mains operation remote control ON/OFF

battery operation remote control ON/OFF

monitoring and fault message transmission via the PROMATRIX Manager DPM 4000; in accordance
to DIN EN 60849 standard

thermal overload of the mains transformer

thermal overload of power output stages 1 to 4

monitoring of the functioning of the power output stages 1 to 4 via pilot tone signal (optional, only with
NRS 90206 installed)

ground fault detection for loudspeaker lines 1 to 4 (optional, only with NRS 90207 installed)

measuring of input and output level peaks 1 to 4 

measuring of output voltages / levels of the power outputs 1 to 4

measuring of output currents of the power outputs 1 to 4

monitoring of connected loads 1 to 4 via current-voltage-measuring 

recognition of amplifier type including user-definable name

reading of software revision of the remote module 

reading of error flags

reading of the output configuration

recognition of extensions NRS 90206 and NRS 90207 

switching the input monitor / output monitor 1 to 4 to the monitor bus 

pilot tone signal ON/OFF (optional, only with NRS 90206 installed)

ground fault error flags reset 

Note

Prior to the first operation of the amplifier DPA 4411, you have to set the amplifier address
using the two Hexadecimal Code switches ADDRESS (18) (refer to the PROMATRIX 

 

 handbook) and using a waterproof marker pen mark the setting in the ADDRESS label field 
on the rear panel of the appliance.

By sending the corresponding command via the serial port REMOTE CONTROL (13) of the remote
module, this function is activated from the PROMATRIX Manager DPM 4000 (see PROMATRIX
handbook).

7. Indicators And Fault Notification

7.1 STANDBY Indicator

When correctly connected and with mains voltage and/or battery voltage present, the green STANDBY
indicator (4) lights.

7.2 READY Indicator

The  power amplifier DPA 4411 provides a power-on delay of approximately 3 s to prevent switch clicks
from becoming audible. If after this period of time no faulty condition has been detected, the green READY
indicator (7) lights and the mute-relays pull. When thermal overload of the mains transformer or of one of
the power output stages is detected, the corresponding green READY indicator (7) will not light and the
according mute-relay drops. If, with the NRS 90206 extension installed the pilot-threshold (see paragraph
9.1) is declined, the corresponding green READY indicator (7) goes out but the amplifier stays operational
and a fault message gets transmitted to the PROMATRIX Manager DPM 4000.

7.3 PROTECT Indicator 

In case of thermal overload of the mains transformer or of a power output stage is detected, the red
PROTECT indicator (5) will light. During thermal overload of the mains transformer, all mute-relays drop
while during thermal overload of a power output stage, only the according mute-relay drops. After the
mains transformer or the power amplifier have regained their normal temperature, the red PROTECT
indicator (5) automatically goes out and the appliance recovers normal operation mode.  The faulty
condition could have been caused by either overload, too high environmental temperature, or by an error
in the ventilation system. A fault-message is transmitted to the PROMATRIX Manager DPM 4000.

27

Содержание DPA 4411

Страница 1: ...tted Monitor output transformer for balanced floating MONITOR output can be retrofitted Routing switch for parallel operation of the amplifier s inputs Integrated Standby Power Supply Mains function s...

Страница 2: ...into your outlet consult an electrican for replacement of the absolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the a...

Страница 3: ...TATUS indicator 15 INPUT connectors 1 4 16 ROUTING switch for INPUT 1 4 17 Device address label field 18 ADDRESS selector switch 19 POWER OUTPUT 20 Device output configuration label field 21 Air outle...

Страница 4: ...ndicators 28 7 6 STATUS Indicator 28 8 Switching The Output Voltage refer to qualified service personnel only 28 9 Additional Functions And Features refer to qualified service personnel only 29 9 1 NR...

Страница 5: ...our If a solid object has fallen or liquid has leaked into the device disconnect all connectors and get in contact with an authorized DYNACORD service center Do not operate the amplifier after such ac...

Страница 6: ...nding of the negative pole Operation with batteries with grounding of the positive pole is not permissible 4 Inputs INPUT 1 to INPUT 4 The inputs INPUT 1 to INPUT 4 15 are electronically balanced With...

Страница 7: ...s is recommended to reduce the lack in performance when the distance between amplifier and speaker systems exceeds 50 m This m ethod also offers an easy way to distribute the output power The total po...

Страница 8: ...channels of the DPA 4411 have to be set to equal values refer also to the PROMATRIX handbook This results in the following output combinations with a single DPA 4411 4 x 100 W or 2 x 100 W 1 x 200 W o...

Страница 9: ...e remote module this function is activated from the PROMATRIX Manager DPM 4000 see PROMATRIX handbook 7 Indicators And Fault Notification 7 1 STANDBY Indicator When correctly connected and with mains...

Страница 10: ...mpedance of the connected load Caution During normal operation the red CLIP LED 2 should hardly light and if than only very briefly 7 6 STATUS Indicator The yellow STATUS LED 14 that is located on the...

Страница 11: ...AMP 1 4 7 goes out but the power amplifier upholds its normal operation A fault message is transmitted to the PROMATRIX Manager DPM 4000 see PROMATRIX handbook The extension kit NRS 90206 comes as a...

Страница 12: ...The information ground fault is memorized as long as the amplifier is powered on or a loaded battery is connected even for short term 5 s ground faults The fault message is transmitted to the PROMATR...

Страница 13: ...331 you have to unscrew the two screws on the side panel before installing the input transformer make sure to unsolder the resistors for T1 R1 R5 for T2 R9 R13 for T3 R17 R21 for T4 R25 R29 and clean...

Страница 14: ...since the transformer is balanced reinstall the input printed board assembly 81331 following the description in paragraph 9 3 1 closing the appliance use the 9 screws M3 x 6 DIN 7500 to reattach the c...

Страница 15: ...battery fuses F 502 and F503 are located on the mains power supply printed board assembly 85272 behind the AMP battery connectors In case they need to be replaced commence as follows open the applianc...

Страница 16: ...that after reassembling wires running underneath the mains input printed board assembly 86243 are run with a minimum distance of at least 6 mm diagram 11 Printed board assembly 85272 showing the posi...

Страница 17: ...wer supply on battery operation operation voltage 24 V DC 10 30 battery operation UB V IB A Pi VA Pout W Pv W Standby 0idling Normal operation 10 dB Nominal conditions 24 24 24 24 0 06 1 1 7 5 18 1 5...

Страница 18: ...S 90208 input transformer per single input Order No 121 641 NRS 90227 monitor output transformer Order No 121 679 14 Specifications For DPA 4411 Accessories 14 1 NRS 90206 pilot tone surveillance for...

Отзывы: