E-Banking Tech EB-300 Скачать руководство пользователя страница 14

 

14 

5. Operating

 

Placing Bills onto the Hopper

 

It is very important to place the bills onto the hopper correctly because recognition performance of 

the bills is highly affected by the arrangement of the bills. Please avoid counting bills in bad 

condition such as wet, excessively dirty, spoiled, folded, curled notes and with foreign material like 

clips, bands, etc. Sometimes it causes malfunction of the machine. 

 

Counting 

If ADD mode was set, the cumulative number will be displayed. 

If an error occurs during operation and the machine stops, then an error message will be displayed. 

To clear the error, press RESET / START key. The machine will try to solve the problem 

automatically, but if it fails to clear a jam or there are some other mechanical errors, remove 

jammed bills manually. Then press the start/stop key again to clear error message.     

 
Selecting Add Function

 

 

ADD

 function provides a cumulative count, to the operator. For example, if someone tries to count 

up to 400, but the machine cannot count over 300, which is maximum capacity of the Stacker.   

But pressing 

ADD

 key, then try to count again. The machine counts and stops when the stacker is 

full.    After removing those notes from the Stacker, you can begin counting again, and the total 

counted number will be increased from the previous total. 

The Add function is On/Off by pressing ADD key and clears counted value by RESET / START key. 

 

Selecting Batch Function

 

BAT

 key is used to select preset batch number. In the batch count mode, the machine stops 

counting when the counted number reaches at the set number, even though the bills remain on the 

Hopper. User can edit batch number by pressing    0~9 number key. 

   

 

Selecting Automatic/Manual

 

In AUTOMACTIC mode, when the hopper sensor detect banknote on the hopper, machine will 

automatically start to count the bill.   

In MANUAL mode, the machine will not count the bills automatically even though the bills are onto 

the hopper. When user presses RESET / START key manually, the machine will start to count. 

While counting, the machine will display the number of the bills on FND display and it stops 

working when it meets the conditions described as below; 

No bills on the hopper 

The number of the bills counted is the same as the batch number to be set in BATCH mode. 

Errors have occurred. 

When the machine finishes counting without errors, the number of counted bills will be displayed on 

the screen.   

 

Содержание EB-300

Страница 1: ...1 EB 300 EB 310 Simple Counter with Detection Counting Detecting OPERATING MANUAL E Banking Tech Co Ltd...

Страница 2: ...hine unplug it from the power outlet Clean exposed parts with a soft cloth slightly dampened with water Do not use aerosol cleaners Gas Leaks Never use any machine close to a gas leak If you think gas...

Страница 3: ...achine This unit has many sophisticated sensors Without proper maintenance it cannot last its good performance Please read the Daily Maintenance section of this manual carefully and do it everyday Whe...

Страница 4: ...nel 7 12 Part 4 Overview of Display 13 Part 5 Operating 14 Placing Bills onto the Hopper Counting Selecting Add Function Selecting Batch Function Selecting Automatic manual Part 6 User setting menu 15...

Страница 5: ...ts NO The name of the Parts note 1 Guide for counting Note Expansion Guide 2 Hopper 3 Thickness Adjustment Screw Gap Control screw 4 Stacker 5 Handle 6 Connector for external display 7 Power Switch 8...

Страница 6: ...6 2 Classification of models Model Sensor IR UV MG Size 3D EB 300 O X X X EB 300UV O O X X EB 300MG O X O X EB 310 O O O X EB 310SU O O X O EB 310S O O O O...

Страница 7: ...0 EB 310S EB 310SU UV DETECTION ON OFF MG DETECTION ON OFF DIFFERENT DENOMINATION DETECTION ON OFF ACCUMULATED NUMBER COUNT PRESET NUMBER OF NOTES ONLY FOR SETTING MENU CLEAR THE COUNTED NUMBER or MAN...

Страница 8: ...reen 2 This key can be used to detect different denomination note by vertical size Specially 310S 310SU model detect by 3D size sensor 2 When press ADD key the accumulated total of notes will be shown...

Страница 9: ...r On the other condition RESET START key performs reset the machine or manual start on manual counting mode 2 By pressing 9 DOWN key you can input 9 or move to the next line in setting mode 2 By press...

Страница 10: ...OMINATION DETECTION ON OFF AUTO COUNTING MANUAL COUNTING COUNTING SPEED ACCUMULATED NUMBER COUNT PRESET NUMBER OF NOTES ONLY FOR SETTING MENU CLEAR THE COUNTED NUMBER or MANUAL START KEY DOWN OR NUMBE...

Страница 11: ...n change the counting speed under DEN off mode only 2 When press ADD key the accumulated total of notes will be shown on the screen when they have been counted By pressing CLEAR BACK key user can clea...

Страница 12: ...key performs reset the machine or manual start on manual counting mode 2 By pressing 9 DOWN key you can input 9 or move to the next line in setting mode 2 By pressing 0 UP key you can input 0 or move...

Страница 13: ...13 4 Overview of Display Counted number number of notes Max 4 digit BATCH function Display the batch number Max 3 digit Counting number Batch number...

Страница 14: ...The machine counts and stops when the stacker is full After removing those notes from the Stacker you can begin counting again and the total counted number will be increased from the previous total Th...

Страница 15: ...enu is not work on EB 300 2 Ed A Double level setting L A auto default L 1 level 1 L 2 level 2 L 3 level 3 OFF Use or to select level 3 Bt A Initial preset number setting 100 default Use to set The in...

Страница 16: ...seconds machine notify to user by beep sound until remove it 30 default Use or to select value 8 HP t Hopper warning time set If the banknote remained on the stacker over 10 seconds after the last cou...

Страница 17: ...n the stacker sensor while initial checking Check the stacker sensor or remove banknote E_EN Motor runs but no response of encoder Check the encoder sensor and cable connections E_PL Note passed with...

Страница 18: ...Counting Speed 1000 1200 1300 1500 1800 Min Preset Batch Number 1 999 Counterfeit Detection option MG MT UV FL IR Connectivity Serial RS232C Power Requirements 100 240VAC 50 60Hz 1 5A Notes This mach...

Страница 19: ...ate of purchased product Warranty exclusion A failure occurred by customer s negligence or incorrect operation A failure occurred by alternation of product or repair from non certified service enginee...