STORAGE

1. Switch off power from main and unplug, 

separate the pump from the mattress and 

place the mattress flat.

2. Fold the mattress in two from mattress foot 

to head.

3. Allow time for air to escape from mattress to 

reduce storage space.

4. Close the protective cap cover on the quick 

connector.

GENERAL CONDITIONS OF DISPOSAL

Dispose of the device in the appropriate 

disposal areas for recycling. At the end of its 

life, the product must not be disposed of along 

with other domestic waste.

MAINTENANCE

In case of repair, use only original spare parts 

and accessories. For spare parts and 

accessories, please contact Dynarex or an 

authorized dealer.

CLEANING AND DISINFECTION

WARNING! Unplug the pump before 

starting the cleaning procedure.

1. Clean the mattress with mild soap.
2. Do not immerse or soak pump unit.
3. After cleaning, dry the mattress without 

direct sunlight exposure.

4. Check that the connection tubes are not 

obstructed by dust or other objects. Use a 

soft swab to clean the tubes if necessary.

NOTE:

 Never use acids, alkalis or solvents 

such as acetone to clean the mattress.

No lights on unit

Low pressure alert

Patient’s body is sagging

in the middle/bottoming out

Control lock up or “freeze” 

Check control unit is connect to the main power supply and that 

the unit is switched on.
Check quick blow fuse on the control unit or main plug fuse.

Check main power to the control unit and that the plug is switched.
Check mattress air supply connector is connected to the pump unit

correctly.
Check CPR connector is connected properly.
Under the mattress cover check all “T” & “L” connectors are 

connected to the air tubes.
Check the connector tubes for kinks, crimps or damage.

Increase the value of the comfort the setting. Wait a couple of 

minutes so pressure can stabilize before making another change.

Turn the control unit off and unplug the pump. Wait a few minutes 

and plug the control unit back in. Turn on the control unit.

TROUBLESHOOTING

If your questions can’t be answered with below information, please contact your

local agent directly. They might require a technician to take care of the problem.

PUMP

10441 & 10448 MATTRESS

10449 MATTRESS

1

5

3

4

2

6

1 - Pillow function cells
2 - Cover
3 - Fixing belt
4 - Low air loss holes
5 - Male quick connector
6 - Air tubing
7 - CPR Valve

1 - Power switch
2 - Presssure adjust knob
3 - Normal pressure indicator (green)
4 - Low pressure indicator (amber)
5 - Static control
6 - Air pressure valve

(1) Pillow

(2) Cover

(3) Fixing belt

(4) Low air loss holes

(5) Male quick connector

(6) Protective cap of connector

(7) Air tubing

(8) CPR valve

(9) Foam Base