en | Connector panel CP34
TGX Amplifier System Rack
2019-03 | 02 | F.01U.346.534
Installation manual
Bosch Security Systems, Inc.
Figure
6.6: OMNEO / Dante / OCA connection of multiple system racks with primary and secondary line
If no Dante audio signal is used, or as an additional (third level) back-up, digital audio signal in
AES3 format can also be connected throughout multiple racks by daisy-chaining.
Figure
6.7: AES3 digital audio signal connection of multiple racks
In addition to the OMNEO cabling audio signal can be fed as digital signal in AES3 format as
well as analogue line level. Note the AES3 format is using 2 signals on one connector, which is
B for amplifier channels A & B and D for amplifier channels C & D.
The same schematic applies to analogue line level signals, just with one signal per connector.
Notice!
For reliable performance it is important to use only high-quality cabling throughout the entire
system. System performance is depending on the entire cabling to work within specifications.
System performance is depending on the entire cabling to work within specifications. For
network cabling shielded cables with at least CAT5e specification must be used, we
recommend to use shielded CAT6 cabling.