CAUTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER

 – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This luminaire must be installed in accordance with the 

NEC or your local electrical code. If you are not familiar 

with these codes and requirements, consult a qualified 

electrician. 

Ce produit doit être installé conformément à NEC ou votre 

code électrique local. Si vous n’êtes pas familier avec ces 

codes et ces exigences, veuillez contacter un électricien 

qualifié.

3.  Suitable for Wet Locations.

Adspte pour les Endroits Mouiles.

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE 

NOTES

1.  This carton contains fixture, anchor bolts and mounting 

template. See reverse side for not-to-scale mounting 

template.

FOUNDATION

1. 

Foundation should be a minimum of 12 inches (305 mm) in diam-

eter, finished level and smooth, with a depth below grade of 24 (610 

mm) inches.  NOTE: in areas where frost is imminent, consult with a 

civil engineer for a recommended foundation detail.

2.   Provided are three 3/8” diameter x 11” (352 mm) long anchor bolts 

and mounting template (included). Use template to set anchor bolts 

at proper location (Note conduit entry allowance).  Anchor bolts 
should project 2” (51 mm) above concrete.

NOTE: Lens assembly does not need to be removed from 

bollard pole during installation process.

1.  To install bollard pole to anchor bolts, loosen four 1/4-20 set screws 

at base of pole using a 1/8" Allen wrench.

2.  Begin lifting pole and lens assembly vertically off base. When wiring 

quick disconnect is exposed, unlatch two halves of quick disconnect 

and set pole/lens assembly aside.

3.  Install base plate and inner frame assembly over anchor bolts and 

secure with nuts, washers, and jam nuts provided.

NOTE:

 If leveling of the base is required, leveling nuts should be 

used. Do NOT use shims.

4.  Make electrical supply connections to terminal block on inner frame 

assembly. See Electrical Connection section for proper wiring.

5.  Reconnect two halves of quick disconnect from Step 2 and slide 

pole/lens assembly over interior frame and base. Be careful not to 

pinch any lead wires.

NOTE:

 Position pole so that 1/4-20 set screws align with circular 

indentations in base.

6.  Tighten four 1/4-20 set screws to secure pole/lens assembly to base.

 

Fixture is equipped with universal volt driver 120-277V 

(ie. 120V, 208V, 240V or 277V)

PHASE TO NEUTRAL WIRING 120/277V

1.  Connect supply ground to fixture ground (green) lead.
2.  Connect supply common to fixture neutral (white) lead.
3.  Connect supply Vin to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no 

wires are pinched.

PHASE TO PHASE WIRING 208/240V

1.  Connect supply ground to fixture ground (green) lead.
2.  Connect supply L1 (Hot) to fixture neutral (white) lead.
3.  Connect supply L2 (Hot) to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no 

wires are pinched.

 

CAUTION:

 Changes or modifications not expressly approved could void 

your authority to use this equipment. 

This device complies with part 15 of the FCC Rules. Operation is subject 
to the following two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area 
is likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.
CAN ICES-003 (A)/NMB-003 (A)

ELECTRICAL CONNECTIONS

FCC NOTICE

BOLLARD INSTALLATION

Содержание E-BBA series

Страница 1: ...eveling of the base is required leveling nuts should be used Do NOT use shims 4 Make electrical supply connections to terminal block on inner frame assembly See Electrical Connection section for proper wiring 5 Reconnect two halves of quick disconnect from Step 2 and slide pole lens assembly over interior frame and base Be careful not to pinch any lead wires NOTE Position pole so that 1 4 20 set s...

Страница 2: ...STALLATION INSTRUCTIONS E BBA Series www e conolight com 888 243 9445 FAX 262 504 5409 120 120 3 76 mm dia hole available conduit entry 5 75 146 mm dia bolt circle 391 10 mm dia hole 3 required 3 Anchor Bolts 3 8 16 x 11 1 25 Double Nut Bolt Projection 2 51 mm NOT TO SCALE ...

Страница 3: ... nivelar la base se deben usar tuercas de nivelación NO use cuñas 4 Realice las conexiones del suministro eléctrico al bloque de terminales en el conjunto del marco interior Consulte la sección Conexión eléctrica para ver el cableado correcto 5 Vuelva a conectar dos mitades de desconexión rápida del paso 2 y deslice el conjunto de polo lente sobre el marco interior y la base Tenga cuidado de no pe...

Страница 4: ...A www e conolight com 888 243 9445 FAX 262 504 5409 120 120 Diámetro del orificio 3 76 mm Entrada de conducto disponible Diámetro del círculo del tornillo 5 75 146 mm Diámetro del orificio 0 391 10 mm se requieren 3 3 Tornillos de anclaje Doble tuerca de 3 8 16 x 11 1 25 Proyección del tornillo 2 51 mm NO A ESCALA ...

Страница 5: ...eur Voir la section Branchements électriques pour le câblage approprié 5 Reconnectez deux moitiés de déconnexion rapide de l étape 2 et faites glisser l ensemble poteau lentille sur le cadre intérieur et la base Veillez à ne pas pincer les fils conducteurs REMARQUE Positionner le poteau de façon à ce que les vis de réglage 1 4 20 s alignent avec les entailles circulaires dans la base 6 Serrez quat...

Страница 6: ...light com 888 243 9445 TÉLEC 262 504 5409 120 120 Diamètre de trou 76 mm 3 po entrée de conduit disponible Diamètre de cercle de perçage 146 mm 5 75 po Diamètre de trou 10 mm 0 391 po 3 requis 3 Boulons d ancrage 0 95 cm 3 8 po 16 x 28 cm 11 po écrou double de 3 18 cm 1 25 po Saillie de boulon 51 mm 2 po NON À L ÉCHELLE ...

Отзывы: