background image

Page 9

60707-101

DYNA SERIES

OPERATOR CARE AND MAINTENANCE

Содержание DLC4500

Страница 1: ...INSTALLATION OPERATION and MAINTENANCE INSTRUCTIONS PORTABLE GENERATORS DLC SERIES TFLC SERIES LLC SERIES LC SERIES ...

Страница 2: ...roperlymaintained COPY YOUR MODEL AND SERIAL NUMBER HERE No other DYNA generator has the same serial number as yours It is important that you record the number and other vital information here If you should ever need to contact us on this unit it will help us to respond to your needsfaster MODEL______________________________________ SERIALNUMBER_____________________________ PURCHASEDATE___________...

Страница 3: ...YES YES 4 5 GAL NO YES YES NO NO YES LLC5000H HONDA YES NO 4 5 GAL NO YES NO NO NO YES LLC6000 B S STD YES NO 4 5 GAL NO YES NO NO NO YES LLC6000H HONDA YES NO 4 5 GAL NO YES NO NO NO NO LLC6000HE HONDA YES NO 4 5 GAL NO YES YES NO NO NO LLC9000E B S VGD YES YES 4 5 GAL NO YES YES NO NO NO LLC9500HE HONDA YES YES 4 5 GAL NO YES YES NO NO NO LLC15000KE KOHLER YES YES 4 5 GAL NO YES YES NO NO NO DLC...

Страница 4: ...of children c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel only in an approved container and only in a well ventilated area GUIDE TO PRODUCT SAFETY 3 DEADLY EXHAUST GAS Exhaust fumes from any gasoline engine contain carbon monoxide an invisible odorless ...

Страница 5: ...n bring the motor up to speed in a few seconds of time If difficulty is experienced in starting motors turn all other electrical loads off and if possible reduce the load on the electric motor UNPACKING CAUTION EQUIPMENTDAMAGE THIS UNIT HAS BEEN SHIPPED WITHOUT OIL Failure to maintain the engine oil at the proper level will result in serious engine damage These portable units require large quantit...

Страница 6: ...battery voltage will immediately increase about 0 5 volts showing that the battery is being When you unpack your new ENGINE GENERATOR be sure to remove all the information sheets and manuals from the carton 1 This power plant was in good order when shipped Inspect the power plant promptly after receiving it If damage is noted notify the transportation company immediately request proper procedures ...

Страница 7: ...vernor but neither does it correct them The automatic idle control consists of a solid state module switch resistor and a transformer located in the generator control box and an electromagnet mounted on the engine near the throttle lever The automatic idle control is only offered as a factory installed feature It is not available for field installation With the automatic idle switch in the automat...

Страница 8: ...uency CAUTION EQUIPMENT DAMAGE The output voltage should be checked to insure the generator is working properly prior to connecting a load to the generator Failure to do so could result in damage to equipment plugged into the unit and possible injury to the individual All engines have a tendency to slow down when a load is applied When the electrical load is connected to the generator the engine i...

Страница 9: ...alk Many homes today are wired for at least 60 to 100 Amp entrance service much greater than the capacity of these portable generators Do not attempt to power a home with this portable generator This generator set is suitable for powering individual appliances or emergency lighting ENGINE CARE If major engine service or repair is required contact an authorized engine service center The manufacture...

Страница 10: ...ce for the operator To disable the OILGARD remove the wire attached to the sensor unit mounted on the engine crankcase The wire should be insulated with a connector or tape Honda powered generators These engine generator sets come equipped standard with the Honda Oil Alert System The Oil Alert system is designed to prevent damage caused by an insufficient amount of oil in the crankcase Before the ...

Страница 11: ...Page 9 60707 101 DYNA SERIES OPERATOR CARE AND MAINTENANCE ...

Страница 12: ...prior to placing the unit in service The user shall assume all risks and liability in connection with determining the suitability of the unit for its particular use Neither the manufacturer nor the seller shall be liable for any injury loss or damage arising out of improper use or operation of this unit In no event is WINCO liable for incidental or consequential damages Some states do not allow li...

Отзывы: