Always install the carrier or platform before turning on the machine.  All platforms or 
carriers are shipped in pre-installed status.  For safety reason, please check all the locking 
screw and tighten again if necessary.  The locking screws might be loosened during 
transportation! 

Place the machines on the flat and steady surface and keep away from other objects for 
safe operation. 

Check the electrical safety status and the power switch must be in “OFF” position before 
plug into the power outlet.  The machines come with IEC electrical socket and double fuses 
for safety operation.  

For the 3D Gyrator Rockers, adjust the tilted angle before loading the samples.  Set the 

speed to the minimum rpm.  And examine the nut underneath the center cylinder shaft 

turning front, then stop the machines and tilt the platform to desired angle. 

 

Figure 13: Overview of head box . 

Load the samples first before turning on the machine.  Be aware of loading sample evenly 
and never overload the samples. 
Always start with low speed and gradually adjust the speed, especially for the analog 

model. 

There are two different types of control in most of the mixers:  digital and analog.  Both 
control modes can adjust the speed and timer of the mixers. 

1.  Digital Control of Speed and Timers 

 

Figure 14: Overview of the front panel of the digital control mode.  ①Start/stop 
button; ②Mode button; ③Indicator beneath “rpm”; ④ Indicator beneath “time” 

 

There are two buttons and one knob on the digital panel:  The 

knob

 is the main switch for 

turning on the machine and adjusting the speed and timer; the 

mode

 button has the 

Содержание DGRL-01-01

Страница 1: ...1 Rockers DGRL DGRM DSRL DSRM series OPERATING MANUAL Dynalab Corp November 2017 DGRL 01 01 DGRM 01 02 ...

Страница 2: ...2 BEFORE USE Please read the following instructions Warning Check the line supply is sufficient to meet the power requirement of the unit ...

Страница 3: ...OR ANY DAMAGE OF AN INDIRECT OR CONSEQUENTIAL NATURE ARISING OUT OF OR RELATED TO ITS PERFORMANCE WHETNER BASED UPON BREACH OF AGREEMENT WARRANTY OR NEGLIGENCE AND WHETHER GROUNDED IN TORT CONTRACT CIVIL LAW OR OTHER THEORIES OF LIABILITY INCLUDING STRICT LIABILITY EVEN IF ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES THE COMPANY S TOTAL LIABILITY INCLUDING BUT NOT LIMITED TO LIABILITY FOR...

Страница 4: ...ation type and the wave type With tilted angle in one end the gyration mixers gyrate in three dimension This mixing action is suitable for full flashing some floated object by liquid such as staining and de staining gels and low foaming mixing purpose The wave type is based on see saw action to create wave like mixing of the liquid and suitable for Petri dish and culture fl ...

Страница 5: ...he mini scale 3D gyrator rocker RCK 31 Electrical socket Slip proof platform LED display on Digital front panel Figure 5 Overview of the lab scale see saw rocker RCK 21 Electrical socket Slip proof platform Digital front panel ...

Страница 6: ...the minimum rpm And examine the nut underneath the center cylinder shaft turning front then stop the machines and tilt the platform to desired angle Figure 13 Overview of head box Load the samples first before turning on the machine Be aware of loading sample evenly and never overload the samples Always start with low speed and gradually adjust the speed especially for the analog model There are t...

Страница 7: ...uminate turn the knob to desired count down minute To disable the timer just turn the knob to the unit will continuously operate until manually stopping the unit When the timer reaches to zero the unit stops and sounds an alert The default time unit is minute displayed nnnn but it can be changed to Hour Minute displayed H nn or Minute Second displayed nn ss To do so turn off the machine completely...

Страница 8: ...ttom panel is for the control of speed and timing which is exactly the same setting procedures describe above and the top control panel is for temperature control see Figure 16 To set the temperature hold the set button and turn the knob to the desired temperature After release the set button the temperature setting takes in effect immediately For CMI 100 the temperature can only be set from 5 C a...

Отзывы: