DI651ST2  User  Manual    19 

 

 

 

ITEM 1 

ITEM 2 

DEFAULT

 

DESCRIPTION

 

Advance 

Display Mode 

Auto 

Change the Menu orientation.    The Menu 
can be displayed in either LANDSCAPE or 
PORTRAIT mode.

 

Screen 
Protection 

Off 

Turn on / off image burn-in protection. 
Set image burn-in protection interval. 
Range 1 

– 100. 

IR Control 

On 

Enable/disable the remote control for Menu. 

Note

: When disabled, the remote control 

function can be enabled again from the 
control panel on the display or through the 
DynaScan “Display Manager” application. 

Power Off Mode 

Standby 

When in Power Off Mode, RS-232 controls 
do not function.    Only [Main Power Switch] 
on the display or [Power Button] on the 
remote control can wake up the display. 

Volume 

100 

Set volume. 
Range 100 

– 0. 

Reset to Default 
Setting 

Off 

Restore all settings to default. 

Note

: It does not modify CURRENT TIME, 

POWER ON TIME and POWER OFF TIME. 

 
 

 

 

ITEM 1 

ITEM 2 

DEFAULT

 

DESCRIPTION

 

Information 1 

Resolution 

 

Input resolution. 

Model 

DI651ST2 

The display’s model. 

Serial Number 

 

The display’s serial number. 

Hardware 

 

The H/W version. 

Firmware 

 

The F/W version. 

Color Depth 

 

The color depth of current input. 

 
 
 
 

Содержание DI651ST2

Страница 1: ...ual DI651ST2 Version 2 02 The use of diagrams and illustrations in the manual are for reference only The actual product may be different Product design and specifications are subject to change without...

Страница 2: ...Batteries 6 Installation 7 Mounting 7 Wall Mounting 10 Connecting to a Power Source 10 Connecting an External Video Source 11 Input Output Terminals 12 Operating Instructions 13 Powering On Off the Di...

Страница 3: ...can is firmly committed to its environmental protection efforts and we believe that reducing our products impact on the environment is of the utmost importance We are dedicated to meet the latest envi...

Страница 4: ...ng measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the rec...

Страница 5: ...nplug the display and contact the dealer Clean only with soft dry cloth but not use chemical liquids and unplug while cleaning Do not use extreme force or any sharp or pointed objects to touch the dis...

Страница 6: ...nd other particles Unplug the LCD immediately and contact a DynaScan certified service professional as soon as possible when any of the following situations occurs Damaged power cord or power plug If...

Страница 7: ...ada EU Except U K Japan Taiwan Voltage 120V 230V 100V 110V NEMA TYPE NEMA 5 15 CEE 7 7 NEMA 1 15 NEMA 5 15 IEC Display Plug IEC Plug TYPE IEC320 C13 Installing and Replacing Remote Control Batteries 1...

Страница 8: ...l disasters DynaScan recommends having certified professionals to evaluate the installation site and perform the mounting operation Do not to cover the vent and or the heat sink in order to ensure pro...

Страница 9: ...trength to support the LCD and its accessories Do not install in a location with strong vibrations or is dusty Do not install near the building s main electric panel Ensure the LCD is secured in such...

Страница 10: ...secured to the building s structural frame such as a beam rather than light steel frame or interior decoration Do not use wood screws or dry wall anchors for installation Maintenance Inspect the fast...

Страница 11: ...n 15 degrees of the vertical axis Do not install the wall mount while the power is turned on as it may cause serious injury from electrical shock Connecting to a Power Source Using the power cable pro...

Страница 12: ...cable or DP cable HDMI cable provided insert one end into the DVI IN or DP IN HDMI IN on the back of the display shown the in the diagram below Connect the other end of the DVI cable or DP cable HDMI...

Страница 13: ...t of a PC or the HDMI output of an AV device via a DVI HDMI cable 8 HDMI IN Connect the HDMI output of a PC or the HDMI output of an AV device via a HDMI cable 9 DP IN Connect the DP output of a PC or...

Страница 14: ...the IR receiver on the display The IR receiver on the DI551ST2 model is at the rear of the display with a receiving angle of 100 degrees The IR receiver configurations of the model are shown in the fi...

Страница 15: ...DI651ST2 User Manual 14 DI651ST2...

Страница 16: ...On Off MENU OSD On Off UP Move the cursor up or change the setting of selected item LEFT Exit the current selection RIGHT Select the highlighted item DOWN Move the cursor down or change the setting o...

Страница 17: ...ontrols ITEM DESCRIPTION MENU OSD On Off Power On Off UP Move the cursor up or change the setting of selected item DOWN Move the cursor down or change the setting of selected item LEFT Exit the curren...

Страница 18: ...SCRIPTION Picture Color Temperature D65 Select the color temperature User D93 D65 and D95 R Adjust the red light level Range 0 100 Note The feature is only supported on User mode G Adjust the green li...

Страница 19: ...at HIGH LEVEL brightness value If the AUTO BRIGHTNESS is on Auto the display brightness adjusts according to the ambient light When ambient light is bright the screen will adjust to the HIGH LEVEL br...

Страница 20: ...y or through the DynaScan Display Manager application Power Off Mode Standby When in Power Off Mode RS 232 controls do not function Only Main Power Switch on the display or Power Button on the remote...

Страница 21: ...2 DEFAULT DESCRIPTION Information 3 Over Heat Protection Inactive It will enter into protection mode when the display internal temperature is over heat 56 C Brightness 50 61 C Brightness 25 66 C Brigh...

Страница 22: ...by Mode 1W MECHANICAL SPECS Bezel Width T B L R 22 0 22 0 12 9 12 9 mm Cabinet Color Black Monitor Dimension LxHxD w o Stand 1457 x 851 x 60 mm Monitor Weight set package 39 5 kg 45 kg VESA Mounting D...

Страница 23: ...Pixel Rate Aspect Ratio H Pixels V Lines 640 480 60 Hz 25 175 MHz 4 3 720 480 59 94 Hz 27 MHz 4 3 800 600 60 Hz 40 MHz 4 3 1024 768 60 Hz 65 MHz 4 3 1280 720 60 Hz 74 25 MHz 16 9 1280 768 60 Hz 79 5 M...

Страница 24: ...ield RX2 RX4 11 Shield RX1 RX3 19 Shield RX0 RX5 04 NC 12 NC 20 NC 05 NC 13 NC 21 NC 06 DDC Serial Clock 14 5V power 22 Shield RXC 07 DDC Serial Data 15 Ground 23 RXC 08 NC 16 Hot plug detect 24 RXC R...

Страница 25: ...ge is unstable Check whether the cable is completely plugged in The remote control does not work Check whether there are batteries in the remote control Check the batteries for freshness polarity etc...

Страница 26: ...USB flash drive storage SD card or Internet How to Switch to DSM365 Press the MENU button on either the rear panel control or remote control to show the OSD Use the navigation arrows to select and ad...

Страница 27: ...DI651ST2 User Manual 26 www dynascandisplay com Copyright DynaScan Technology Inc All Rights Reserved...

Отзывы: