Dynamix ITM Series Скачать руководство пользователя страница 4

R16 122016

 

 

 

Operation Instructions 

Please Read These Warnings Carefully Before Operating the Mixer 

 

 

WARNING!

 

 

The following safety instructions must be COMPLETELY REVIEWED 

AND FOLLOWED before operating any Dynamix Mixer. FAILURE TO  

FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY 

 

 
 
Important:

  This  instruction  manual  is  not  intended  to  include  a  comprehensive  listing  of  all  details  for  all  procedures 

required for installation, operation and maintenance. If you have a question about a procedure or are uncertain about any 
detail, Do Not Proceed. Please contact Dynamix Agitators for more information or clarification. 

 

1. 

Do  not  uninstall  or  service  this  mixer  until  you  have  followed  your  “Control  of  Hazardous  Energy  Sources” 
procedure as per OSHA Guidelines, and the Canadian Occupational Health and Safety Regulations. 

2.  Read and fully understand the manual before installation and startup. 

3.  Ensure  the  mixer  is  designed  for  the  application.  Operating  outside  of  the  mixer's  intended  use  will  result  in 

damage. Refer to original quotation. 

4.  Do not handle the mixer by the shaft. Lifting and handling the mixer by the shaft will cause damage. 

5.  Check the straightness of the shaft by slowly rotating by hand before operation in fluid. 

6.  On start-up jog the mixer in order to ensure the mixer shaft and impeller is not obstructed from rotation. 

7.  Fluid  level 

must 

be  a  minimum  of  the  equivalent  to  one  diameter  above  the  impeller  for  proper  mixing. 

Avoid 

operating the mixer in air.

 

8.  Avoid extended operation when fluid level is at or near the bottom impeller 

9.  Fluidize settled solids before starting mixer. Impeller  cannot  be buried in solids  at startup. For best performance 

axial flow impellers (Dynaflow

TM

 and Pitch) should be positioned ½ of their diameter above the tank floor or settled 

solids.  

10.  If the impeller is buried, disperse any settled solids before starting the mixer. This may be done using an air hose, 

re-circulating pump, or a large stick. 

11.  When  viewed  from  above  (looking  into  the  tote  container),  tote  mixer  rotation  is  counter  clockwise.  Improper 

direction  will result in minimal mixing.  If the Drive segment rotates during  operation  the mounting  nut  is not tight 
enough. If rotation continues please contact your Dynamix Salesperson. 

12.  Vortexing may occur if the fluid level is too close to the impeller. Aeration of the product and excess vibration may 

occur.  

13.  When mixing  materials  of  different  viscosities  or  specific  gravities,  the  lighter  or  less  viscous  material  should  be 

introduced first. Add heavier materials gradually in the center of the tank while the mixer is running. 

Do not dump 

large  quantities  of  solids  or  powders  into  the  tank. 

This will cause impacting on the impeller and may cause 

equipment damage. 

14.  Check the quotation data sheet for operating speed requirements if a variable speed drive is used 

15.  Reversed rotation may cause overloading and inefficient mixing. Confirm rotation with sticker on side of mixer. 

16.  Some shaft vibration is normal. A bent shaft may cause excess vibration.  

17.  Keep  motors  clean  and  dry.  Air  motor  intakes  and  exhaust  ports  must  be  clear  of  foreign  material.  The  electric 

motors supplied are designed for outdoor use, but may be damaged due to weather. A rain cover may be added 
to extend motor life. 

18.  Do not run air motors above 2000 RPM. 

See  Page  13 

for proper air consumption and pressure charts. See the 

Technical Drawing 

for the motor size. 

 
 

Содержание ITM Series

Страница 1: ...the enclosed information Table of Contents Important Safety Warnings 2 Receiving Inspection Storage 3 Operation Instructions 4 Startup Checklist 5 Assembly Installation Plastic Tote 6 Stainless Steel...

Страница 2: ...the mixer in a manner other than the mixers intended application 6 This mixer is intended for professional use only 7 Do not alter or modify this mixer 8 Do not uninstall or service this mixer until y...

Страница 3: ...iately to the carrier and to Dynamix Agitators Inc 3 Check all parts against packing list to verify that all parts have been received Report any missing parts to Dynamix Agitators Inc 4 The Dynamix Fa...

Страница 4: ...er Impeller cannot be buried in solids at startup For best performance axial flow impellers Dynaflow TM and Pitch should be positioned of their diameter above the tank floor or settled solids 10 If th...

Страница 5: ...mpeller s installed correctly See Installation Section 6 Impellers spaced correctly if two or more for maximum and minimum liquid levels 7 Impeller immersed in liquid and no equipment or obstructions...

Страница 6: ...plate mount seats onto the lip of the tote opening The outside diameter of the tote opening should not be greater than the outside diameter of the lip of the tote neck Attention No part of the impelle...

Страница 7: ...2 Thread Dynamic Coupling A male end in a clockwise direction onto protruded threads of the bearing housing See Reference 1 below Tighten the coupling A solidly with a non metallic hammer Step 3 Slide...

Страница 8: ...RING 51 001009 7 RETAINING NUT Refer to mixer serial no or sales person to confirm specs 8 SHAFT ASSEMBLY REBUILD KIT Refer to mixer serial no or sales person to confirm specs 9 SHAFT ASSEMBLY HOUSING...

Страница 9: ...ial no or sales person to confirm specs 5 DYNAMIC COUPLER MALE 50 701004 6 DYNAMIC COUPLER O RING 51 001009 7 STAINLESS STEEL LID Refer to mixer serial no or sales person to confirm specs 8 SHAFT ASSE...

Страница 10: ...erious or fatal injury Only qualified personnel should attempt the installation operation and maintenance of this equipment WARNING Do not touch electrical connections before you first ensure that pow...

Страница 11: ...e electric motors may be pre wired with a six 6 foot electrical cord If not provided follow the wiring diagram on the motor for proper connections Ensure the switch is in the OFF position before conne...

Страница 12: ...esigned to operate with a maximum air pressure of 100 psi If higher air pressure is supplied an in line air pressure regulator should be used to reduce the pressure This can also be used to vary the s...

Страница 13: ...13 Air Motor Horsepower Rating Air Consumption For Air Motors Rated at 1 5HP For Air Motors Rated at 4HP Note Output rpm refers to motor output shaft only For gear reduced drives refer to gear ratio o...

Страница 14: ...4 244 3771 Air Motor 1 5HP Rating Exploded views are shown for reference only Units may vary depending upon specific model Please refer to factory if you are unsure of your model Denotes parts include...

Страница 15: ...cific model Please refer to factory if you are unsure of your model Denotes parts included in the Service Kit REF DESCRIPTION QTY 1 Drive End Cap 1 2 Shaft Seal 1 3 O Ring 1 4 Drive End Bearing 1 5 Do...

Страница 16: ...ine on the correct port on reversible motors for proper rotation direction Gear Driven Gear Driven mixers are lubricated at the factory using the proper type and amount of lubricant for normal service...

Страница 17: ...Not Fit Into Drive Shaft over size proper diameter 0 001 0 002 under normal diameter Measure and consult factory Wrong end of shaft only one end fits Install end marked motor end 2 Coupling bolts are...

Страница 18: ...REPRESENTATIVES HAVE NO LIABILITY TO CUSTOMER FOR ANY DIRECT INDIRECT SPECIAL PUNITIVE INCIDENTAL OR CONSEQUENTIAL DAMAGES OR DELAY WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOST OR INTERRUP...

Страница 19: ...omer that the Product will perform substantially in accordance with the features and Solution Assurance as set out in the Quotation and be free from defects in materials and workmanship under normal u...

Страница 20: ...MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE OR USE In addition we do not assume and we expressly disclaim any liability for i any SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES which...

Страница 21: ...Branch order number serial number c Product Model number d Equipment installation date e Equipment failure date f Application or service of unit g Details of claim Dynamix will notify the customer whe...

Страница 22: ...R16 122016 20...

Страница 23: ...odel Number Serial Number Purchase Order Number Date Received Tank Number or Location Agitator Start Up Data Date of Installation Voltage at Start Up V DD MM YYYY Full Load amperage measured with amme...

Отзывы: