background image

1

User Manual

PowerDepot H5B

Содержание PowerDepot H5B

Страница 1: ...1 User Manual PowerDepot H5B ...

Страница 2: ...and Weight 3 2 2 Performance Parameter 3 2 3 Interface Definition 3 2 4 Battery Management System BMS 5 2 4 1 Voltage Protection 5 2 4 2 Current Protection 6 2 4 3 Temperature Protection 6 2 4 4 Other Protection 6 3 Installation and Configuration 7 3 1 Preparations for installation 7 3 1 1 Environmental requirements 7 3 1 2 Tools and data 8 3 1 3 Technical preparation 8 3 1 4 Unpacking inspection ...

Страница 3: ...ngs on the inverter 22 3 2 6 Register on the website after installation 22 4 Use maintenance and troubleshooting 24 4 1 Battery system usage and operation instructions 24 4 2 Alarm description and processing 25 4 2 1 Alarm and countermeasure for affecting system output 25 4 2 2 Alarm and countermeasure for un affecting system output 25 4 3 Analysis and treatment of common faults 25 ...

Страница 4: ...design requirements of environmental protection and personal safety The storage use and disposal of the products shall be carried out in accordance with the product manual relevant contract or relevant laws and regulations Customer can check the related information on the website of Daqin New Energy Tech Taizhou Co Ltd when the product or technology is updated Web URL http www dyness tech com cn P...

Страница 5: ...efore use in order to ensure your safety To assure the proper use please make sure parameters among the relevant device are compatible and matched Please do not mixed use batteries from different manufacturers different types and models as well as old and new together Ambient and storage method could impact the product life span please comply with the operation environment instruction to ensure de...

Страница 6: ...on maintenance Safety Statement Only qualified and trained professionals are qualified to install operate maintain the device Please comply with local safety regulations and operational rules during installation operation and maintenance or it could cause unexpected injury or device damage The safety declaration mentioned in the manual are only supplement context for your local safety regulations ...

Страница 7: ...gy storage product s anode materials are lithium iron phosphate battery cells are managed effectively by BMS with better performance The systems features as below Comply with European ROHS Certified SGS employ non toxic non pollution environment friendly battery Anode materials are lithium iron phosphate LiFePO4 high safety performance longer life span Equipped with BMS battery management system m...

Страница 8: ...ns and be aware of the dangers Read the user manual before using The scrapped battery cannot be put into the garbage can and must be professionally recycled After the battery life is terminated the battery can continue to be used after it recycled by the professional recycling organization and do not discard it at will This battery product meets European directive requirements This battery product...

Страница 9: ...2 2 Performance Parameter Table 2 2 PowerDepot H5B performance parameter Item PowerDepot H5B Nominal Voltage V 51 2 Work Voltage Range V 44 8 57 6 Nominal Capacity Ah 100Ah Nominal Energy kWh 5 12 Nominal Power kW 2 56 Max Charging Discharge Current A 90 100 Charging Current A 50 Discharge Current A 50 2 3 Interface Definition This section elaborates on interface functions of the front panel of th...

Страница 10: ...nnected to the COM OUT interface of the previous PowerDepot H5B through communication cable Factory default CAN communication mode 3 Negative socket The battery DC output negative pole which is connected to the negative pole of the inverter through the cable 4 COM OUT When the system is used independently This CAN RS485 socket is a reservation interface When the system is used in parallel This CAN...

Страница 11: ...protection 10 COM Communication cascade port support RS232 Table2 4 SOC ALM Light instructions Battery State SOC LED1 LED2 LED3 ALM Shut down off off off off Standby 66 SOC 100 On On On On 33 SOC 66 On On Off On 20 SOC 33 On Off off On 10 SOC 20 On off off On 0 SOC 10 On off off On 2 4 Battery Management System BMS 2 4 1 Voltage Protection Low Voltage Protection in Discharging When any battery cel...

Страница 12: ...emperature protection be activated device stops charging The protection is released when it back to rated range of working temperature Low Over temperature protection in discharging When battery s temperature is beyond range of 20 55 during discharging temperature protection be activated device stops supplying power to the outside The protection is released when it back to rated range of working t...

Страница 13: ...tective measures to avoid touching these cables while operating power equipment when installing the battery system must wear the protective items below The isolation gloves Safety goggles Safety shoes 3 1 1 Environmental requirements Working temperature 20o C 55 o C Charging temperature range is 0o C 55 o C Discharging temperature range is 20 o C 55 o C Storage temperature 10o C 35 o C Relative hu...

Страница 14: ... supply equipment The DC standby interface and the maximum discharge current shall be higher than the maximum charging current of the products used in table 2 2 If DC interface maximum discharge capacity of the user s equipment is less than the maximum charging current of products using in table 2 2 the user s interface should have the power equipment of DC current limiting function to ensuring th...

Страница 15: ...ng list ensure objects are complete and intact If the internal packaging is damaged it must be inspected and recorded in detail Packing list is as follows Battery 1 Battery bottom bracket 1 Support bracket 2 M6 bolt 8 Fixing battery box with battery bracket Power cable 2 connect battery with DC breaker Standard Communication cable 1 User manual 1 Positioning cardboard 2 Expansion screw 8 120ΩCAN r...

Страница 16: ...ire are reasonable Not easy to short circuit water and corrosion 3 2 Equipment installation The wall for battery installation shall be solid brick or cement wall with strong bearing capacity and wall thickness no less than 100mm Mounting space requirements Floor installation Wall installation If the battery is installed indoors please leave a certain gap during installation according to the pictur...

Страница 17: ... ground a fixed support must be used to fix the top of the battery box on the wall 1 Use the positioning cardboard provided in accessory package and mark the screw hole positions on the wall as shown four holes in the picture on the left 2 The bottom of the board must be in horizontal touch with the ground while marking the holes 3 According to the marked position use an electric drill to drill 4 ...

Страница 18: ...ll Battery bottom bracket 1 Expansion screw 4 4 Fixing the expansion bolt M6 into the bottom of the hole on the wall 5 Use the M6 bolt to fixing the Support bracket to the wall and control the torque at 6NM 6 Carry the battery box to the installation site and place it about 15mm away from the wall surface fixing the Support bracket and the ...

Страница 19: ...und while marking the holes 3 The bottom of the cardboard is about 300mm to the ground 5 Fixing the shell of the M6 expansion bolt into the hole on the wall and fix the Support bracket and Battery bottom bracket on the wall with M6 bolts and control the torque force 6NM 4 According to the marked position use an electric drill to drill 8 holes with a diameter of 10mm on the wall for installing M6 e...

Страница 20: ...alls it means the cable is in good condition After visual testing of power line connection the positive and negative poles of the battery shall be connected respectively to the positive and negative poles of another device inverter Connect the battery box to the ground cable Customer needs to prepare a M6 OT terminals and ground cables Connect the battery shell as shown below The sectional area of...

Страница 21: ... ID of the PowerDepot H5B We will record the battery ID and give device opening operation authorization Except changing the DIP switch mode no other operations can be done The connection between inverter and battery should apply the power cable and communication cable which has been offered in your accessory package the communication cable is standardized type and The applicable inverter module ha...

Страница 22: ... RS485 communication interface of the inverter by a RJ45 communication cable Table 3 3 Pin Definition Foot position Color Definition PIN1 Orange white 485B PIN2 Orange 485A PIN3 Green white XGND PIN4 Blue CANH PIN5 Blue white CANL PIN6 Green Reserved PIN7 Brown white XIN PIN8 Brown Reserved ...

Страница 23: ... According to the number of parallel system Take three PowerDepot H5B in parallel as an example the system needs to use Power cable 3pair Battery Inverter communication cable 1PCS Battery Battery communication cable 2PCS Distribution box 1PCS The over current capacity of the distribution box should be much higher than the maximum nominal current value when the load is running PINOUT of system para...

Страница 24: ...lection 1 2 3 4 Define different protocols Distinguish between master and slave Baud rate selection OFF CAN 500K 485 9600 ON CAN 250K 485 115200 DIP switch description When the batteries are connected in parallel the host communicates with the slaves through the CAN interface The host summarizes the information of the entire battery system and communicates with the inverter through CAN or 485 ...

Страница 25: ...attery you need put the master DIP switch 3 to the ON position to the top then turn on the batteries 3 If the battery communicate with the Axpert king VMIII MAX Growatt SPH CAN comm GMDE change the master module DIP switch to 0100 2 to ON before connecting 4 If the battery communicates with the Growatt SPF HVM P ES WPV by RS485 communication change the master module DIP switch to 0110 2 3 to ON be...

Страница 26: ...rgy storage system has only one powerdepot it is the master itself and still follow the above steps Note For more information of matching inverter brands please subject to the latest document The list of compatibility between Dyness ESS and Inverters Caution Proceed as follows a Remove the four screws on the cover and open the cover b Find the red DIP switch on the module and confirm the status of...

Страница 27: ...onfirm the charge and discharge parameters of the inverter interface Voltage and current should meet the requirements of Table 2 2 battery performance parameters When you use battery in parallel it doesn t need to change the DIP switch of the host module in the master PowerDepot H5B which communicates with the inverter directly How to judge that the communication between PowerDepot H5B and PowerDe...

Страница 28: ...ttery s long term continuous charging current should be 0 5C b If the battery remaining capacity is empty please charge it within 48 hours after the battery is empty Discharging c The long term continuous discharge current of the battery should be 0 5C d The recommend maximum depth of discharge DOD of Battery PACK is no more than 85 3 2 5 Battery parameter settings on the inverter Max Charging Bul...

Страница 29: ...ot H5B series User Manual 23 product installation and use information to make the product warranty effective Please follow the instructions on the website to register http www dyness tech com cn Service Sign Up ...

Страница 30: ...e battery has begun to work normally 4 After confirm the battery output voltage and polarity are correct turn on the inverter then turn on the circuit breaker switch 5 Check whether the indicator light for the inverter and the battery connection the communication indicator and the battery access status indicator is in normal condition If normal the connection between the battery and the inverter i...

Страница 31: ...f the trouble Low voltage alarm RED light flashing Buzzer start Start charging SOC less than 10 LED1 RED light on Start charging 4 2 2 Alarm and countermeasure for un affecting system output If a low SOC alarm occurs the battery system also issues a corresponding alarm signal Maintainer should check the equipment according to the prompt information determine the type and position of the fault and ...

Страница 32: ...7V 57 6V range 5 The power cable sparks when system power on and ALM indicated Red light on Power connection short circuit Turn off the battery check the cause of the short circuit 6 ALM LED flash alternately without stopping Modules communication address distribution is faulty Check the external communication cable connection firstly Check the slave PowerDepot H5B DIP setting If you have any tech...

Страница 33: ...rgy Tech Taizhou Co Ltd Address Building 13 Kunshan Jiangyan Industrial Park Chenzhuang West Road Jiangyan District Taizhou City Jiangsu Province China 225500 Email sales dyness tech com Website www dyness tech com ...

Отзывы: