nuts to
132 in-lbs (15 N•m).
6. Insert cord through cord grip so that the leads extend from the
threaded end of the cord grip by approximately 4". Tighten cord
grip firmly to cord.
7.
Remove nut from cord grip. Pass threaded end of cord grip
through wall of housing. Make sure gasket for cord grip is on
outside of housing.
8.
Tighten nut on threaded end of cord grip to secure cord grip to
housing. Do not overtighten to prevent damage to threads.
9.
Connect the driver voltage (black) lead to the black cord lead.
Connect the driver common (white) lead to the white cord lead.
Connect the green fixture lead to the green cord lead.
10. Mount fixture using (2) 3/8" (10mm) bolts appropriate for mounting
surface. See
Figure 4.
11.
Reinstall driver housing cover plate by placing it on top of housing
and tightening the (6) screws that were removed in Step 1.
12. Make wire connections to supply leads. Connect the black cord
lead to the voltage supply lead. Connect the white cord lead to the
neutral supply lead. Connect the green cord lead to the ground
supply lead.
1.
Adjust fixture to desired angle, making sure to line up set of
locking holes in inner and outer yoke brackets.
2.
Insert locking screw into matching holes of inner and outer yokes,
and tighten.
3.
Securely tighten both bolts on sides of U-bracket.
Note:
Only use 6" Mounting Arm kit (E-ACESB). Use this fixture
installation sheet for installing. DO NOT refer to mounting accessory
sheet for installing.
Note:
Strain relief is required for electrical connections at height of
25' (7.6 mm) and above. Knot the supply wires from the pole with the
fixture cord inside the pole.
1.
Use template on last page for dimensions on pole drilling if pole is
not pre-drilled. NOTE: Template is not to scale.
2.
Remove the (6) screws on the top of the fixture housing to allow
removal of the driver housing cover plate.
3.
Screw threaded rods through holes in pole into backing plate
inside pole until non-threaded section of rod contacts backing
plate. See
Figure 5.
4.
Insert cord through cord grip so that the leads extend from the
threaded end of the cord grip by approximately 4”. Tighten cord
grip firmly to cord.
5.
Remove nut from cord grip. Pass threaded end of cord grip
through wall of housing. Make sure gasket for cord grip is on
outside of housing.
6. Tighten nut on threaded end of cord grip to secure cord grip to
housing. Do not overtighten to prevent damage to threads.
7.
Connect the driver voltage (black) lead to the black cord lead.
Connect the driver common (white) lead to the white cord lead.
Connect the green fixture lead to the green cord lead.
U-BRACKET MOUNTING
TO AIM FIXTURE (U-BRACKET)
6" MOUNTING ARM
8.
Feed cord through extrusion into pole and slide extrusion over
threaded rods so that the rods are positioned in extrusion
channels.
9.
Align mounting holes of fixture with exposed ends of threaded rods
and push fixture flush with extrusion.
10. Install sealing washers and nuts onto threaded rods inside fixture.
See
Figure 5.
11.
Torque hex nuts to 132 in-lbs (15 N•m).
12.
Reinstall driver housing cover plate by replacing it on top of
housing and tightening the (6) screws removed in Step 2.
13. Make wire connections inside pole. Connect the black cord lead
to the voltage supply lead. Connect the white cord lead to the
neutral supply lead. Connect the green cord lead to the ground
supply lead.
FIGURE 4 — Mounting to Surface
Inner Trunion
(Assembles to the Housing)
Adjustment Screw and Holes
Lock Washer
between Trunions
Outer Trunion
Sealing Washers
Cord Grip
Align these
Two Trunion Holes
Housing
(Cross Section View)
Hex Nuts
Hex Bolts
Cord
Lock
Washers
Gasket for
Cord Grip
Nut for
Cord Grip
FIGURE 3
Extruded Arm
Cord
Pole Cap
Backing
Plate
Pole
Threaded
Rod
Hex Nut
Sealing Washer
FIGURE 5