INSTALLATION INSTRUCTIONS

LED TRACK HEAD

E-KCN SERIES

2017-9-25

www.e-conolight.com      |     888.243.9445     |     FAX: 262.504.5409

1. 

To install track fixture into lower circuit of two-circuit track, 

follow directions for single circuit installation.

2. 

To install track fixture into upper circuit of two-circuit track, 

raise the Brass Contact labeled “P” by grasping Contact with 

needle nose pliers and pulling up into position. See 

Figure 3.

3. 

Insert Contact Support by tipping and positioning it under the 

“P” Contact. See

 Figure 3.

 Snap Contact Support in place.

NOTE: 

Once the contact support is in place, make sure the 

“P” contact is fully seated in the support by using the needle 

nose pliers to push the “P” contact into place.

4. 

Refer to instructions 1-3 under “Fixture Installation on Single 

Circuit Track” section.

CAUTIONS

DIMMING INFORMATION

For a list of approved dimmers visit www.e-conolight.com

1. 

Insert Brass Contact on top of Track Adaptor into the Track 

Channel. See 

Figures 1 and 3.

2. 

Rotate the Track Adaptor 90° so that the Indicator Arrows 

point toward the Polarity Groove once installed. See 

Figure 2.

 Pull Adaptor Latch down as you rotate Track 

Adaptor in order for Latch to clear track edge and allow it 

to snap into place in the track.

3. 

To remove or relocate track fixture location, pull Adaptor 

Latch down, rotate the Track Adaptor 90° away from the 

Polarity Groove and remove.

FIGURE 1

Notes:

1. 

All E-conolight Track sections are manufactured with a 

Polarity Groove.

2. 

All E-conolight Track fixtures are manufactured with 

Indicator Arrows designed to point toward the Polarity 

Groove once installed. See 

Figures 1-2.

3. 

E-conolight Track fixtures are UL® Classified for use 

with E-conolight E-K1 and E-K2 Series, Ruud T1 and 

T2 Series, and Juno® (not affiliated with E-conolight or 

Ruud) T and TU Series track systems only.

4. 

All E-conolight Track fixtures are supplied with a Contact 

Support to convert fixture from Single Circuit installation 

to Two Circuit Installation. 

See Figure 3

FIXTURE INSTALLATION – SINGLE CIRCUIT 

TRACK

FIXTURE INSTALLATION – TWO CIRCUIT 

TRACK

Track Adapter

Indicator Arrows

Luminaire

Movable Brass

Contact “P”

FIGURE 2

FIGURE 3

Plastic

Insulator

Polarity

Groove

Copper

Conductors

Aluminum Track

Extrusion

Contact

Support

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should 

always be followed including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant 

l’installation.

2. 

This luminaire must be installed in accordance with the NEC 

or your local electrical code. If you are not familiar with these 

codes and requirements, consult a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code 

électrique local. Si vous n’êtes pas familier avec ces codes et 

ces exigences, veuillez contacter un électricien qualifié.

 

3. 

Min 90°C supply conductors.

Les fils d’alimentation 90°C min.

4. 

Wait until fixture has cooled down before installing or servicing 

the fixture.

5. 

Please read and understand all instructions thoroughly before 

installing any part of the Track system.

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE 