![Dynabrade 64100 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/dynabrade/64100/64100_operating-manual_2546900006.webp)
W E T D E B U R R I N G S TAT I O N : O P E R AT I O N
6
OPERATION INSTRUCTIONS
1. Before operation starts, you must first make sure that the main tank
is at its proper water level in the “Power off” position. If water level is
low add water to the main tank or, operate your reservoir valve to the
fill position until desired level is reached as indicated on the label at
the front of the machine. Continue by then switching reservoir valve
to the “float” position.
2. Turn power switch on to start filtering action and begin work.
3. Check reservoir level every 8 hours and refill as necessary.
4. During operation, the float valve will transfer (Drip) water into the
main tank from the reservoir to make up for evaporation. Turn power
off after extended operation (Min 4 Hours) and re-check initial “Power
off” water level. If low, carefully bend the brass rod on the float
assembly to move float body up approximately 1/16". If "Power off"
water level is high, bend the brass rod on the float assembly to move
the float body down approximately 1/16". Re-check again after
extended operation.
(2)
POWER SWITCH
UPPER ACCESS PANEL
(Removal may be required to plug in accessory)
AUXILIARY
OUTLET 115V
ACCESSORY
CORD WRAP
(1)
WATER LEVEL WINDOW
(See set-up instructions for proper water level)
LEVEL HIGH BEND DOWNWARD
LEVEL LOW BEND UPWARD
(4)
ADJUSTING THE
FLOAT ARM MAY
BE REQUIRED TO
FINE TUNE WATER
TRANSFER FROM
RESERVOIR TO
MAIN TANK
(3)
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade