Dyzle BV, 2d Transistorstraat, 1322 CE Almere (NL), Tel.: +31(0)36-5233900, Fax: +31(0)36-5233999
© 2015 Dyzle User Manual for Y-Gate UMTS/GPRS 9-30V 3.0, version 1.3, March 2015
3
* For Interactive Voice Response (IVR): ask the support department about the possibilities.
General description of the Y-Gate UMTS/GPRS 9-30V 3.0
The Dyzle Y-Gate UMTS/GPRS 9-30V 3.0 is the base station for mobile locations without GPS. The
Y-Gate collects measurement data from the Y-Tags and sends the data to the Dyzle server through
the UMTS/GPRS network (mobile internet). The Y-Gate does not store any data. The Y-Tags are the
measuring sensors. The Y-Tags take a measurement every five minutes and send the measurement
data to the Y-Gate. The nature of the data depends on the type of the Y-Tag, for example temperature
data or humidity data.
Product specifications
*
Product code
010 1701 003
Memory
None
Connectivity to Y-Gate
WIFID, 2.4 GHz (coded)
Connectivity range
100 m (unobstructed)
Maximum number of connected
sensors
64
Power supply
9 - 30V DC
Operating temperature
-25 °C to +50 °C
Water resistance
IP30
Accessories supplied
UMTS/GPRS antenna, WIFID antenna (2.4 GHz), power cable
* Refer to the separate product specifications overview for the comprehensive product features.
Safety
Installation of a Y-Gate requires general knowledge of safe work practices, therefore may only be
carried out by personnel holding the required operational Safety Certificate, and should also have the
necessary knowledge of the spaces, equipment and vehicles that will be measured for temperature as
well as the location where the system is to be installed.
Placement and installation
Confirm that the Y-Gate is complete before proceeding to install it: base station, UMTS/GPRS
antenna, WIFID antenna and power cable, and consult the Dyzle Hardware Installation Manual.
During the installation bear the following in mind:
•
Connecting the Y-Gate’s power supply at a mobile location is different from connecting the
power supply at a stationary location.
•
Do not install the Y-Gate in a damp or wet environment, or in the freezer section.
•
One should preferably use the vehicle’s battery as power source for the Y-Gate on mobile
location. Note: always use the appropriate power cord: red is +, green (optional) is +, and
black is the ground. Always install a 5 amp inline fuse on the + wire.
Maintenance and problems
The exterior of the Y-Gate can be cleaned using a soft, damp cloth. Do not use any detergents.
Additional maintenance may only be carried out by personnel holding a operational Safety Certificate.
Consult Part 4 of the Dyzle Hardware Installation Manual for more information. For questions contact
your supplier.
Warranty
Refer to Dyzle’s General Terms and Conditions of Sale and Delivery for our warranty terms. Contact
your supplier before returning the item in case of a warranty claim.