RC907/908-EV35 User Guide 

 

 
 

Chapter 1. Introduction

 

 

 

 

1.1 Product Introduction

 

 
 

RC907/908-EV35  series  interface  converter,  or  media  converter,  is  designed  to 
transmit  Ethernet  data  over  V.35  network.  Since  more  and  more  V.35  network 
resources  are  being  deployed,  various  types  of  data  transmission  solutions  that 
make use of V.35 links will be widely accepted by end-users. 

 

 

RC907-EV35 series interface converters are standalone interface converters. Every 
unit of device has an independence built-in power supply, and can be placed on the 
table. 

 

 

RC908-EV35 series interface converters are slide-in modular interface converters. 
They  can  be  installed  into  RC  series  16-slot  chassis  (19”  3U  high chassis),  
or  4-slot  chassis  (19”  1U  high  chassis),  or  single  slot  chassis.  When installed 
into 16-slot or 4-slot chassis, it can be mixed with other series products (e.g. 
copper-to-fiber media converters, single-port optical multiplexers) to enable  
uniform  network  management.  RC907-EV35  interface  converters  can  be 
deployed at the remote site to work in pairs with RC908-EV35. 

 

 

RC907/908-EV35 (Rev. B) has interoperability with the previous version (Rev. A). 
The differences between the two versions are only at Ethernet interfaces. So it is 
not necessary to consider other properties when they interconnect with each other. 
The bandwidth setup and clock phase configuration of Rev. B are the same as those 
of Rev. A. Please consult our technical support if encountering any problem. 

 

Содержание RC 907 EV 35

Страница 1: ...R RC C 9 90 07 7 E EV V 3 35 5 R RC C 9 90 08 8 E EV V 3 35 5 Ethernet to V 35 Interface Converter User Guide...

Страница 2: ...The Indicators on the Front Panel 4 1 3 2 The Definitions of Indicators 4 CHAPTER 2 CONNECTION CONFIGURATION 6 2 1 INTERFACE CONVERTER INTERCONNECTION 6 2 2 TYPICAL APPLICATIONS 6 2 3 DUPLEX MODE CONF...

Страница 3: ...can be installed into RC series 16 slot chassis 19 3U high chassis or 4 slot chassis 19 1U high chassis or single slot chassis When installed into 16 slot or 4 slot chassis it can be mixed with other...

Страница 4: ...Ethernet data frame up to 1595 bytes 4 Supports IEEE 802 3x flow control in full duplex mode 5 Supports back pressure flow control in half duplex mode 6 Built in 1k MAC address table with address fil...

Страница 5: ...rnet Link ETH Data TX RX Action LNK ACT DTE PWR UTP FDX Power Supply Full Duplex Figure 2 The front panel of RC908 EV35 1 3 2 The Definitions of Indicators Ethernet Link LNK On Ethernet link is proper...

Страница 6: ...The DTE connector HDB26 female connector Please refer to Chapter 3 for details of the interface definition and cable connection Ethernet interface The UTP connector Unshielded twisted pair connector f...

Страница 7: ...cur The Host Site The Remote Site RC908 EV35 RC908 EV35 RC908 EV35 RC907 EV35 2 2 Typical Applications Interface Converter 10Base T V 35 DDN V 35 ase T Ethernet switch m DDN leased line is utilized to...

Страница 8: ...ing different network equipment The working mode of other network equipment RC907 908 EV35 working mode 10Mbps full duplex The interface converter shall be configured to full duplex mode when auto neg...

Страница 9: ...P to connect the Ethernet port of RC907 908 EV35 interface converter and make sure that the length of the UTP cable does not exceed 100m NO 1 pin NO 8 pin The pin definitions of the RJ45 interface on...

Страница 10: ...5 interface adopts HDB26 female connector the definitions are as follows Pin Name Input Output Pin Number Chassis Ground CGND 1 Signal Ground GND 7 Receive Data A RD A I 3 Receive Data B RD B I 21 Rec...

Страница 11: ...orking temperature 0 45 Humidity 5 90 non condensing 7 Power supply AC DC optional AC 220V 50Hz input ranges form 165 to 265V DC 48V input ranges from 36 to 72V Power consumption 5W 8 Dimensions for R...

Страница 12: ...Mbps full duplex mode 10Mbps full half duplex auto negotiation Any 10Mbps full duplex mode Since the Ethernet interface of RC907 908 EV35 works at 10Mbps full half duplex mode auto negotiation it cann...

Страница 13: ...etween different brands DCE equipment OFF positive phase default ON negative phase m The 7th bit RX CLK phase selection switch It provides various options for different phase relationships of receivin...

Страница 14: ...switch are set to the factory default status network management software can command configure and inquire the status of the interface converter Otherwise the software has the inquiry function only A...

Страница 15: ...inuously but the equipment cannot be pinged through Answer In most cases the reason is that the interface converter is connected with 100Mbps network equipment RC907 908 EV35 can only connect with 10M...

Страница 16: ...onnection occurs it is abnormal Please check the operation condition of equipments To improve the network efficiency both the Ethernet equipment and the interface converter shall be set in full duplex...