MAINTENANCE INSTRUCTIONS

Important:

To keep tool safe, a Preventative Maintenance Program is

recommended. The program should included inspection of the tool and all
related accessories and consumables, including air lines, pressure regulators,
filters, oilers, etc. refer to CAGI B186.1 for additional maintenance information.
If accessory or tool breakage occurs, investigate failure to determine the cause
and correct before issuing tool for work. Use the following schedule as a
starting point in developing a Preventative Maintenance Program. If tool does
not operate properly (RPM, Vibration, Start/Stop) after these scheduled
checks or at any time, the tool must be repaired and corrected before returning
tool to use.

INSTALLATION

• To ensure long life and dependable service, use a Closed Loop Air System

and Filter-Regulator-Lubricator as diagramed below.

• Each tool should have its own dedicated hose connected to an air supply

manifold. Quick disconnects should be installed at the manifold in an effort
to reduce contamination into the tool.

• It is strongly recommended that all Dynabrade rotary vane air tools be used

with a Filter-Regulator-Lubricator to minimize the possibility of misuse due
to unclean air, wet air or insufficient lubrication. Dynabrade recommends the
following: 

10681

Air Line Filter-Regulator-Lubricator — Provides accurate

air pressure regulation, two-stage filtration of water contaminants and
micro-mist lubrication of pneumatic components.

• Dynabrade recommends one drop of air lube per minute for each 20 SCFM

(example: if the tool specification states 40 SCFM, set the drip rate on the
filter-lubricator to 2 drops per minute) Dynabrade Air Lube (P/N 

95842

:

1pt/473ml) is recommended.

MAINTENANCE SCHEDULE

Daily (every 8 hours):

• Inspect tool and accessories for damage or broken parts. Replace items 

as necessary to ensure proper operation and safety.

• Lubricate motor as recommended. Use Dynabrade Air Lube (P/N 

95842

:

1pt/473ml) 10W/NR. (1 Drop per minute of air lube per 20 SCFM.)

• Check air line pressure with a gage. (MAX. 90 PSIG or 6.2 Bar operating

pressure at the air inlet of the tool.)

• Right angled gear and wick system through gear case grease fitting with 

3 plunges of gear oil (P/N 

95848

) and grease gun (P/N 

95541

). (Prime

grease gun prior to greasing.)

• Check tool for proper operation: If operating improperly or demonstrates

unusual vibration, the tool must be serviced and problem corrected before
further use.

Every 20 Hours or Once a Week Which Ever Comes First:

• Check free speed of tool without the abrasive accessory mounted.  Measure

RPM (speed) with tachometer and with air pressure set at 90 PSIG while the
tool is running. If a governed tool is operating at a higher speed than the
RPM marked on the tool housing, the tool must be serviced and corrected
before use. A non-governed tool may exceed the RPM marked on the tool
by 10% when operated at free speed with no accessories.

• If tool is running fast look for worn, damaged or missing governors, air

control rings and silencers. Special care must be taken when servicing

governors and speed control devices. Injection molded governor assemblies
are non-serviceable and must be replaced.  

• If tool is running slow look for clogged inlet screen, air stream, silencer(s)

or a malfunctioning governor (see concerns for servicing governors).
Service as required. 

Every 50 Hours:

• Lubricate planetary gears through gear case grease fitting with 3 plunges

of grease (P/N 

95542

) and grease gun (P/N 

95541

). (Prime grease gun

prior to greasing.)

REPAIR

• Use only genuine Dynabrade replacement parts to ensure quality. To order

replacement parts, specify Model#, Serial# and RPM of your air tool.

• Mineral spirits are recommended when cleaning the tool and parts. Do 

not clean tool or parts with any solvents or oils containing acids, esters,
ketones, chlorinated hydrocarbons or nitro carbons.

• DO NOT clean or maintain tools with chemicals that have a low flash point

(example: WD-40

®

).

• Motor Tune-Up Kit are available (when applicable) which includes high wear

and medium wear motor parts.

• Air tool markings must be kept legible at all times, if not, reorder housing

and replace. User is responsible for maintaining specification information.

• After maintenance is performed on tool, add a few drops of Dynabrade 

Air Lube (P/N 

95842

) to the tool inlet and start the tool a few times 

to lubricate air motor. Verify RPM (per 20 hr maintenance schedule),
vibration and operation.

HANDLING & STORAGE

• Use of tool rests, hangers and/or balancers is recommended.

• Protect tool inlet from debris (see Notice).

• DO NOT carry tool by air hose or near the tool throttle lever.

• Store accessories in protective racks or compartments to prevent damage.

• Follow the handling instructions outlined in the operating instructions when

carrying the tool and when changing accessories.

• Protect accessories from exposure to water, solvents, high humidity,

freezing temperature and extreme temperature changes.

END OF USE / DISPOSAL

When tool has reached its end of useful service, disassemble tool into its
primary components (i.e. steel, aluminum and plastic part) and recycle or discard
per local, state and/or federal regulations as to not harm the environment.

NOTICE

All Dynabrade motors use the highest quality parts and metals available and
are machined to exacting tolerances. The failure of quality pneumatic  motors
can most often be traced to an unclean air supply or the lack of lubrication. 
Air pressure easily forces dirt or water contained in the air supply into motor
bearings causing early failure. It often scores the cylinder walls and the rotor
blades resulting in limited efficiency and power. Our warranty obligation is
contingent upon proper use of our tools and  cannot apply to equipment 
which has been subjected to misuse such as unclean air, wet air or a lack 
of lubrication during the use of this tool.

2

Filter

Regulator

Lubricator

90 PSIG

(6.2 Bar)

To Tool Station

Ball

Valve

Ball

Valve

Filter

Regulator

Lubricator

Air Flow

Drain
Valve

Drain
Valve

Air Tool

Air Compressor

and Receiver

Drain Valve

Air Hose

90 PSIG MAX

(6.2 Bar)

Air Flow

Refrigerated

Air Dryer

1

DROP/MIN.

20

SCFM

LUBRICATOR SETTING

• Dynabrade Air Power Tools are designed to operate at 90 PSIG 

(6.2 Bar) maximum air pressure at the tool inlet, when the tool is
running. Use recommended regulator to control air pressure.

• Ideally the air supply should be free from moisture. To facilitate

removing moisture from air supply, the installation of a refrigerated 
air dryer after the compressor and the use of drain valves at each 
tool station is recommended.

AIR SYSTEM

Closed Loop Pipe System, Sloped in Direction of Air Flow

Содержание 48520

Страница 1: ... these chemicals are Lead from lead based paints Crystalline silica from bricks and cement and other masonry products Arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that ...

Страница 2: ... inlet screen air stream silencer s or a malfunctioning governor see concerns for servicing governors Service as required Every 50 Hours Lubricate planetary gears through gear case grease fitting with 3 plunges of grease P N 95542 and grease gun P N 95541 Prime grease gun prior to greasing REPAIR Use only genuine Dynabrade replacement parts to ensure quality To order replacement parts specify Mode...

Страница 3: ... 1 13 45272 GOVERNOR ASSEMBLY 1 14 45320 GOVERNOR CHAMBER 1 15 45307 HOUSING ASSEMBLY 1 16 96077 O RING 1 17 SLEEVE See Chart Page 4 1 18 97060 PIN 1 19 45315 BUSHING 1 20 97045 PIN 1 21 45263 THROTTLE LEVER 1 22 45310 SEAL 1 23 58365 TIP VALVE 1 24 01468 SPRING 1 25 01564 AIR CONTROL RING 1 26 94535 STANDARD MUFFLER ASSEMBLY 1 26 1 95711 SNAP RING 1 26 2 01486 FELT SILENCER 4 26 3 96065 O RING 1 ...

Страница 4: ...M 4 hp 298 W 78 db A 25 SCFM 708 LPM 90 PSIG 6 2 Bars 1 4 lb 0 63 kg 8 203 mm 3 5 89 mm 48531 15 000 RPM 4 hp 298 W 79 db A 25 SCFM 708 LPM 90 PSIG 6 2 Bars 1 4 lb 0 63 kg 8 203 mm 3 5 89 mm 48532 20 000 RPM 4 hp 298 W 78 db A 25 SCFM 708 LPM 90 PSIG 6 2 Bars 1 4 lb 0 63 kg 8 203 mm 3 5 89 mm 48540 12 000 RPM 4 hp 298 W 81 db A 25 SCFM 708 LPM 90 PSIG 6 2 Bars 1 1 lb 0 5 kg 6 5 164 mm 3 5 89 mm 48...