Dynabrade 40352 Скачать руководство пользователя страница 7

7.

Fasten the rotor in the vise with aluminum or bronze jaws so that the 

04117 

Adapter is

pointing up.

Use the 

96076, 

12 mm, or an adjustable wrench to remove the 

04117 

Adapter. Turn

counterclockwise.
Remove the bearing, plate, shims and the 

01479 

Spacer.

Motor Disassembly Complete.

Clean and inspect parts before assembling.

12 mm

Отзывы: