background image

DIGITAL SYSTEM AMPLIFIER

6    Owner‘s Manual

HF-Interference (FCC Information USA)

1. IMPORTANT: Do not modify this unit! Changes or modifications not expressly approved by the manufacturer could void the
user‘s authority, granted by the FCC, to operate the equipment.

2. NOTE:This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection agains harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

Consult the dealer or an experienced radio/TV technician for help

This Class A digital apparatus complies with Canadian ICES-003.

Cat appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

WARNING:
The terminals marked with   are hazardous live and the external wiring connected to these
terminals requires installation by an instructed person or the use of ready-made leads of
cords.

This is a Class A product. In a domestic environment this product may cause radio inter-
ferences in which case the user may be required to take adequate measures.

Содержание Power Amplifier DSA 8204

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG...

Страница 2: ......

Страница 3: ...de POWER REMOTE 13 Fan Cooling 13 Options 14 RCM 810 14 INHALT Einf hrung 19 Willkommen 19 Auspacken und Inspektion 19 Lieferumfang und Garantie 19 Eigenschaften Beschreibung 19 Verantwortung des Betr...

Страница 4: ...0065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be...

Страница 5: ...ty Certificate Keep the original invoice that states the purchase delivery date together with the warranty certificate at a safe place 1 4 Features and Description Dynacord DIGITAL SYSTEM AMPLIFIER Se...

Страница 6: ...s equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by on...

Страница 7: ...Indicator POWER 5 Standby Indicator STANDBY 6 Remote Amplifier Indicator IRIS Net 7 Mains Switch 1 Mains Input 2 Ground Lift Switch CIRCUIT TO CHASSIS SWITCH 3 POWER REMOTE connector 4 Power On Delay...

Страница 8: ...ich otherwise might be heard through the loudspeakers PROT LED light and fans are at high speed during this delay This indicates all protections are working fine 2 4 Mounting DSA amplifiers have been...

Страница 9: ...mers Set the switch to the 50Hz position for activating the High Pass Filter Set the switch to the OFF position if no attenuation of low frequency audio signals is required 2 8 Power on delay The ON D...

Страница 10: ...cting speakers in DUAL or PARALLEL mode The correct connection is also indicated at the amplifiers rear panel BRIDGED In BRIDGED mode both amp channels work in push pull operation to provide doubled o...

Страница 11: ...ing signals are to be expected in the vicinity of the power amplifier In this case bridging the screen shielding and the pin of the inverting input inside of the connector is mandatory Otherwise a 6 d...

Страница 12: ...tical LED chains on the power amp s front panel that individually indicate the actual levels of each channel at 30dB 10dB and 3dB below full modulation The LIMIT LED lights as soon as the integrated d...

Страница 13: ...E is not recommended Leaving the pins of POWER REMOTE socket open the appliance power is switched on When connecting the pins the applicance enters standby mode 3 4 Fan Cooling The power amplifier has...

Страница 14: ...ng an automatic reaction when specific thresholds are being exceeded or fallen below is also possible All parameters like power on off muting etc can be controlled in real time and stored in the ampli...

Страница 15: ...the remote network Cabling in a rack system can be established using commercially available RJ 45 network cables However CAN guidelines have to be observed for longer cable lengths Both ends of the CA...

Страница 16: ...ys to connect them to ground potential pin 3 The two control outputs OUT1 and OUT2 are open collector outputs which are highly resistive in the non active state off In active state on the outputs are...

Страница 17: ...DIGITAL SYSTEM AMPLIFIER Owner s Manual 17...

Страница 18: ...rwendung durch qualifiziertes Servicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden f hren Sie keine Wartungsarbeiten durch die nicht in der Bedienungsanleitung beschrieben sind au er...

Страница 19: ...ie DSA Endstufen sind damit der ideale Antrieb f r typische Anwendungen in der Festinstallation Die Endstufen der DSA Serie sind gegen berhitzung berlast Kurzschluss sowie Hochfrequenz und Gleichspann...

Страница 20: ...e Betrieb POWER 5 Anzeige Standby STANDBY 6 Anzeige Remote Amplifier IRIS Net 7 Netzschalter 1 Netzeingang 2 Schalter Groundlift CIRCUIT TO CHASSIS SWITCH 3 POWER REMOTE Buchse POWER REMOTE 4 Einschal...

Страница 21: ...ber die Ausgangsrelais um ca 2 Sekunden verz gert zugeschaltet Hierdurch werden etwaige Einschaltger usche effektiv unterdr ckt die ansonsten in den Lautsprechern h rbar w ren W hrend dieser Verz geru...

Страница 22: ...erstellung 50Hz ist der Hochpassfilter aktiviert in Schalterstellung OFF ist der Hochpassfilter nicht aktiviert 2 8 Einschaltverz gerung ber den Einschaltverz gerungs Wahlschalter ON DELAY auf der R c...

Страница 23: ...ekte Anschlussweise f r diese Betriebsart ist zus tzlich auf der Endstufe selbst abgebildet BRIDGED In der Betriebsart BRIDGED werden die beiden Endstufenkan le im Gegentakt betrieben um eine Verdoppe...

Страница 24: ...warten sind kann auch ein unsymmetrisches Signal angeschlossen werden In diesem Fall ist es zwingend erforderlich eine Br cke im Eingangsstecker zwischen Schirm und dem invertierenden Eingang zu schal...

Страница 25: ...f r die beiden Kan le mit den jeweiligen LEDs 30dB 10dB und 3dB unter Vollaussteuerung Die LIMIT LED leuchtet auf sobald einer der eingebauten dynamischen Audio Limiter anspricht und die Endstufe ber...

Страница 26: ...den die Pins der POWER REMOTE Buchse offen gelassen so schaltet das Ger t ein Bei einer Verbindung der Pins schaltet das Ger t in den Standby Modus 3 4 L fter Die Endstufen der DSA Serie besitzen zwei...

Страница 27: ...danz usw werden in IRIS Net zentral erfasst und dargestellt Dadurch kann schon vor dem Auftreten von kritischen Betriebzust nden reagiert und gezielt eingegriffen werden Eine automatische Reaktion bei...

Страница 28: ...odul besitzt zwei RJ 45 Buchsen f r den REMOTE CAN BUS Die Buchsen sind parallel geschaltet und dienen als Eingang und zum Weiterschleifen des Remote Netzwerkes Zur Verkabelung innerhalb des Racks k n...

Страница 29: ...en Collector Outputs die im nichtaktiven Zustand Off hochohmig sind Im aktiven Zustand On sind die Ausg nge gegen Masse geschlossen Die Steuerausg nge werden ber IRIS Net konfiguriert und dienen zur S...

Страница 30: ...Gain ref 1 kHz 32 0 dB Input Sensitivity rated power 8 1 kHz 2 2 dBu 1 0 Vrms 3 1 dBu 1 11 Vrms 5 1 dBu 1 39 Vrms 6 6 dBu 1 66 Vrms THD at rated output power MBW 80 kHz 1 kHz 0 03 IMD SMPTE 60 Hz 7 kH...

Страница 31: ...Normal Mode 10 dB 4 3 230 3 0 450 80 370 1262 Rated Output Power 0 dB 4 3 230 7 6 1380 800 580 1979 Alert Alarm Mode 3 dB 4 3 230 5 7 1000 400 600 2047 Max Output Power 2 3 230 12 1 2250 1300 950 3242...

Страница 32: ...2 460 160 300 1024 Rated Output Power 0 dB 4 3 230 14 4 2640 1600 1040 3549 Alert Alarm Mode 3 dB 4 3 230 10 2 1770 800 970 3310 Max Output Power 2 3 230 21 6 4090 2800 1290 4402 1 8 Max Output Power...

Страница 33: ...DIGITAL SYSTEM AMPLIFIER Owner s Manual Bedienungsanleitung 33 5 2 Block Diagram Blockschaltbild...

Страница 34: ...DIGITAL SYSTEM AMPLIFIER 34 Owner s Manual Bedienungsanleitung 5 3 Dimensions Abmessungen...

Страница 35: ......

Страница 36: ...tems Telex EVI Audio Shanghai Ltd Room 3105 3109 No 1 Building No 218 Tian Mu West Road Shanghai China PC 200070 Phone 86 21 6317 2155 Fax 86 21 6317 3023 Europe Africa Middle East Germany Bosch Commu...