Name
Input Routing
Parameters
F08
70V Single
In A > Out A&B Bridged Mode!
Hi-Pass 18dB @ 50Hz
C1800FDi
F08
70V Dual
In A > Out A
In B > Out B
Hi-Pass 18dB @ 50Hz
F09
70V Mono
In A > Out A
In A > Out B
Hi-Pass 18dB @ 50Hz
F10
100V Single
In A > Out A&B Bridged Mode!
Hi-Pass 18dB @ 50Hz
C2800FDi and C3600FDi
F08
70V Dual
In A > Out A
In B > Out B
Hi-Pass 18dB @ 50Hz
F09
70V Mono
In A > Out A
In A > Out B
Hi-Pass 18dB @ 50Hz
F10
100V Dual
In A > Out A
In B > Out B
Hi-Pass 18dB @ 50Hz
Table 7.3: C Series factory presets
Edit factory preset: When a factory preset is recalled and edited this is marked with an E.
Edited presets can be stored in one of the 50 User Presets.
Bridged configuration: If the amplifier is used in a bridged configuration, only channel A is
shown.
Preset: Is used to load or store a device preset. In addition to 10 factory presets there are also
50 user presets available.
AMP Setup: Is used to select between normal operation and bridged operation.
Notice!
Bridge operation requires different cabling.
Routing: Is used to select input signal routing for channels A and B: A, B, or A+B (sum).
DSP Edit:
EQ (Equalizer) for channel A & B: five band adjustable parameters are as shown in table.
Delay set the audio delay per channel A or B individually up to 650 ms. Units can be selected
in ms, meters, and feet in the Options.
GEQ this allows to bypass the Graphic EQ.
Notice!
The GEQ is only adjustable via remote control software.
LP/HP/Xover Freq: Factory presets with preset Hi-Pass/Lo-Pass or x-over frequencies is used
to modify the frequency parameter in the range of 30 Hz to 300 Hz.
Parameters: Select between channels A&B to be linked (all changes on CH A affect CH B) or
unlinked (changes on CH A do not affect CH B).
GPI Config (C Series only): Determines the two presets which can be toggled in-between
using the GPI contact.
Load Monitor: When signal is present the actual impedance per channel is displayed. Open
indicates that no speaker is connected. Shorted indicates a short circuit in the cabling. If the
signal is too low for a measurement it indicates Invalid.
L Series and C Series FIR-Drive Power
Amplifiers
Power amplifier menu navigation | en
27
Bosch Sicherheitssysteme GmbH
Installation manual
2017.10 | 02 | F.01U.327.801
Содержание C1300FDi-AU
Страница 1: ...L Series and C Series FIR Drive Power Amplifiers en Installation manual...
Страница 2: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......