2-23
D Y N O I N S T A L L A T I O N
Eddy Current Brake Installation
Version 4
Above Ground Model 250i Motorcycle Dynamometer Installation Guide
I
NSTALLING
THE
L
OAD
C
ELL
The load cell is an optional accessory. This section describes how to remove the
existing bar on the eddy current brake and install the load cell. If you did not purchase
the load cell, skip this section and continue with “Secure the Dyno and Brake Module
to the Floor” on page 2-25.
You will need the following part:
1
Verify the main dyno power is disconnected. Refer to“Main Dyno Power” on page
3-2 for more information.
2
Remove the two bolts and nuts securing the existing bar on the eddy current brake
and remove the bar. Set the bolts and nuts aside.
Figure 2-20: Remove the Existing Bar
part
description
load cell and cable
P/N 76950573
bar