Dynasound DS1042 Скачать руководство пользователя страница 4

Dynasound, Inc. 6439 Atlantic Blvd. Norcross, GA. 30071      800.989.6275

 

LOUDNESS LEVEL

. The system can now be subjectively fine tuned for effectiveness and comfort. If 

the sound masking level is too high, turn the volume control knob counterclockwise, in no more than 

fifteen minute increments, until the desired loudness level is achieved. If the sound masking level is too 

low, turn the volume control knob clockwise, in fifteen minute increments, until the desired loudness 

level is achieved.

Equalization

IF ASSISTANCE IS REQUIRED: CALL (800) 989-6275.

If a sound level meter is available, the following spectrums are recommended:

FREQUENCY 100  125  160  200  250  315  400  500  630  800  1000  1250

1/3 OCTAVE    47   46 

45 

44 

43 

42 

41 

40 

39 

37 

35 

34

ONE OCTAVE  

51  

 

 

48  

 

 

45  

 

 

40

FREQUENCY 1600  2000  2500  3150  4000  5000  6300  8000  1000

1/3 OCTAVE   32 

30 

27 

24 

21 

20 

17 

14 

11

ONE OCTAVE  

35  

 

 

26  

 

 

19

control indicator at the 8:30 position on the dial and the equalizer control to the 11:30 position. If these 

design characteristics do not apply, ontact Dynasound, (800) 989-6275,for tuning assistance.

OCCUPIED SPACES

If masking sound is being added to an existing space that is currently in use, THE MASKING MUST BE 

INTRODUCED SLOWLY, so that it won’t call attention to itself. Therefore, once the initial installation is 

complete, it will take weeks to bring the masking sound up to its recommended level for effective pri-

vacy.  After tuning the masking as per the above procedure for unoccupied new space, record the final 

settings for both the volume and equalizer controls. Indicate on the bottom of the DS1042 unit, with a 

permanent marker, the recommended settings.

INITIAL MASKING LEVEL SETTINGS FOR OCCUPIED SPACES 

If you have a sound level meter, measure the existing ambient background in several areas and record 

the lowest reading. Now go to the DS1042 unit and set the volume so that the masking level is 2 dBA 

above the lowest ambient reading that was recorded. If you do not have a sound level meter, set the vol-

ume control on the DS1042 unit to eight (8) o’clock.

RAISING THE INITIAL MASKING LEVEL SETTINGS IN OCCUPIED SPACES

After a continuous Monday to Friday cycle of non-interrupted masking at the initial setting, raise the 

masking level 2 dBA or about fifteen (15) minutes on the volume control from the initial setting. This 

increase in level must be done on Friday at the end of the work day after most of the employees have 

left the building.

Continue this weekly increase until the final setting as determined above is met. If there are ob

jections 

Отзывы: