Dynamix ITM Series Скачать руководство пользователя страница 1

R16 122016

 

 

 

 

 

 

 

    

  

Installation, Operation & Maintenance Manual 

 

 

 
 
  

ITM Series

 

   

INTEGRATED TOTE MIXER

 

 

 

Important Safety Instructions 

 
This Installation and Operation Manual Includes  

Important Warnings and Safety Information. 

 
Be sure to keep this manual with equipment and  
ensure 

all operators

 read the enclosed information.

 

 
 

Table of Contents 

 

Important Safety Warnings.............................. 2 

Receiving, Inspection & Storage ..................... 3 

Operation Instructions ..................................... 4 

Startup Checklist ............................................. 5 

Assembly & Installation 

Plastic Tote ......................................... 6 

Stainless Steel Tote ............................  7 

Parts, Maintenance & Service 

Plastic Tote ......................................... 8 

Stainless Steel Tote ............................ 9 

Terms & Conditions ........................................ 16 

Warranty ......................................................... 17 

 

 

 

ITM SERIES 

Integrated Tote Mixer

 

 
 
     

Dynamix Agitators Inc. 

 

 
      150 - 14480 River Road,  
      Richmond, B.C, Canada V6V 1L4 
      Ph. 604.244.3771   Fax 604.244.3772 
 
      

[email protected]

 

      

www.dynamixinc.com

 

Содержание ITM Series

Страница 1: ...the enclosed information Table of Contents Important Safety Warnings 2 Receiving Inspection Storage 3 Operation Instructions 4 Startup Checklist 5 Assembly Installation Plastic Tote 6 Stainless Steel...

Страница 2: ...the mixer in a manner other than the mixers intended application 6 This mixer is intended for professional use only 7 Do not alter or modify this mixer 8 Do not uninstall or service this mixer until y...

Страница 3: ...iately to the carrier and to Dynamix Agitators Inc 3 Check all parts against packing list to verify that all parts have been received Report any missing parts to Dynamix Agitators Inc 4 The Dynamix Fa...

Страница 4: ...er Impeller cannot be buried in solids at startup For best performance axial flow impellers Dynaflow TM and Pitch should be positioned of their diameter above the tank floor or settled solids 10 If th...

Страница 5: ...mpeller s installed correctly See Installation Section 6 Impellers spaced correctly if two or more for maximum and minimum liquid levels 7 Impeller immersed in liquid and no equipment or obstructions...

Страница 6: ...plate mount seats onto the lip of the tote opening The outside diameter of the tote opening should not be greater than the outside diameter of the lip of the tote neck Attention No part of the impelle...

Страница 7: ...2 Thread Dynamic Coupling A male end in a clockwise direction onto protruded threads of the bearing housing See Reference 1 below Tighten the coupling A solidly with a non metallic hammer Step 3 Slide...

Страница 8: ...RING 51 001009 7 RETAINING NUT Refer to mixer serial no or sales person to confirm specs 8 SHAFT ASSEMBLY REBUILD KIT Refer to mixer serial no or sales person to confirm specs 9 SHAFT ASSEMBLY HOUSING...

Страница 9: ...ial no or sales person to confirm specs 5 DYNAMIC COUPLER MALE 50 701004 6 DYNAMIC COUPLER O RING 51 001009 7 STAINLESS STEEL LID Refer to mixer serial no or sales person to confirm specs 8 SHAFT ASSE...

Страница 10: ...erious or fatal injury Only qualified personnel should attempt the installation operation and maintenance of this equipment WARNING Do not touch electrical connections before you first ensure that pow...

Страница 11: ...e electric motors may be pre wired with a six 6 foot electrical cord If not provided follow the wiring diagram on the motor for proper connections Ensure the switch is in the OFF position before conne...

Страница 12: ...esigned to operate with a maximum air pressure of 100 psi If higher air pressure is supplied an in line air pressure regulator should be used to reduce the pressure This can also be used to vary the s...

Страница 13: ...13 Air Motor Horsepower Rating Air Consumption For Air Motors Rated at 1 5HP For Air Motors Rated at 4HP Note Output rpm refers to motor output shaft only For gear reduced drives refer to gear ratio o...

Страница 14: ...4 244 3771 Air Motor 1 5HP Rating Exploded views are shown for reference only Units may vary depending upon specific model Please refer to factory if you are unsure of your model Denotes parts include...

Страница 15: ...cific model Please refer to factory if you are unsure of your model Denotes parts included in the Service Kit REF DESCRIPTION QTY 1 Drive End Cap 1 2 Shaft Seal 1 3 O Ring 1 4 Drive End Bearing 1 5 Do...

Страница 16: ...ine on the correct port on reversible motors for proper rotation direction Gear Driven Gear Driven mixers are lubricated at the factory using the proper type and amount of lubricant for normal service...

Страница 17: ...Not Fit Into Drive Shaft over size proper diameter 0 001 0 002 under normal diameter Measure and consult factory Wrong end of shaft only one end fits Install end marked motor end 2 Coupling bolts are...

Страница 18: ...REPRESENTATIVES HAVE NO LIABILITY TO CUSTOMER FOR ANY DIRECT INDIRECT SPECIAL PUNITIVE INCIDENTAL OR CONSEQUENTIAL DAMAGES OR DELAY WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOST OR INTERRUP...

Страница 19: ...omer that the Product will perform substantially in accordance with the features and Solution Assurance as set out in the Quotation and be free from defects in materials and workmanship under normal u...

Страница 20: ...MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE OR USE In addition we do not assume and we expressly disclaim any liability for i any SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES which...

Страница 21: ...Branch order number serial number c Product Model number d Equipment installation date e Equipment failure date f Application or service of unit g Details of claim Dynamix will notify the customer whe...

Страница 22: ...R16 122016 20...

Страница 23: ...odel Number Serial Number Purchase Order Number Date Received Tank Number or Location Agitator Start Up Data Date of Installation Voltage at Start Up V DD MM YYYY Full Load amperage measured with amme...

Отзывы: