W E T   D E B U R R I N G   S TAT I O N :   O P E R AT I O N

6

OPERATION INSTRUCTIONS

1. Before operation starts, you must first make sure that the main tank

is at its proper water level in the “Power off” position. If water level is
low add water to the main tank or, operate your reservoir valve to the
fill position until desired level is reached as indicated on the label at
the front of the machine. Continue by then switching reservoir valve
to the “float” position.

2. Turn power switch on to start filtering action and begin work.

3. Check reservoir level every 8 hours and refill as necessary.

4. During operation, the float valve will transfer (Drip) water into the

main tank from the reservoir to make up for evaporation. Turn power
off after extended operation (Min 4 Hours) and re-check initial “Power
off” water level. If low, carefully bend the brass rod on the float
assembly to move float body up approximately 1/16". If "Power off"
water level is high, bend the brass rod on the float assembly to move
the float body down approximately 1/16". Re-check again after
extended operation.

(2) 

POWER SWITCH

UPPER ACCESS PANEL

(Removal may be required to plug in accessory)

AUXILIARY
OUTLET 115V

ACCESSORY
CORD WRAP

(1) 

WATER LEVEL WINDOW

(See set-up instructions for proper water level)

LEVEL HIGH BEND DOWNWARD

LEVEL LOW BEND UPWARD

(4) 

ADJUSTING THE
FLOAT ARM MAY
BE REQUIRED TO
FINE TUNE WATER
TRANSFER FROM
RESERVOIR TO
MAIN TANK

(3)

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Содержание 64100

Страница 1: ...PD06 31 IMPORTANT SAFETY INSTRUCTIONS SAFETY LEGEND Keep workplace area free of contaminants while deburring When operating this equipment basic precautions should always be strictly followed including the instructions listed below 21 Metalworking Station Operating Manual WARNING Read and understand tool manual before work starts to reduce risk of injury to operator visitors and tool WARNING Eye p...

Страница 2: ...t switch GFI POWER SUPPLY UPPER ACCESS PANEL DEBRIS SHIELD FILTER ACCESS PANEL REMOVABLE WORK SURFACE WATER LEVEL WINDOW CLEAN OUT VALVE FLOAT ASSEMBLY MAIN TANK RESERVOIR CONTROL VALVE RESERVOIR 2 Buy parts on line at https Dynashop co uk for all things Dynabrade Buy parts on line at https Dynashop co uk for all things Dynabrade ...

Страница 3: ...n 3 The next step is to add water to your station Fill the main acrylic tank A with water until you reach the line that indicates the proper level in the Power off position Continue by adding water to the reservoir B approximately 3 4 to the top 4 Switch reservoir valve to Float position 5 Plug in the 21 Metalworking Station Be sure to push the reset button on the GFI plug before turning system on...

Страница 4: ... Seal 46 64163 Seal 47 64120 Support Bracket 48 64147 Edge Trim 49 64149 Edge Trim 50 64150 Edge Trim 51 64152 Neoprene Strip 52 64153 Neoprene Strip 53 64154 Neoprene Strip 54 64155 Neoprene Strip 55 64156 Neoprene Strip 56 64157 Neoprene Strip 57 64158 Tubing 58 64160 Work Surface Assembly 59 64159 Tubing 60 64161 Tubing 61 64145 Seal 62 64162 Water Level Label 63 98598 Nut 64 64164 Locking Cam ...

Страница 5: ... 77 80 49 84 19 15 16 43 31 31 14 42 56 55 54 93 53 52 44 59 57 51 60 68 69 29 5 48 25 11 2 33 23 31 6 10 32 45 46 9 20 21 82 86 70 66 65 67 72 71 69 13 7 61 5 89 88 90 87 88 57 92 89 87 91 Buy parts on line at https Dynashop co uk for all things Dynabrade Buy parts on line at https Dynashop co uk for all things Dynabrade ...

Страница 6: ...oir to make up for evaporation Turn power off after extended operation Min 4 Hours and re check initial Power off water level If low carefully bend the brass rod on the float assembly to move float body up approximately 1 16 If Power off water level is high bend the brass rod on the float assembly to move the float body down approximately 1 16 Re check again after extended operation 2 POWER SWITCH...

Страница 7: ... to the main tank 4 Making sure clean out valve is in the OFF position remove the cap from the assembly The valve provided hooks up to a female garden hose for ease of clean out Turn valve lever to the ON position and drain tank Remove the sludge and remainder of water from the bottom of the tank making sure not to damage the acrylic tank while doing so When tank is clean turn valve back to the of...

Страница 8: ...00 344 1488 DYNABRADE EUROPE S à r l Zone Artisanale L 5485 Wormeldange Haut Luxembourg Phone 352 768 494 1 Fax 352 768 495 DYNABRADE DO BRASIL Rua Mário Fongaro 421 Vila Marlene São Bernardo do Campo SP CEP 09732 530 Telefax 11 4124 6040 MACHINE SPECIFICATIONS Model Weight Width Depth Height Number Voltage Phase Frequency Pound kg Inch mm Inch mm Inch mm 64100 120 1 60 Hz 110 50 21 533 20 508 36 ...

Отзывы: