Number Symbol Element
Description
3
Recessed button
The button is protected to prevent it from being
pressed accidentally. Use a pointed object (such as
a ballpoint pen) to press the button.
This button has the following functions if the CAN
address of the device is not set to 00:
•
Find function: If the find function of the device
is activated, press this button to deactivate the
indicators.
•
Displaying the CAN baud rate: Press this button
for at least one second. Please refer to section
Displaying the CAN baud rate, page 24.
•
LED test: Press this button for at least three
seconds to activate the LED test. All indicators
at the front panel light up as long as the button
is pressed.
This button has the following functions if the CAN
address of the device is set to 00 (stand-alone
mode):
•
Resetting a ground fault or watchdog fault:
Press the button briefly to confirm a watchdog
fault or ground fault (stand-alone mode only,
please refer to section Stand-alone mode, page
25)
•
Setting/displaying the CAN baud rate: Press this
button for at least one second. Please refer to
section Configuring the CAN baud rate, page
24.
•
Resetting to delivery condition: To reset all
settings to their original configuration on
delivery, press this button for at least three
seconds to reset all device settings.
4
Ground fault
indicator light
This indicator lights up yellow when a ground fault
has occurred at least one output. The indicator
remains illuminated even when the ground fault has
been resolved. To deactivate the indicator, press the
Recessed button (3) or use IRIS-Net. Please refer to
section Stand-alone mode, page 25.
5
Audio signal
indicator light
This indicator lights up green if an audio signal
(signal level > -36 dB) is present at the power
amplifier input.
6
Network indicator
light
This indicator lights up green in the event of
successful data communication with the controller.
10
en | System overview
Promatrix 6000 Amplifier
18-Jun-2015 | 04 | F01U306848
Operation manual
Содержание Promatrix 6000 PMX-2P500
Страница 1: ...Promatrix 6000 Amplifier PMX 2P500 en Operation manual...
Страница 2: ......
Страница 31: ...Dimensions 10 3 Promatrix 6000 Amplifier Technical data en 31 Operation manual 18 Jun 2015 04 F01U306848...
Страница 33: ......