![Dynaset HPW-DUST Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/dynaset/hpw-dust/hpw-dust_operating-instructions-manual_2548776007.webp)
7
A HYDRAULIC ACTUATOR VALVE KIT
HYDRAULIC VALVE KIT
for a
DUAL WATER CIRCUIT
SYSTEM
(DWC)
includes following components:
PRESSURE REDUCING VALVE
2.2
, FLOW LIMITING VALVE
2.3
and SOLENOID VALVE
2.4
.
In
OC-hydraulic systems
, HPW-pump is operated under constant hydraulic pressure. The output water flow and
eventually hydraulic flow is rated by the size of installed water nozzles.
The flow limiting valve is adjusted at factory to the throughput required by high power dust suppression.
Valve kit for
Open centre hydraulic
systems
includes pressure compensator
PV-SAE
pos.
2.1
. When installing
to close centre hydraulic system, concerned pressure compensator is not required.
2.2
Pressure reducer
7-210
Flow limiter R3/4 u s
Solenoid valve
2/2 NC
PC-SAE 3/4"
OC-HYDRAULICS
2.3
2.4
2.2
2.1
A
B
T
P
LS
P
LS
2.3
1
3
2
2.4
2.3
Control valve kit for single water circuit system (
SWC
).
Flow limiting
valve
On / Off -valve
Solenoid-valve
HYDRAULIC VALVE KIT
for
SINGLE WATER CIRCUIT
(
SWC
) SYSTEM provides two separate hydraulic flows,
one for both power level of dust suppression.
Pressure relief valve
HPW200 dust double-DWC, D200105350
April 2014 JLe
HPW-DUST HIGH PRESSURE SUPPRESSION SYSTEMS
P