Dynablast BEF series Скачать руководство пользователя страница 5

SETTING UP (CONTINUED)

ADJUSTING THE BURNER

Allow sufficient air to obtain a clean looking flame by loosening the lock screws and moving the air shutter, and if 

necessary, the bulk air band. Reduce the air supply until the flame tips appear slightly smoky, then increase the 

air just enough to cause the flame tips to appear absolutely clean. 

DRAFT CONTROL ADJUSTMENTS

The unit is set up in the factory to burn cleanly into atmospheric conditions. Therefore if a chimney is fitted to the 

machine, an  "O" draft would be the optimum condition.

FINAL AIR-ADJUSTMENTS

Allow at least ten minutes for warm-up, and longer if the unit is new, in order to burn off the oil deposits on the 

heat exchanger and other surfaces. Check and adjust all controls. (See Manufacturer’s Instructions sheets.) Test 

the primary control Safety Switch to insure a safety shutdown will occur in the event of equipment malfunction

NOTE

 - These settings have already been completed for the machine and only apply if a new burner or coil is 

installed.

OPERATION

STARTING THE MACHINE

1.   Make sure all switches are in the "OFF" position.

2.   Connect the electrical supply cable. (Plug the unit into the electrical receptacle.)

3.   In "SETTING UP INSTRUCTIONS" you have already been asked to connect the unit to the water supply. 

Turn on the water.

4.   Pick up the spray gun and hold it firmly, and pull the trigger to evacuate all air in the system. Release gun 

trigger.

5.   Now turn Pump Switch to "ON". The pumping unit will start.

6.   Hold the spray gun firmly and squeeze the trigger on the gun, and when the spray is constant, turn the 

Burner Switch to "ON". The oil burner will ignite. Then turn "THERMOSTAT" to the desired temperature.

 

CAUTION

 - The force of the water leaving the nozzle causes a kickback or recoil at the trigger gun.

3

BEF 

SERIES

Содержание BEF series

Страница 1: ...OPERATOR S MANUAL HOT WATER PRESSURE WASHERS SERIES Dynablast Inc 2625 Meadowpine Blvd Mississauga Ontario L5N 7K5 Canada 1 877 52BLAST 25278 www dynablast com MAN BEF BEF...

Страница 2: ...S WITH FLOAT BOX AND SOAP INDUCTION UNIT 5 THINGS TO CHECK REGULARLY 5 WINTERIZING YOUR PRESSURE WASHER 6 SERVICE AND MAINTENANCE 6 ANNUAL BURNER SERVICE 7 INDOOR INSTALLATION 8 SPECIFICATIONS AND FEA...

Страница 3: ...ngerous 10 KEEP CHILDREN AWAY from the machine and wash area 11 VENTILATE work area when using toxic or pungent additives to reduce your exposure to the noxious fumes 12 Use PROTECTIVE WEAR especially...

Страница 4: ...30W non detergent heavy duty oil You can also use the dipstick part of the cap to check the oil level Also ensure that the vent hole in the cap dipstick is clear of dirt BURNER FUEL Fill the burner f...

Страница 5: ...mary control Safety Switch to insure a safety shutdown will occur in the event of equipment malfunction NOTE These settings have already been completed for the machine and only apply if a new burner o...

Страница 6: ...p closing the reed contact This contact is interlocked with the fuel solenoid valve in the oil pump UNLOADER The unloader allows all of the water delivered by the pump to return to the pump suction si...

Страница 7: ...ened stainless steel nozzles supplied may wear and give reduced pressure Be sure to replace with the same size or order from the dealer THINGS TO CHECK REGULARLY 1 Check for SYSTEM LEAKS Leaks in the...

Страница 8: ...tifreeze into bypass line Shut off motor unit is now winterized CAUTION If your hose is longer than 35 feet the float box may empty before the liquid from the nozzle gets foamy If this happens refill...

Страница 9: ...s over 50 psi descaling is recommended Descaling requires the use of highly corrosive chemicals It also requires the use of goggles and special protective clothing 1 This procedure requires a 20L pail...

Страница 10: ...hese hot water pressure cleaners burn No 1 or No 2 Fuel Oil This means that air is required for combustion and for ventilation The appliance installer will know how and where to place a supply air duc...

Страница 11: ...el Type No 1 or No 2 No 1 or No 2 No 1 or No 2 Fuel Oil Fuel Oil Fuel Oil STANDARD Unloader Standard Standard Standard SAFETY Pressure Switch COMPONENTS High Temp Limit Protector Pressure Relief Valve...

Страница 12: ...t orifice restricted Remove orifice at tip of gun and clean Flush coil with water before replacing Scale or dirt in coils De scale coils Pump speed too high Check water output GPM Relief Valve Operate...

Страница 13: ...Electrode insulator failure Check for breaks cracks or spark trails Replace Water flow switch not closing Adjust repair or replace Fuel solenoid valve not opening Clean repair or replace Weak transfo...

Страница 14: ...Latest update 22 03 2005 60 1280 00 VB8 unload 3 8F Bsp 60 1290 00 VB8 unload 3 8F Bsp...

Страница 15: ...housing 1 5 18 16 2100 00 M 4 x 4 mm dowel 1 25 19 60 1704 31 M 22 nut 1 5 20 14 3719 00 Washer 9 x 15 mm 1 10 21 60 1208 61 3 2 x 33 mm spring 1 5 22 60 1210 31 Upper frame 1 10 23 14 7421 00 1 4 bal...

Страница 16: ...ELECTRICAL WIRING DIAGRAM 1 PHASE 12 BEF SERIES...

Страница 17: ...ELECTRICAL WIRING DIAGRAM 3 PHASE 13 BEF SERIES...

Страница 18: ...lacement of parts and is given to the purchaser in lieu of all other remedies including incidental and consequential charges There are no expressed warranties other than those specified herein SPECIAL...

Страница 19: ...in its recommendations However the ultimate responsibility for product application decisions shall rest with the customer The sole and only warranty made by Dynablast Inc is the limited warranty desc...

Отзывы: