Dynabrade 10671 Скачать руководство пользователя страница 3

Filter - 10671

Regulator - 10673

Lubricator - 10675

Standard Specifications

Port Size:

1/2"

Fluid:

Air

Proof Pressure:

218 PSIG (15 Bar)

Maximum Operating Pressure:

145 PSIG (10 Bar)

Ambient and Fluid Temperature:

23 to 140˚F (-5 to 60˚C) [with no freezing]

Normal Filtration Rating:

5µm

Bowl Material:

Polycarbonate

Bowl Guard:

Standard

Drain Capacity oz (cm

3

):

1.58 (45)

Weight lb (kg):

0.99 (0.49)

Standard Specifications

Port Size:

1/2"

Fluid:

Air

Proof Pressure:

218 PSIG (15 Bar)

Maximum Operating Pressure:

7 to 123 PSIG (8.5 Bar)

Pressure Gauge Port Size:

Rc, NPT, G1/4

Relief Pressure:

Set Pr7 PSIG (.5 Bar)

Ambient and Fluid Temperature:

23 to 140˚F (-5 to 60˚C) [with no freezing]

Construction:

Relieving Type

Weight lb (kg):

0.97 (0.44)

Flow Characteristics

(Representative values)

Flow Characteristics

(Representative values)

Condition: Inlet pressure 102 PSIG

Pressure Characteristics

(Representative values)

Condition: Inlet pressure 102 PSIG

Outlet pressure 29 PSIG
Flow rate .7 SCFM

Standard Specifications

Port Size:

1/2"

Fluid:

Air

Proof Pressure:

218 PSIG (15 Bars)

Maximum Operating Pressure:

145 PSIG (10 Bars)

Minimum Dripping Flow Rate [L/min (ANR)]:

1/2: 50

Oil Capacity oz (cm

3

):

4.6 (135)

Recommended Lubricant:

Class 1 turbine oil (ISO VG32)

Ambient and Fluid Temperature:

23 to 140˚F (-5 to 60˚C)

[with no freezing]

Bowl Material:

Polycarbonate

Bowl Guard:

Standard

Weight lb (kg):

1.04 (0.47)

Flow Characteristics

(Representative values)

Condition: Inlet pressure 102 PSIG

3

These specifications are applicable if the 3/8" reducer bushings are used.

These specifications are applicable if the 3/8" reducer bushings are used.

These specifications are applicable if the 3/8" reducer bushings are used.

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Содержание 10671

Страница 1: ...applicable safety codes and regulations Please refer to Dynabrade s Warning Safety Operating Instructions for more complete safety information Inlet Outlet Port Size Max Air Pressure Max Air Flow Max...

Страница 2: ...valve allows oil to be added to the Lubricator oil reservoir bowl without shutting off the air supply and interruption to work operations 2 Remove the fill black cap plug by turning it counterclockwi...

Страница 3: ...es Condition Inlet pressure 102 PSIG Pressure Characteristics Representative values Condition Inlet pressure 102 PSIG Outlet pressure 29 PSIG Flow rate 7 SCFM Standard Specifications Port Size 1 2 Flu...

Страница 4: ...Understanding JIS B 8370 General Rules for Pneumatic Equipment and other safety rules are included 3 Do not service the machinery equipment or attempt to remove components until safety is confirmed 1...

Страница 5: ...ressure release i e residual pressure may or may not be released depending on the operating conditions b Contact Dynabrade if air will not be consumed in the system for a long period of time or if the...

Страница 6: ...ection that increases pressure and lock the knob after the pressure is set If this is done in the direction that decreases pressure the pressure may drop from the original set pressure Turning the kno...

Страница 7: ...to the element b Release accumulated condensate periodically before it reaches the maximum capacity Condensate that flows out to the outlet side can cause malfunctions Caution 1 Perform periodical in...

Страница 8: ...M Pressure Drop Across FRL PSIG Bar 15 425 2 0 14 30 850 3 0 21 45 1274 6 0 41 60 1699 7 0 48 75 2124 8 0 55 Regulator Lubricator Unit has modular connections with mounting brackets for easy installat...