WINCO warrants to the original purchaser that the alternator is free from defects in workmanship and material for a period of
two years*,  provided it is installed, operated and maintained in accordance with WINCO written instructions.

*NOTE:  Units used for rental, demonstrations, commercial or prime power applications such as construction or utility,
are warranted for 90 days.  Units that are resold are not covered under this warranty. Any further warranty, whether
expressed or implied, rests solely with the reseller.

WINCO’s  sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the
product.  At WINCO’s  option, material found to be defective in material or workmanship under normal use and service will be
repaired or replaced.  This warranty does not include circuit breakers, receptacles or ENGINES.  Engines are covered
exclusively by the warranties of their respective manufacturers.

THERE IS NO OTHER EXPRESS WARRANTY.

To the extent permitted by law, any and all warranties are limited to 24 months from date of purchase.  The user shall
determine the suitability of the product for its intended use prior to placing the unit in service.  The user shall assume all
risks and liability in connection with determining the suitability of the unit for its particular use.  Neither the manufacturer nor
the seller shall be liable for any injury, loss or damage arising out of improper use or operation of this unit. In no event is
WINCO  liable for incidental or consequential damages.

Some states do not allow limitation on the duration of implied warranty and some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitations may not apply in every instance.  This warranty
gives you specific legal rights which may vary state to state.

WINCO reserves the right to change or improve its products without incurring any obligations to make such changes or
improvements on products previously purchased.

WINCO does not warrant products which have been subjected to misuse, negligence, modified or altered in any way or have
been involved in an accident.

For warranty service, return the product, transportation charges prepaid, to your nearest WINCO Authorized Service Center or
to  WINCO at Le Center Minnesota.  When requesting warranty service, evidence of original purchase date must be
presented.

24 MONTH

Limited Warranty

DYNA SERIES 5/97

P/N 60707-110

Phone

-

(507) 357-6831

FAX -

(507) 357-4857

225 S. Cordova Ave.
LeCenter, Mn  56057-1805

Содержание D3000

Страница 1: ...INSTALLATION OPERATION and MAINTENANCE INSTRUCTIONS PORTABLE GENERATORS D3000 DL9000E DL5000H ...

Страница 2: ...RE No other DYNA generator has the same serial number as yours It is important that you record the number and other vital information here If you should ever need to contact us on this unit it will help us to respond to your needsfaster MODEL______________________________________ SERIALNUMBER_____________________________ PURCHASEDATE_____________________________ DEALER_____________________________...

Страница 3: ... D5500 B S GEN PRO NO NO 6 QT NO YES NO NO DL4500 B S STD YES NO 4 5 GAL NO YES NO NO DL4500E B S STD YES YES 4 5 GAL NO YES YES NO DL5000H HONDA YES NO 4 5 GAL NO YES NO NO DL6000 B S STD YES NO 4 5 GAL NO YES NO NO DL6000E B S STD YES YES 4 5 GAL NO YES YES NO DL6000H HONDA YES NO 4 5 GAL NO YES NO NO DL6000HE HONDA YES YES 4 5 GAL NO YES YES NO DL9000E B S VGD YES YES 4 5 GAL NO YES YES NO DL60...

Страница 4: ...d other fuels always present a hazard of possible explosion and or fire a Do not refuel when the engine is running or hot Allow the engine to cool at least two minutes before refueling b Keep fuel containers out of reach of children c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are...

Страница 5: ...l burn out in a short time The generator winding might also be damaged CAUTION EQUIPMENTDAMAGE RUNNING THE GENERATOR SET UNDER THESE CONDITIONS MAY RESULT IN DAMAGING THE GENERATOR STATOR AS WELL AS THE MOTOR WINDING Because the heavy surge of current required for starting motors is required for only an instant the generator will not be damaged if it can bring the motor up to speed in a few second...

Страница 6: ...egative battery leads are accidentally shorted or are incorrectly connected to the battery the automatic resetting DC circuit breaker in the control panel will trip to protect the generator and the battery This breaker will reset automatically restoring the voltage UNPACKING CAUTION EQUIPMENTDAMAGE THIS UNIT HAS BEEN SHIPPED WITHOUT OIL Failure to maintain the engine oil at the proper level will r...

Страница 7: ...er OPERATING LOCATION The engine generator models covered in this manual were designed for portable use DO NOT INSTALL OR OPERATE THESE UNITS INDOORS The unit should be stored in a dry location During a power outage move the unit outdoors to a flat dry location such as a driveway concrete pad or sidewalk for use We recommend installing the optional dolly kit or equivalent for ease of handling The ...

Страница 8: ...ze This is the reason for the larger tanks at low temperature Minimum sizing is not based on running time BASIC OPERATION Temp 60 deg f 30 deg f 0 deg f 20 deg f DL6000TFE 40 gal 50 gal 125 gal 350 gal DL9000TFE 70 gal 80 gal 200 gal 700 gal CHANGINGFUELTYPES These engine generator sets are designed to run on three different fuels gasoline natural gas or LP vapor They may be easily changed from on...

Страница 9: ... each minute Repeat if necessary 4 When the engine starts open the choke gradually 5 The engine should promptly come up to operating speed CAUTION EQUIPMENTDAMAGE Never permit the choke to remain on after the engine has run for a short time It is not necessary to choke the engine when it is warm Avoid over choking STARTING HINTS 1 Cold weather a Use the proper oil for the temperature expected b Us...

Страница 10: ...LOAD Keep the generator load within the generator and receptacle nameplate rating Overloading may cause damage to the generator and or the loads Most electric tools and appliances will have the voltage and amperage requirements on their individual nameplates When in doubt consult the manufacturer or a local electrician The nameplate amperage rating for electric motors can be misleading See Startin...

Страница 11: ...the unit up and to dry out any moisture that has accumulated in the windings If left this moisture can cause corrosion in the winding Frequent operation of the engine generator set will also insure that the set is operating properly should it be needed in an emergency 2 Generator Maintenance Any major generator service including the installation or replacement of parts should be performed only by ...

Страница 12: ... placing the unit in service The user shall assume all risks and liability in connection with determining the suitability of the unit for its particular use Neither the manufacturer nor the seller shall be liable for any injury loss or damage arising out of improper use or operation of this unit In no event is WINCO liable for incidental or consequential damages Some states do not allow limitation...

Отзывы: