Maintenance
Schedule
Daily
Every 30 Days
of use
Every 180
Days of use
Check Water Level
√
Remove sludge from
collection tank
√
Remove any
accumulated dust
√
Rinse mist traps with
clean water
√
Replace water in
collection tank
√
Inspect mist traps
√
Inspect V-Belt
√
Check Water Level:
Insure that water in main collection tank is at the proper height before beginning operation of machine.
Remove sludge from Collection Tank:
Sludge should be transported in a covered, vented steel container for storage or disposal in accordance with
federal, state and local regulations- sludge containing aluminum should be mixed with inert material (dry clay) in
the ratio 5 parts inert material to 1 part sludge.
Remove any accumulated dust:
Inspect the Metal Capture Station or Table exhaust vent, internal and external surfaces and surrounding work
area for any fugitive dust accumulation exceeding 1/32” thickness- remove with non-sparking, conductive
dustpans and natural bristle brushes.
Rinse Mist traps with clean water:
Remove mist traps from Metal Capture Station or Table and rinse with clean water to remove any trapped
sludge or debris. Once clean re-install mist traps before operation of machine.
Replace water in collection tank:
Replace the water in the collection tank with clean water-Dispose of used water in accordance with federal,
state and local regulations.
Inspect Mist Traps:
Inspect mist traps for signs of corrosion or damage. Replace if any corrosion or damage is found.
Inspect V-Belt:
Inspect V-Belt and replace if worn or damaged