Dyna-Glo RA100NGDGD Скачать руководство пользователя страница 9

Figure 7 – Repair Parts Illustration for Natural Gas Radiant Heater RA250NGDGD

9

E

N
G

L

I

S

H

E

N
G

L

I

S

H

RA250NGDGD

Dyna-Glo Delux Operating Instructions and Parts Manual

1

2

3

7

8

9

6

10

11

12
13

14

15

16

17

18

19

20

4

5

21

22

23

24

25

26

27

28

29

30

31

33

32

34

35

36

37

38

39

40

41

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:00 am - 5:00 pm CST          www.ghpgroupinc.com

For repair Parts, call 1-877-447-4768

Please provide following information:

-Model number

-Serial number (if any)

-Part description and number as shown in parts list

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Содержание RA100NGDGD

Страница 1: ...s heater If you need assistance or heater information such as an instruction manual labels etc contact your local manufacturer Consumer Retain this manual for future reference Dyna Glo Delux Natural G...

Страница 2: ...ntenance method you use Carbon Monoxide poisoning may lead to death Some people are more affected by Carbon Monoxide than others Early signs of carbon monoxide poisoning resemble the flu with headache...

Страница 3: ...ious or fatal injury Assembly MODEL RA100NGDGD 1 Provide natural gas supply system 2 Install plumbing to a low pressure natural gas source to heater The source must be regulated to 1 2 PSI maximum 3 4...

Страница 4: ...o the OFF position 2 Firmly close the natural gas supply valve TO RESTART HEATER 1 Wait five minutes for heater to cool 2 Follow steps in TO START HEATER section TO START HEATER RA250NGDGD 1 Follow al...

Страница 5: ...k NFPA54 ANSI Z223 1 or the Natural Gas Installation Code CAN CSA B149 1 VENTILATION A three square foot opening of fresh outside air for each 100 000 BTU Hr of heater output must be provided to opera...

Страница 6: ...0NGDGD Dyna Glo Delux Operating Instructions and Parts Manual Symptom Possible Cause s Corrective Action Burner fails to light Burner lights but goes out when automatic control valve button is release...

Страница 7: ...ll 1 877 447 4768 Please provide following information Model number Serial number if any Part description and number as shown in parts list Figure 6 Repair Parts Illustration for Natural Gas Radiant H...

Страница 8: ...Base 5002851 1 14 Control Knob 2101451 1 15 Control Valve 5050651 1 16 Fitting 2304948 2 17 Tubing Inlet Assy 2315524 1 18 Fitting Regulator to Tubing Inlet 2315547 1 19 Regulator 2315555 1 20 Regula...

Страница 9: ...3 14 15 16 17 18 19 20 4 5 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 38 39 40 41 For Technical Support or Troubleshooting Call 1 877 447 4768 8 00 am 5 00 pm CST www ghpgroupinc com For Repai...

Страница 10: ...5536 1 25 Regulator Connector 2315547 1 26 Inlet Tubing Assy 2315542 1 27 Connector 2315549 1 28 Control Valve 5001423 1 29 Contol Valve Fixing Nut 2305687 1 30 Contol Valve Bracket 2315538 1 31 Ball...

Страница 11: ...MAGES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or cons...

Страница 12: ...u can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here Tel...

Отзывы: