10.4.2 Online-Access to all Parameters
Via RS-232 connection and using REMOTE-commands provides direct access to all DRM 4000 parame-
ters, like routing, VCA, priority override, ducking, mute, etc. Controlling the unit is possible parallel to any
other control method (hardware contact switching, software contact switching, external VCA-control), with
any individual priority being recognized. For example, activating an external contact with a higher priority
setting overrides actual remote settings. As soon as deactivating the contact again, all previous remote
are regained.
Generally, all REMOTE-commands have the lowest priority (0) and all entries are set to NO_CHANGE.
The following table lists all REMOTE-commands and their corresponding parameter values.
Please be aware of the fact that all REMOTE-commands are transient and are set back to their default
values (NO_CHANGE, priority 0) upon switching the unit’s power on or after resetting the device.
ASCII-command
Comment
/SERVICE/HB
value
Value: 60 ... 0, OFF / ? (see above)
/SERVICE/CC/ON
value
Value: NONE, 1-8 / ? (see above)
/SERVICE/CC/OFF
value
Value: NONE, 1-8 / ? (see above)
/REMOTE/PRIO
value
e. g.:
/REMOTE/PRIO 100
/REMOTE/PRIO ?
Value: 0 ... 255 / ? ( 0 = lowest, 255 = highest priority)
Write access:
assigns a priority to REMOTE-commands.
Read access:
reads a REMOTE-command’s actual priority.
/EDIT/REMOTE/MIC_LINE1/ROUTING
value
e. g.:
/EDIT/REMOTE/MIC_LINE1/ROUTING MONO_A
/EDIT/REMOTE/MIC_LINE1/ROUTING ?
Value: NO_CHANGE, OFF, MONO_A, MONO_B, DUAL / ?
Write access:
sets the routing of MIC/LINE 1 via remote (mind
priorities!)
Read access:
reads the routing of MIC/LINE 1, which has been set via
remote.
/EDIT/REMOTE/MIC_LINE1/OVERRIDE
value
e. g.:
/EDIT/REMOTE/MIC_LINE1/OVERRIDE ON
/EDIT/REMOTE/MIC_LINE1/ OVERRIDE ?
Value: ON, OFF / ?
Write access:
activates or deactivates priority override of MIC/LINE 1
via remote (mind priorities!)
Read access:
returns the actual status.
...
ROUTING for MIC_LINE2 … MIC_LINE4 see MIC_LINE1
OVERRIDE for MIC_LINE2 see MIC_LINE1
/EDIT/REMOTE/MIC_LINE4/
...
...
/EDIT/REMOTE/AUX1
value
e. g.:
/EDIT/REMOTE/AUX1 STEREO
/EDIT/REMOTE/AUX1 ?
Value: NO_CHANGE, OFF, MONO_A, MONO_B, DUAL, STEREO / ?
Write access:
sets the routing of AUX 1 via remote (mind priorities!)
Read access:
reads the routing of AUX 1, which has been set via
remote.
...
…
/EDIT/REMOTE/AUX4
value
ROUTING for AUX2 … AUX4 see AUX1
/EDIT/REMOTE/OUT_A/MUTE
value
e. g.:
/EDIT/REMOTE/OUT_A/MUTE OFF
/EDIT/REMOTE/OUT_A/MUTE ?
Value: NO_CHANGE, ON, OFF / ?
Write access:
sets the status output relay in the MASTER A output via
remote (mind priorities!)
Read access:
reads the actual status.
/EDIT/REMOTE/OUT_A/DUCK
value
e. g.:
/EDIT/REMOTE/OUT_A/DUCK ON
/EDIT/REMOTE/OUT_A/DUCK ?
Value: NO_CHANGE, ON, OFF / ?
Write access:
sets the status of the ducking control in the MASTER A
output via remote (mind priorities!)
Read access:
reads the actual status.
/EDIT/REMOTE/OUT_A/LEVEL
value
e. g.:
/EDIT/REMOTE/OUT_A/LEVEL -10
/EDIT/REMOTE/OUT_A/LEVEL ?
Value: NO_CHANGE, -90 ... 0 / ?
Write access:
sets the VCA of the MASTER A output via remote to
the desired value (mind priorities!)
Read access:
reads the actual status.
...
...
/EDIT/REMOTE/OUT_B/
...
OUT_B settings see OUT_A
/EDIT/ACTUAL/...
e.g..: /EDIT/ACTUAL/MIC_LINE1/ROUTING?
Reads the actual states of the DRM 4000 like routing etc.
Only read access is recommended.
S P E C I F I C A T I O N S
10-6
Содержание DRM 4000
Страница 1: ...OWNER S MANUAL DRM 4000 8 IN 2 AUDIO MIXER ROUTER...
Страница 33: ...10 2 User Configuration SPECIFICATIONS 10 2...
Страница 34: ...SPECIFICATIONS 10 3...
Страница 35: ...10 3 Block diagram SPECIFICATIONS 10 4...
Страница 38: ...10 5 Dimensions SPECIFICATIONS 10 7...