background image

FELIS

WALL HUNG CONDENSING BOILER
FELIS 

FL 

50/

65/

100

/12

5

/1

5

0

 HM

INSTALLATION AND

USER MANUAL

Содержание FELIS FL 100 HM

Страница 1: ...FELIS WALL HUNG CONDENSING BOILER FELIS FL 50 65 100 125 150 HM INSTALLATION AND USER MANUAL ...

Страница 2: ......

Страница 3: ... ProductFeatures 4 I Product Notation and Technical Dimensions 5 I Detailed Drawings and List of Components 6 I Technical Specification Table 9 I Packaging 11 11 17 I 17 I 19 I 19 I INSTALLATION and CONNECTIONS OPERATING ControlPanel Date Time Settings Time Programs Working Modes 20 26 31 32 ERROR FAULT CODES MAINTENANCE STANDARDS REGULATIONS CONNECTION SCHEMAS ERP PRODUCT FICHES EC DECLARATION OF...

Страница 4: ...tilizing your boiler s complete features and to use your appliance safely for a long time please read the manual carefully Please keep all the documents that come with your appliance for future reference This appliance conforms the related regulations about the limitation of hazardous materials in electric and electronic devices Does not contain polychlorinated biphenyl asbestos or mercury All rep...

Страница 5: ...n using these chemicals please follow the instructions Any dirt blockages welding residuals burr flug etc particules left inside the pipes will affect the boiler s performance These residuals will cause boiler to overheat noisy operating etc Any damage or failure caused by unfit piping system is out of warranty coverage INFORMATION If there is a natural gas smell SAFETY RULES SAFETY RULES AND WARN...

Страница 6: ...lid underneath the appliance First startup of the appliance must be done by the authorized service Natural gas usage must be approved by the related gas company prior to the first startup The gas type natural gas inlet gas pressure mbar maximum water pressure bar and electrical nominal voltage V values on the information label must be checked with the local conditions To prevent the risk of flue g...

Страница 7: ...tem that supports multiple languages with descrpitive menus White backlighted LCD screen shows information about working mode CH and DHW set points real time temperatures fault codes with descriptions and water pressure Safety measurements on the appliance assures both your safety and the safety of the appliance These safety measurements are as follows Flame Loss Safety CH Circuit Overheating Safe...

Страница 8: ...tion Lid Siphon Connection Lid Dimensions A B C D E Ø F Ø G Ø H Ø I Felis FL 50 HM DG 501 mm 835 mm 525 mm 145 mm 304 mm 80 125 mm 1 1 4 1 1 4 3 4 Felis FL 65 HM DG 501 mm 835 mm 590 mm 145 mm 304 mm 80 125 mm 1 1 4 1 1 4 3 4 Felis FL 100 HM DG 501 mm 835 mm 590 mm 145 mm 304 mm 100 150 mm 1 1 4 1 1 4 1 Felis FL 125 HM DG 501 mm 835 mm 660 mm 145 mm 304 mm 100 150 mm 1 1 4 1 1 4 1 Felis FL 150 HM ...

Страница 9: ...TC TEMP SENSOR OUTLET 13 CONDENSATION HOSE 4 IGNITION TRANSFORMER 14 BOILER OUTLET PIPE HOT 5 HEAT EXCHANGER 15 BOILER INLET PIPE COLD 6 AIR PURGER 16 HEAT EXCHANGER HANGING BRACKET 7 FLUE GAS SENSOR 17 MIXER 8 IGNITION AND IONIZATION ELECTRODE 18 NTC TEMP SENSOR INLET 9 BACKFLOW PREVENTER 19 GAS INLET PIPE 10 BLOWER 6 Figure 2a Felis 50 Detailed Drawings ...

Страница 10: ...7 Felis 65 Figure 2b Felis 65 Detailed Drawings ...

Страница 11: ...8 Felis 100 125 150 Figure 2c Felis 100 125 150 Detailed Drawings ...

Страница 12: ...6 4 84 3 87 8 87 1 87 5 Efficiency 30 Output at Low Temperature Regime ɳ1 97 2 97 5 97 4 97 1 97 2 Electrical Consumption at Full Load elmax Watt 75 115 139 226 297 Electrical Consumption at Part Load elmin Watt 16 22 33 35 27 Electrical Consumption at Standby Psb Watt 4 4 4 3 4 Standby Heat Loss Pstby kW 0 411 0 939 1 564 0 644 1 6 Yearly NOx Emissions mg kWh 37 82 28 13 26 4 42 91 34 06 Space He...

Страница 13: ...Figure 3 Electronic Board Circuit Diagram 10 Electrical Board Circuit Diagram ...

Страница 14: ...sure It must be connected to a heating circuit suitable for its capacity and nominal output Felis boilers are suitable with flue types C13 x C33 x C43 x C63 x and C93 x therefore its flue system is seperated from the ambient air Even though in case of a gas leak the boiler room must be equipped with the required ventilation equipment Under hermetic working coaxial flue is in contact with the fresh...

Страница 15: ... service maintenance and usage spaces required around the appliance is indicated in Figure 5 E C A Felis condensing boiler must be hung to a brick wall with the supplied hanging bracket For installation Take measurement from the back side of the boiler to make sure that the holes are in line and horizontal Mark the hole places on the wall Drill the holes and put in the wall plugs Fix the hanging b...

Страница 16: ...te water outlet to prevent the flue gas to leak into the surrounding air Galvanised and copper alloy parts should not be used in the pipes and connection parts all parts of condensate drain should be in plastic If the drain hose would be connected to a drain out of the building isolating the hose might be necessary to prevent the hose to freeze For a good operation all horizontal parts of the cond...

Страница 17: ...ess gaskets should be mounted correctly to prevent flue gas leakage to the fresh air intake Horizontal flue kit must be installed with a 3 slope towards the appliance to keep the condansate water flowing Different connection kits for the air intake and flue outlet are provided seperately You can use the Felis condensing boiler as a B type device with a flue adapter that you can supply from your se...

Страница 18: ... d d l Figure 7 Flue Types 15 I I I I ...

Страница 19: ...mostats can be used for heating control of the system Figure 8a Figure 8c E C A On Off Room Thermostat Wireless 7006907522 Wired 7006907519 Figure 8d Figure 8b E C A On Off Room Thermostat T6360 7006901312 AF18 Room Unit 7006721436 AF17 Digital Room Unit 7006721435 ...

Страница 20: ... of the appliance and system with its wide LCD screen and multi language support while allowing full control on the appliance Figure 9 Felis Control Panel and Buttons By pressing Info button user can see values such as Boiler temperature Outside Temperature Room Temperature Water Pressure Authorized Service Telephone No etc OPERATING Figure 10 Felis Control Panel Information In particular instance...

Страница 21: ...an be manually reset from the reset button on the slave appliances For more information please refer to Cascading Applications section of this manual 18 Figure 11 User Interface for Slave Appliances Wide LCD screen located on the control panels gives various informations about working mode menu level heating circuit number maintenance and error statuses Meanings of the symbols appearing on the scr...

Страница 22: ... time program and parameters 501 506 decides the times of the day for the heating to switch on and off You can see the arranged time program as a line chart in the bottom of the LCD screen TIME PROGRAMS You can program the desired time slots for the appliance to run from the control panel These settings can be done for weekdays Mon Fri weekends Sat Sun all week Mon Sun or seperate for each day For...

Страница 23: ...tive Automatic summer winter changeover ECO functions and 24 hour heating limit inactive in the case of continuous operation with Comfort setpoint Continuous operation When using protection mode the heating system is off but it remains protected against frost frost protection temperature provided there is no power failure Characteristics of Protection mode Heating off Temperature according to fros...

Страница 24: ...ower outside temperatures If you can t achieve desired room temperature heating curve slope must be adjusted Increasing the slope increases water temperature in lower outside temperatures Decreasing the slope decreases water temperature for the same outside temperature value Figure 16 Heating Curves for 20 C Comfort Setpoint 21 P No Description ID1 710 712 714 720 726 ID2 1010 1012 1014 1020 1026 ...

Страница 25: ...grams After activating manual operation mode pressing Return button goes back to main screen When maintenance special operation symbol appears on the screen user can press Info button to change to the manual operation screen and change the manual operation setpoint Domestic Hot Water Selecting the Domestic Hot Water Mode Domestic hot water DHW tank mode selection button is located on the upper lef...

Страница 26: ...f the Frost Protection setpoint applies Time program 4 DHW When using this setting a specific time program is available for DHW heating For every weekday a time program with a maximum of 3 on phases can be set During the release time the Nominal DHW setpoint applies outside the release time the Reduced DHW setpoint If the Legionella function is pending it will be performed when DHW heating is rele...

Страница 27: ...ay 1642 When using this setting heating up to the Legionella setpoint takes place on the selected weekday independent of previous storage tank temperatures This setting is intended primarily for plant without solar integration Legionella function setpoint The Legionella setpoint can be adjusted between 55 C and 95 C When the Legionella function is activated the DHW storage tank is heated up until ...

Страница 28: ...ctive in Automatic operation In the other operating modes they are started and run in the background to become active whenever Automatic operation is selected When a holiday period has elapsed the controller automatically deletes it The same holiday period the following year would have to be reprogrammed A holiday period starts at 0 00 of the first day and ends is deleted at 24 00 of the last day ...

Страница 29: ...nconsistencies occured during these controls will be shown as error and fault codes on the LCD screen and will be indicated with a bell sign on the upper left Some detailed information for the possible error fault codes is provided in the following table ERROR FAULT CODES Figure 19 Error Fault Codes ...

Страница 30: ...27 ...

Страница 31: ...28 ...

Страница 32: ...29 ...

Страница 33: ...30 ...

Страница 34: ...sing any chemical substances Usage of chemicals like detergents etc could cause rust and scratches ALL RIGHTS RESERVED Our company reserves the right to make changes on the products installation and user manuals STANDARDS REGULATIONS In addition to the warnings and instructions detailed in this manual all laws regulations standards and local gas company instructions regarding the gas burning appli...

Страница 35: ...105 mm 235 mm 65 mm 240 mm 330 mm 435 mm 1 SIPHON 2 CH RETURN 1 3 4 CH FLOW 1 GAS 5 FLUE Ø80 125mm 1 2 3 4 2 1 3 4 145 mm 220 mm 5 5 FELIS 50 kW CIRCUIT AND FLUE CONNECTIONS 32 ...

Страница 36: ...105 mm 260 mm 65 mm 240 mm 435 mm 445 mm 1 SIPHON 2 CH RETURN 1 3 4 CH FLOW1 GAS 5 FLUE Ø80 125mm 1 2 3 4 2 1 3 4 145 mm 220 mm 5 5 33 FELIS 65 kW CIRCUIT AND FLUE CONNECTIONS ...

Страница 37: ...98 mm 130 mm 185 mm 290 mm 71 mm 93 mm 280 mm 405 mm 145 mm 236 mm 1 2 3 4 5 5 1 2 4 3 1 SIPHON 2 CH RETURN 1 3 4 CH FLOW 1 GAS 1 5 FLUE Ø100 150mm 34 FELIS 100 kW CIRCUIT AND FLUE CONNECTIONS ...

Страница 38: ...98 mm 130 mm 185 mm 365 mm 71 mm 93 mm 280 mm 405 mm 145 mm 236 mm 1 2 3 4 5 5 1 2 4 3 1 SIPHON 2 CH RETURN 1 3 4 CH FLOW 1 GAS 1 5 FLUE Ø100 150mm 35 FELIS 125 kW CIRCUIT AND FLUE CONNECTIONS ...

Страница 39: ...98 mm 210 mm 437 mm 71 mm 93 mm 270 mm 405 mm 145 mm 236 mm 1 2 3 4 5 5 1 2 4 3 1 SIPHON 2 CH RETURN 1 3 4 CH FLOW 1 GAS 1 5 FLUE Ø100 150mm 36 FELIS 150 kW CIRCUIT AND FLUE CONNECTIONS ...

Страница 40: ......

Страница 41: ...37 INFORMATION ABOUT REGULATIONS EU 811 2013 AND EU 813 2013 FELİS FL 50 65 100 125 150 HM Product Fiches and Package Label Calculations ...

Страница 42: ... for installation assembly and maintanence are described in the installation and service manual Specific precautions for assembly installation and maintanence Rated heat output Prated Annual energy consumption Space heating 51 Product fiche for combination boilers as required by EU regulations No 811 2013 Energy efficiency Sound Power Level Lwa indoors Space Heating Temperature application Efficie...

Страница 43: ...n this fiche may not correspond to its actual energy efficiency once installed in a building as this efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics II The factor for weighting the heat output of preferential and supplementary heaters of a package as set out in the followi...

Страница 44: ...Psup 1 2 II package without hot water storage tank II package with hot water storage tank 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 1 The intermediate values are calculated by linear interpolation between in two adjacent values 2 Prated is related to the preferential space heater or combination heater 0 6 0 98 1 0 7 1 1 40 ...

Страница 45: ...4 3 61000 4 4 61000 4 5 61000 4 6 61000 4 11 Aşağıda imzası bulunan şirketimiz yukarıda adı tipi ve modeli belirlenen cihazları ekte yer alan B 18 05 2708 EU numaralı rapor dahilinde ilgili standartlara AT Gaz Yakan Cihazlar ve AT Sıcak Su Kazanlarının Verimlilik Yönetmeliklerine uygun olarak tasarlayıp ürettiği beyan eder The undersigned company certifies under its sole responsibility that the it...

Страница 46: ......

Страница 47: ... Gas Fueled Boiler E C A Serial No Delivery Place and Date Maximum Repair Period 2 0 Work Days Warranty Period 3 Years AUTHORIZED SERVICE Installation Date Date Signature and Stamp Phone Fax FREE INITIAL OPERATION COUPON Type Brand Model Serial No Installation Date Authorized Service TIiie Date Service Voucher No Gas Fueled Boiler E C A ...

Страница 48: ...Sanayi Bölgesi 3 Kısım Mustafa Kemal Bulvarı No 13 45030 MANISA Mustafa Kemal Bulvarı No 13 45030 MANISA TURKEY Tel 90 236 213 00 21 Tel 90 236 213 00 21 Fax 90 236 213 08 59 Fax 90 236 213 08 59 email emas emas com tr www emas com tr email emas emas com tr www emas com t 7006721640 2 0 ...

Отзывы: