1.0 INSPECTION
Carefully unpack and inspect your vacuum cleaner system for shipping damage.
Each vacuum cleaner system is tested and thoroughly inspected before being
shipped; therefore, any damage is the responsibility of the delivering carrier, who
should be notified.
2.0 APPLICATIONS
WARNING: A full Process Hazard Analysis has to be conducted by the user
for the recovery of dusts in hazardous locations. The
recommendations in this manual cannot, in any case, supplant
the conclusions of a full Process Hazard Analysis.
Model 61461 / EXP1-85 EX CFE HEPA is an explosion proof / dust ignition proof
vacuum cleaner system certified for use in Class I - Group D, T3C and Class II -
Groups E, F & G Hazardous Locations as defined in the NFPA 70 (National
Electrical Code and Canadian Electrical code).
Model 61461 / EXP1-85 EX CFE HEPA is designed for dry recovery only and for use
with vacuum assisted sanders and grinders. The dust is precipitated into an
immersion bath which neutralizes it.
WARNING:
It is the user’s responsibility to determine the appropriate
liquid to use to neutralize the dust.
WARNING:
This vacuum cleaner system is designed for the recovery of
dry materials only. Do not recover liquids.
WARNING:
Only tools and accessories provided by the manufacturer shall
be used with this vacuum cleaner system. The use of other
tools and accessories may impair safety.
Содержание 61461
Страница 15: ...Immersion separator a Detach the immersion separator...
Страница 16: ...b Remove the baffle system c Remove the sieve basket...
Страница 18: ...f Put back the sieve basket g Put back the baffle system in place...
Страница 25: ...Immersion separator a Clean the baffle system and remove all remaining material with brush...