PROTEUS 

PROTEUS 

PROTEUS 

PROTEUS  PROTEUS  PROTEUS 

Product type

Unit PREMIX 14 PREMIX 20 PREMIX 24 PREMIX 28 PREMIX 30 PREMIX 35

 HM-HCH-

 HM-HCH-

 HM-HCH-

 HM-HCH-  HM-HCH-  HM-HCH-

HST 

HST 

HST 

HST 

HST 

HST 

Gas Category

I2H, I3P, I2Esi, I2E(S), II2L3P, II2H3P, II2ELL3P, II2Esi3P

Flue Types

C

13

(X), C

33

(X), C

43

(X), C

53

(X), C

63

(X), C

83

(X), B

23

, B

33

Gas Input Pressure (G20)

mbar

20

Gas Input Pressure (G25)

mbar

20

25

Gas Input Pressure (LPG G31)

mbar

37

50

Capacity-Efficiency

Min. Heating power - (@60°C min) 

kW

5,6

5,6

5,6

6,4

6,9

8

Max. Heating power  - (@80

60°C) (P4)

kW

14,1

20,2

24,5

28

30

35

Min. Heating power - (@30°C min) 

kW

6,7

6,7

6,7

7,7

8,3

9,6

Max. Heating power- (@50

30°C) 

kW

15

22,2

26

29,6

31,7

37

Min. Heat input  (Qn)

kW

6,2

6,2

6,2

7,2

7,7

9

Max. Heat input (Qn)

kW

14,5

20,7

25,2

28,7

30,8

35,9

Efficiency (@80°

60° C  Max) (Gross 

Calorific value)

%

97,50%

97,50%

97,50%

97,50%

97,50%

97,50%

Efficiency (30°C Return) (Gross 

Calorific value)

%

107,50%

107,50%

107,50%

107,50%

107,50%

107,50%

ERP Informations

Seasonal Space Heating Energy 

Efficiency Class

A

A

A

A

A

A

Water Heating Energy Efficiency Class

 

Load Profile

A

XL

A

XL

A

XL

A

XL

A

XL

A

XL

Rated Heat Output (Prated)

kW

20,2

20,2

24,5

28

30

35

Seasonal Space Heating Energy 

Efficiency 

%

91,11

91,4

92,2

92,4

92

92,9

Water Heating Energy Efficiency

%

83,6

83,6

83,6

83,9

82,8

82,8

Sound Power Level 

db(A)

49

49

49

49

49

49

Efficiency at Rated Heat Output At 
High Temperature Regime (

ƞ

4

)

%

87,9

87,9

87,9

87,9

87,9

87,9

Efficiency at 30% of rated Output At 
Low Temperature Regime (

ƞ

1

)

%

97

97

97,2

97,4

97

97,9

At Full Load elmax

kW

0,028

0,035

0,04

0,051

0,056

0,066

At Part Load elmin

kW

0,012

0,012

0,012

0,012

0,013

0,013

In standby Mode

kW

0,004

0,004

0,004

0,004

0,004

0,004

Standby Heat Loss

kW

0,065

0,065

0,065

0,065

0,065

0,065

Emissions of Nox Level

mg

k

Wh

25,91

27,2

25,91

21,29

25,91

25,91

Daily Electricity Consumption (Qelect) kWh

0,423

0,423

0,194

0,22

0,24

0,24

Daily Fuel Consumption (Qfuel)

kWh

22,88

22,88

22,8

22,8

23,021

23,021

Gas Consumption

Natural Gas (@Min-Max Capactiy)

m

3

h

0,65-1,53

0,65-2,2

0,65-2,65

0,75-3,02

0,81-3,25

0,94-3,79

LPG (@Min-Max Capactiy)-Propane

kg

h

0,51-1,2

0,51-1,7

0,51-1,98

0,59-2,26

0,63-2,46

0,74-2,87

NO

X

 Class

6

6

6

6

6

6

Central Heating

Min. Water Pressure

bar

0,4

0,4

0,4

0,4

0,4

0,4

Max. Water Pressure

bar

3

3

3

3

3

3

Operation Range (@Radiator heating)

o

C

30-80

30-80

30-80

30-80

30-80

30-80

Operation Range (@Underfloor 

heating)

o

C

30-45

30-45

30-45

30-45

30-45

30-45

Max. Limit temperature

o

C

> 90

> 90

> 90

> 90

> 90

> 90

4- TECHNICAL DATA

7

Содержание PROTEUS PREMIX 14 HM NG ERP UK

Страница 1: ...3527 86 35 0 0 67 3527 86 35 0 21 16 1 2 5 23 5 7 1 167RUCTIONS...

Страница 2: ...mbi Boiler in Terms of Safety and Energy Consumption 3 2 Clogging in Installation 3 3 Cleaning of Boiler 3 4 Boiler Features 3 5 Additional Recommendations by ECA to Customer To Have High Heating Perf...

Страница 3: ...stalled in accordance with national and local requirements gas safety regulations relevant standarts and this manual by gas safe engineer 9 The boiler must be mounted against a closed wall 9 The boile...

Страница 4: ...centralheating co uk or installersfirst co uk for more information PRODUCT NAME PRODUCT CODE GC NUMBER PROTEUS PREMIX 14 HM NG ERP UK 8116941010 47 814 30 PROTEUS PREMIX 20 HM NG ERP UK 8116944010 47...

Страница 5: ...tial start up of the boiler Instructions are given below 9 Check Operating Instructions Installation and Maintenance Instructions and follow instructions before installation 9 Carry out installation i...

Страница 6: ...unauthorized service or staff 3 4 Boiler Features Control panel is ergonomic and easy to use The Proteus Premix condensing boiler with elegant plastic control panel and advanced LCD screen provides ea...

Страница 7: ...5 Seasonal Space Heating Energy Efficiency 91 11 91 4 92 2 92 4 92 92 9 Water Heating Energy Efficiency 83 6 83 6 83 6 83 9 82 8 82 8 Sound Power Level db A 49 49 49 49 49 49 Efficiency at Rated Heat...

Страница 8: ...pansion Vessel lt 8 Weight Net kg 28 5 28 5 28 5 30 30 32 Weight Net only for HCH model kg 22 5 22 5 22 5 24 24 26 Dimesions HxWxD mm 678 410 288 Flue Lenghts C13 60 100 Max m 10 10 10 10 10 10 C13 80...

Страница 9: ...49 Specific precautions for assembly installation and maintanence All specific precautions for installation assembly and maintanence are described in the installation and service manual Proteus Premi...

Страница 10: ...on from fiche of solar device III The value of the mathematical expression 294 11 Prated whereby Prated is related to the preferential space heater IV The value of the mathematical expression 115 11 P...

Страница 11: ...in this fiche may not correspond to its actual energy efficiency once installed in a building as this efficiency is influenced by further factors such as heat loss in the distribution system and the...

Страница 12: ...dimensioning of the products in relation to building size and characteristics I The value of the water heating energy efficiency of the combination heater expressed in II The value of the mathematica...

Страница 13: ...Comfort mode Once the Reset button is pressed when operating in Comfort mode the boiler will switch to Eco mode Then when Reset button is pressed again the unit will switch to Comfort mode C Domestic...

Страница 14: ...omestic hot water is heating request the tap symbol flashes 1 time sec In this mode the domestic hot water temperature can be adjusted between 30 65 C 7 3 5 Comfort Mode The standard operating mode of...

Страница 15: ...is still present or persists after reset notify gas safe engineer 1 Press reset button 2 If the error is still present or persists after reset notify gas safe engineer 1 Check that water valves of boi...

Страница 16: ...hen the temperature of the flue gas exceeds 95 o C F07 1 Notify gas safe engineer F13 Repeated Reset Fault Pressing of Reset button more than 5 times in an hour 1 Notify gas safe engineer F25 Electron...

Страница 17: ...ue gas The flue gas temperature sensor is in short or open circuit state F53 1 Notify gas safe engineer Flue Gas Lock Out at High Temperature If it gives an error F07 twice in 1 month this error will...

Страница 18: ...ny third party who undertakes any work carried on the product or fits parts unless approval is given by the means mentioned in point 5 such work in advance of it being carried out 7 The boiler has to...

Страница 19: ...hen be debited from your account i You are required to provide telephone contact numbers to enable us to contact you in the course of arranging and fulfilling your appointment In the course of arrangi...

Страница 20: ...si 3 K s m Mustafa Kemal Bulvar No 13 45030 MAN SA 90 236 213 00 21 SALES TECHNICAL SUPPORT Call Center Tel 44 800 640 9988 Office Tel 44 203 978 1212 FW YDW QJ RXU TXDUDQWHH V TX FN DQG V PSOH EXW UH...

Отзывы: