Dynaluxx Venus V290 Скачать руководство пользователя страница 2

Wiring

Sensor

L

N

L

N

Sensor On-off/dimming setting options 

For code V290 18 SOF/ V290 18 SDM/ V290 18 STM)

Hol d-t i me

5s ~30mi n 

Detection area can be reduced by selecting the 

combination on the DIP switches to fit precisely for 

each specific application.

Detection area

I –  

100%

I I –   50%

1

I

II

50%

100 %

Hold-time means the time period you would like to 

keep the lamp on 100% after the person has left the 

detection area.

I –  5s

I I –  30s

I II –  3min 

I V – 10min

30s

5s

10min

3

2

I

II

III

IV

3min

I –  Disable

I I –    

50Lu x

I II  – 10Lu x

I V – 2Lux

Daylight sensor

The daylight threshold can be set on DIP switches, 

to fit for particular application.

5

4

50Lux
10Lux

2 Lux

Disabl

e

I

II

III
IV

I   –  

 10%

I I –   30%

8

I

II

30%

10%

This is the dimmed low light output level you would 

like to have after the hold-time in the absence of 

people.

Stand-by dimming level

Hold-time

2~50L ux

St and- by per iod

0s ~+ 8

I  –  0s

II   –  3 0s

I II  –  10m in 

I V –  + ∞

This is the time period you would like to keep at the 

low light output level before it is completely switched 

off in the long absence of people.

Stand-by period (corridor function)

30s

0s

+∞

7

6

I

II

III

IV

10min

Note: “0s” means on/off control;

         “+    ” means bi-level dimming control, fixture 

          never switches off.

8

5m

8m

1.Do like (6-1),knock out the entrance from the 

cover and cut off by outline

2.One-to-one correspondence between the position 

of the knock out hole of the cover and the position of 

the base, then do like (6-2) lock the screws

3.Open the power grid.

1.Fit the diffuser to the 

base and lock the screws

2.Open the power grid.

1

.

Fix the cover on the buckle 

of the chassis

2.The cable goes from the 

bottom of the fixture, follow 

the (5) do finish the next step

3.The cable goes from the side 

of the fixture, follow the (6-1) 

(6-2)do finish the next step.

Detection Pattern

ceiling mounting pattern (m)

5m

8m

wall mounting pattern (m)

9m

4m

Caution:

1. Cut off the main power first
2. Don’t touch LEDs while maintaining or cleaning
3. Don't use chemicals to clean the fixture.

Environmental protection: waste electrical products should not be disposed of with household waste. Please recycle 
where facilities exist. Check with your local authority or retailer for recycling advice.

Maintenance

RoHS

IK10

IP65

SAA

TM

1. The product must be installed by professional technicians and power supply must be cut off before installation.
2. The diameter for AC input wire is 0.75mm² (complying with 60245 IEC57), which complies with the latest IEE
electrical standards or national standards.
3. Do not touch the electronic circuit and its components.
4. Contact an authorised technical service centre for any repairs possibly required use only original spare parts.
5. Do not touch LED while installing or maintaining.
6. After installation, remember to seal the entrance hole with glue.


7. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a 

similar qualified person.

Отзывы: