Mobile motorized height adjustable stand
Regout Balance Systems B.V. Industrieweg 40 6219NR Maastricht the Netherlands
Thomas Regout Inc. 121 Smokehill Lane Woodstock 30188 GA USA
11
DIMENSIONS
FAQ: Frequently Asked Questions
A: The e-Box® does not move up or down
A1: Check the power lead is connected to the wall outlet, if not connect the power lead.
A2: Check the cable connections to the control box Page 10 step 1 and 2, make sure the cables are connected.
A3: Check the connection of the short motor cable to the control box cable, make sure the cables are connected.
A4: Check for wiring damage from bad assembly: page 5 on step 4: If wiring is damaged, disconnect the e-Box® from
the wall outlet and contact your dealer for a replacement or repair.
WARNING: DO NOT ATTEMPT TO REPAIR BROKEN WIRING!
A5: The e-Box® motors are intended for intermittent use, continuous or extended use (more than 6 minutes) will
cause over-heating and a safety system will switch the motors off, if this happens allow the motors to cool down
for at least 1 hour. The system will automatically switch back to normal when the motors have cooled down.
A6: If steps A1 to A4 have been found in order and the problem still exists, contact your dealer for repair of the unit.
B: The motors don’t move smoothly or the left and right motors are at a different height
B1: Follow steps 3 to 6 on page 10 to synchronize the motors
C: The e-Box® only moves down and not up: the e-Box went into safe-mode, a power cut may have happened during
operation, or there is a bad wiring connection.
C1: Follow the steps 3 to 6 on page 10 to synchronize the motors
C2: If the problem still exists follow steps A1 to A4