Dynabrade 53811 Скачать руководство пользователя страница 2

2

SAFETY INSTRUCTIONS 

(Continued)

Accessory Selection:

• Abrasive/accessory RPM (speed) rating MUST be approved for AT LEAST the tool RPM rating.

• Before mounting an accessory, visually inspect for defects. Do not use defective accessories.

• Use only accessories of the correct shaft size for the collet (example: 1/4" shaft = 1/4" collet).

• Use only recommended accessories. Reference Dynabrade catalog and this tool manual.

• Follow tool specifications before choosing size and type of accessory.

• Only use recommended fittings and air line sizes. Air supply hoses and air hose accessories must have a minimum working pressure of 150 PSIG

(10 Bars) or 150 percent of the maximum pressure produced in the system, whichever is higher. (See tool Machine Specifications table.)

OPERATING INSTRUCTIONS

Warning: 

Always wear personal protective equipment. Operator of tool is responsible for following: accepted eye, face, respiratory, hearing and body protection.

Caution: 

Hand, wrist and arm injury may result from repetitive work, motion and overexposure to vibration.

• Keep hand and clothing away from working end of the air tool.

• Working end of tool has a potential of cutting and severing.

Operation: Be sure that any loose clothing, hair and all jewelry is properly restrained.

• Secure inlet bushing on air tool with a wrench before attempting to install the air fitting to avoid damaging housing assembly.

• BEFORE MOUNTING AN ACCESSORY, after all tool repairs and whenever a .7 hp Die Grinder is issued for use, check tool RPM (speed) with tachometer

with air pressure set at 90 PSIG while the tool is running. If tool is operating at a higher speed than the RPM marked on the tool housing, or operating
improperly, the tool must be serviced and corrected before use.

Caution: 

Tool RPM must never exceed abrasive/accessory RPM rating. Check accessory manufacturer for details on maximum operating speed or special

mounting instructions. Improper mounting of an accessory may cause excessive vibration levels or damage the accessory. Make sure no one is in the
unguarded plane of the accessory. Run tool for 1 minute of operating speed in a protected area.

• Connect air tool to power source. Be careful NOT to depress throttle lever in the process. 

Do not expose air tool to inlet pressure above 90 PSIG or (6.2 Bars).

Caution: 

After installing the accessory, before testing or use and/or after assembling tool, the .7 hp Die Grinder must be started at a reduced speed to check

for good balance. Gradually increase tool speed. DO NOT USE if tool vibration is excessive. Correct cause, and retest to insure safe operation. Test tool at
its free speed (RPM) in a protected area for at least one minute before applying the tool to the work. 

• Release throttle lever when air supply is interrupted.

• Make sure that work area is uncluttered, and visitors are at a safe range from the tools and debris.

• Air tools are not intended for use in explosive atmospheres and are not insulated for contact with electric power sources.

• Use a vise or clamping device to hold work piece firmly in place.

• Do not apply excessive force on tool or apply “rough” treatment to it.

• Always work with a firm footing, posture and proper lighting.

• Ensure that sparks and debris resulting from work does not create a hazard.

• Tool exhaust may contain lubricants, vane material, bearing grease, and other materials flushed thru the tool.

Warning: 

Grinding certain materials can create explosive dust. It is the employers responsibility to notify the user of acceptable dust levels.

• Grinding can cause sparks which can cause fires or explosions. It is the users responsibility to make sure the work area is free of flammable materials.

• DO NOT USE cut-off wheels or router bits on this tool.

• Always use dust extraction or suppression systems and personal protective equipment which are suitable for the materials being processed.

Report to your supervisor any condition of the tool, accessories, or operation you consider unsafe.

PROPER MOUNTING PROCEDURE

With Power Source Disconnected from the Tool, Mount Recommended Accessory

Collet Cap

Burr/Mounted Wheel

Collet Body

Mount Wheel/Burr Mandrel
Fully Inserted into Collet Insert.

Excessive Overhang Reduces Bit MOS,
Refer to ANSI B7.1 Standards

Содержание 53811

Страница 1: ...ng grinding drilling and other construction activities contain chemicals known to cause cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints...

Страница 2: ...sure no one is in the unguarded plane of the accessory Run tool for 1 minute of operating speed in a protected area Connect air tool to power source Be careful NOT to depress throttle lever in the pro...

Страница 3: ...g the tool and parts Do not clean tool or parts with any solvents or oils containing acids esters ketones chlorinated hydrocarbons or nitro carbons DO NOT clean or maintain tools with chemicals that h...

Страница 4: ...afety Lever 20 Housing Includes Bushing 01004 02391 Housing 53811 Includes 56022 Screen 02392 Housing 53812 21 01004 Bushing 22 01020 O Ring 23 01021 Valve Stem 24 01022 Spring 25 01023 Speed Regulato...

Страница 5: ...l the collet body onto the rotor Torque to 17 N m 150 in lbs 5 Check the clearance between the rotor and the bearing plate with a 001 03 mm thick feeler gauge The clearance should be 001 03 mm to 0015...

Страница 6: ...tite Corp Lifetime Warranty All Dynabrade portable pneumatic power tools are rigorously inspected and performance tested in our factory before shipping to our customers If a Dynabrade tool develops a...

Страница 7: ...1 X 14 01185 Vanes 4 Pkg 1 T 15 01028 Cylinder 1 X 16 See Note Rear Plate 1 X 17 02649 Bearing 1 T 18 01017 Pin 1 T 19 01089 Safety Lever 1 X 20 See Note Housing 1 X 21 01004 Bushing 1 X 22 01020 O R...

Страница 8: ...ools operating longer with greater power and less down time Part No 95842 1pt 473 ml Part No 95843 1gal 3 8 L Composite Style Coupler Lightweight 1 4 oz 05 Kg non marring composite material Easy conne...

Отзывы: