1.2  ELECTRICAL INSTALLATION

IT IS VERY IMPORTANT

 that the mating connector 

and the encoder body be isolated from electrical 
ground in the wiring and conduit to prevent motor or 
machine shaft eddy currents from going to ground 
through the encoder bearings, as this will damage the 
bearings over time. To insure that this is being done, 
it is suggested that a plastic wiring/conduit  adaptor or 
non-conductive conduit is used to isolate the connector 
from any metallic surface or conductive conduit. Please 
see special note under table 1, for proper encoder 
connector shielding. Also, to allow for proper encoder 
grounding, the motor must be wired and grounded per 
your local NEC Requirements.

Electrical connections are made to the sensor 
module through a standard 1/2 inch NPT liquid tight 
flexible conduit. The nipple length may be changed 
to extend the outlet box if desired. Interconnection 
cable recommendations are as follows: stranded 
copper, 22 through 16 gage, braided or foil with drain 
wire shielding 0.05 F maximum total mutual or direct 
capacitance, outer sheath insulated. Shrink tubing may 
be placed over any wires without insulation. For lengths 
over 100 feet, use 18 gage or larger, to a maximum 
of 1000 feet. If shielded twisted pair wire is used, do 
not cross channels. Keep each pair of complementary 
channel outputs together in a single twisted pair (e.g., 
A and A). 

IMPORTANT: Reversing power and common will 
not damage the unit.  However, applying power to 
any of the sensor outputs may cause damage.

Grounding:

 For applications with high ground 

potential differences, DO NOT ground the encoder 
through both machine and controls end. Connect 
the shield at the controls end only. 

NOTE: If the 

shield is connected at both ends, grounding 
problems that degrade system performance can 
result.

 

CE Grounding Measures 

– For best EMC 

immunity the cable screen must be grounded on 
both encoder and controls end. For cable lengths 
longer than 30m or outdoor applications, additional 
measures must be implemented to comply with 
CE requirements. Connection of the encoder 
to DC power supply network is prohibited if CE 
compliance is required. CE-compliant products are 
tested to EN61326-1 EMC.

In all cases, system CE compliance is ultimately the 
responsibility of the manufacturer integrating the 
encoder.

NOTE: The shield in the sensor module is 
isolated from the frame of the encoder for 
maximum noise immunity. The shield wire or 
pin should be connected to the shield of the 
cable and that of the drive or other receiving 
device.

1.3  QUICK RELEASE CONNECTOR HOOD WIRING

To install the Quick Release Connector, perform the 
following steps.
1.Remove the four screws from the mating connector 
housing that hold the terminal block in place. Re-
move terminal block from housing.
2.Insert wiring through liquid tight flexible seal and 
mating connector housing. Leave enough wire ex-
posed to comfortably reach the terminal block. Wire 
to terminal block according to wire code in Table 1.  
A similar wiring list is attached to enclosure. 
3.Tighten Liquid Tight fitting on housing. OPTIONAL: 
In some hostile environments, seal between con-
nector body and Sensor Module can be improved 
by smearing a sealant (silicone grease, etc.) on the 
neoprene seal of the connector.

4. Mate connector into place on sensor mount and 
snap the two latches into place. If only one sensor is 
being installed, ensure cover plate is installed over 
other sensor hole.

Table 1. Signal Coding Table

* Index (Z) optional.  See Ordering Information 

† Alarm not available with Pigtail cable. See Ordering Information

Common
B
A
Z*
Alarm †
Vcc (5-26 VDC)
B
A
Z*
Shield

1
2
3
4
5
6
7
8
9
10

Black
Green
Blue
Violet
N/A
Red
Yellow
Gray
Orange
Braid

Signal                     Connector Pin     Pigtail Cable   MS 3102E18-IT# 

A
E
D
C
F
B
H
G
I
J

_
_
_

Содержание NorthStar NexGen RIM Tach HT85

Страница 1: ...Pulses per Revolution 60 2400 PPR Phasing Sense A leads B for Counter Clockwise rotation CCW viewing encoder mounted end Quadrature Phasing 90 45 Symmetry 50 15 Number of Output Modules Single or Dual ELECTRICAL Input Power Requirements 5 26VDC 95mA typical per sensor module plus line driver load Output Signals IC WE Differential Line Driver 150mA sink or source Frequency Response 0 180kHz Data In...

Страница 2: ...ollowing general guide lines will help to ensure a trouble free installation Mounting the Encoder Wiring the Encoder Never connect or disconnect the encoder con nector or wiring while power is ON Doing so may damage the encoder Power should always be connected to the side of DC power Common should always be connected to the side of DC power Never connect A B or Z to the or side of DC power In some...

Страница 3: ...them to the receiving device Any unused encoder signal wires must be individually insulated and tied back They should NEVER be in contact with common power sources or other output signal lines The encoder is correctly connected to the receiving device per the Electrical Specifications table and the receiving device s terminal strip label however it s counting in the wrong direction What s wrong In...

Страница 4: ...1 Encoder Housing Orientation 4 Tighten the clamping ring segment as follows see Figure 2 1 Look inside the access plate hole and rotate the hollow shaft until the two M5 0 8x12 mounting screw heads on clamping ring are visible 2 Being very careful not to damage the magnetic pulse wheel see Figure 2 below tighten down both mounting screws using the M4 T Handle hex wrench included Torque each mount...

Страница 5: ...he motor shaft during mounting A parallel orientation between the anti rotation arm and motor shaft is not recommended because it will significantly reduce the anti rotation arm s performance and operational lifetime Each rod end can withstand only 50 of deviation Ideally the anti rotation arm should be mounted with rod end ball centered in its socket Recommended torque 20 ft lbs 27 N m 1 1 SENSOR...

Страница 6: ...formance can result CE Grounding Measures For best EMC immunity the cable screen must be grounded on both encoder and controls end For cable lengths longer than 30m or outdoor applications additional measures must be implemented to comply with CE requirements Connection of the encoder to DC power supply network is prohibited if CE compliance is required CE compliant products are tested to EN61326 ...

Страница 7: ... 92 404 37 12 31 312 67 0 87 22 1 2 13 54 1 0 1 2 5 2 81 71 4 8 71 221 23 DIMENSIONS inch mm Ordering Information To order complete the model number with code numbers from the table below European Sales Representitive Hengstler GmbH Germany Uhlandstrasse 49 78554 Aldingen www hengstler com INNOVATION CUSTOMIZATION DELIVERY Customer Service Tel 1 800 873 8731 Fax 1 847 662 4150 custserv dynapar com...

Отзывы: