3101B-TJ101 MANUAL

03/11

MODEL 3101B-TJ101

DELAY EGRESS SYSTEM

WIRING  INSTRUCTIONS

705 Emmett Street    Bristol, CT 06010

 1-877-DynaLock    www.dynalock.com

INDICATOR & AUDIBLE DESCRIPTIONS

LED2 - WATCHDOG LED INDICATOR

(Located upper right corner of circuit board.)

Troubleshooting indicator - monitors proper 

operation of the microprocessor. 

LED1 - BI-COLOR LED INDICATOR

(Located on 7050 faceplate.) 

Indicates lock status and monitors 

door movement during egress sensor 

adjustment.

SEPERATE 7050 KEYSWITCH OPERATION

CENTER

CLOCKWISE (SPRING LOADED)

COUNTER-CLOCKWISE

NORMAL / LOCKED

RESET AFTER DELAY EGRESS ALARM

BYPASS / UNLOCKED WITHOUT ALARM

POSITION

DESCRIPTION

CONDITION

AUDIBLE SIGNAL

LOCK 

LED 1

LED 2

DELAY EGRESS ALARM

One second pulse rate during 

delay cycle.

ON

BLINK RED

RED

DELAY EGRESS ALARM

Steady tone after delay until 

reset.

OFF

GREEN

RED

FIRE ALARM

RELEASE

Steady tone until fire alarm 

contacts are reset.

OFF

GREEN

RED

OPTIONAL REMOTE

AUTHORIZED BYPASS

(TERMINALS 7&8 / 9&10)

None, unless bypass audible 

is enabled (dip switch 2).  If 

door is held open past relock 

time, goes into delay egress 

alarm & requires reset.

OFF

GREEN

RED

FACTORY SERVICE

REQUIRED

Steady tone.

N/A

N/A

BLINK RED 

OR OFF

POOR MAGNETIC BOND Rapid pulse rate until problem 

is corrected (only functional 

with Dynastat Force Sensor 

option).

N/A

FAST BLINK RED RED

Содержание 3101B-TJ101

Страница 1: ...MODEL 3101B TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS 705 Emmett Street Bristol CT 06010 1 877 DynaLock www dynalock com ...

Страница 2: ... fire alarm control jumper J9 is properly set to match your fire panel input contacts If fire panel tie in is not required leave jumper at factory setting N O Remove the Electronics Cover to expose the circuit board assembly Factory Setting Factory Setting 1 2 3 System Selector Switches The selector switches DS1 that control major system functions are factory set to the OFF position for basic lock...

Страница 3: ...r 9 10 SEE PAGE 11 Terminals 3 4 Fire Panel Input May be normally open N O or normally closed N C dry contacts from fire panel check fire alarm control jumper FA page 1 When the fire panel trips the 3101B TJ101 will release the audible will sound a constant tone and the bi color LED LED1 will change to green When the fire panel is reset the 3101B TJ101 will reset and lock NOTE DO NOT APPLY POWER T...

Страница 4: ...ion later With the door closed observe the bi color LED LED1 on the circuit board It should be lit red If it is not lit rotate the adjustment wheel counter clockwise as necessary to ensure that it will contact and fully depress the ball plunger on the lock Rattle the door to ensure the LED remains lit With the door closed and LED1 lit red unlatch and slowly open the door The LED will shut off as s...

Страница 5: ...AL LOCKED RESET AFTER DELAY EGRESS ALARM BYPASS UNLOCKED WITHOUT ALARM POSITION DESCRIPTION CONDITION AUDIBLE SIGNAL LOCK LED 1 LED 2 DELAY EGRESS ALARM One second pulse rate during delay cycle ON BLINK RED RED DELAY EGRESS ALARM Steady tone after delay until reset OFF GREEN RED FIRE ALARM RELEASE Steady tone until fire alarm contacts are reset OFF GREEN RED OPTIONAL REMOTE AUTHORIZED BYPASS TERMI...

Страница 6: ...ss your specific system requirements The normal factory setting is all switches off 1 Sensor Control The egress sensor may be disabled if you wish to trigger the lock via external remote contacts on input terminals 11 12 Position jumper J10 to disable the egress sensor as shown 3 Factory Setting C S A C A S 1 SYSTEM SET UP NORMAL SET UP MODE 2 BYPASS AUDIBLE DISABLED ENABLED 3 NUISANCE DELAY 1 SEC...

Страница 7: ...nd the 7050 key switch These leads must be connected to match the same color flying leads coming from the 7050 LED See above illustration Remember to observe polarity for either the key switch or LED s three wire harness The key switch must be connected with the blue wire facing the left WHITE BLACK BLUE See above illustration The LED 1 must be connected with the green wire facing the left GREEN B...

Страница 8: ...ndant or substitute means of triggering delayed egress if built in sensor initiation is not desired INPUT DESCRIPTIONS WARNING DO NOT APPLY POWER TO INPUTS MARKED OR DAMAGE WILL OCCUR A C B D REMOTE BYPASS INPUT TIME DELAY Momentarily closing a normally open dry contact across terminals 9 10 will immediately release the lock without alarm The door will remain unlocked for a period of time controll...

Страница 9: ...nt can also create an unsecure condition DSM OPTION OUTPUT Door position sensor monitoring SPDT dry relay contacts rated 0 5Amp 24 Volts Contacts change state to signal physical door position as either closed or open DSM is an independent circuit that does not require lock power to operate ATS OPTION OUTPUT Anti Tamper Switch monitoring SPDT dry relay contacts rated 0 5Amp 24 Volts Contacts change...

Страница 10: ...r and or DSM Door Status Switch Options Observe polarity when re connecting the J5 and J8 harness connectors Orient these connectors with respect to harness wire colors as follows 1 2 3 4 NOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 STANDARD SOFTWARE VERSION 2K1 1 J4 J3 3101B TJ101 CIRCUIT BOARD COIL HARNESS 4 COND SENSOR HARNESS 4 COND SENSOR COVER ASSEMBLY DYNATSTAT FORCE...

Страница 11: ...Page 11 3101B TJ101 MANUAL 03 11 MODEL 3101B TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS 705 Emmett Street Bristol CT 06010 1 877 DynaLock www dynalock com INSTALLER NOTES ...

Страница 12: ...FOR PRODUCT SUPPORT AND PARTS ORDERING INFORMATION CONTACT DynaLock Corp 705 Emmett Street Bristol CT 06010 Bus 877 396 2562 Toll Free USA 860 582 4761 Fax 860 585 0338 DYNALOCK ON THE INTERNET E mail info dynalock com Website www dynalock com GWXT Auxiliary Lock FWAX Special Locking Arrangements CSFM California State Fire Marshal ...

Отзывы: