11.  TROUBLESHOOTING GUIDE

TROUBLE

POSSIBLE CAUSE

CORRECTIVE ACTION

Heater ignites but MAIN PCB 

assembly shuts heater off after a 

short period of time. 

(Indicator Lamp is flickering and 

room temp. display indicates “ E1 “)

1.  Wrong pump pressure.

2.  Dirty Air Output,Air Intake  

  or Lint Filter. 

3.  Dirty Fuel Filter. 

4.  Dirt in Nozzle.

5.  Dirty Photocell Lens.

6.  Photocell Assembly not 

  Properly installed.(Not seeing the 

  flame)

7.  Bad electrical connection 

  between photocell and MAIN PCB 

  assembly. 

8.  Defective Photocell.

1.  See Pump Pressure Adjustment, 

  Page 13.

2.  See Air Output, Air intake

  and Lint Filters, page 10.

3.  See Fuel Filter, Page 13.

4.  See Nozzle, Page 11.

5.  Clean Photocell Lens, Page 12.

6.  Make sure photocell boot is

  properly seated in bracket,

  Page 12.

7.  Check electrical components

  See wiring diagram, Page 16.

8.  Replace Photocell, Page 12.

Heater will not ignite but motor 

runs for a short period

of time.(Indicator Lamp is flickering 

and room temp.display

indicates “ E1 “)

1.  No fuel in tank.

2.  Wrong pump pressure.

3.  Carbon deposits on spark plug and/

  or improper gap.

4.  Dirty fuel filter.

5.  Dirt in Nozzle.

6.  Water in fuel tank.

7.  Bad electrical connection between 

  ignitor and MAIN PCB assembly.

8.  Ignition wire is not attached to 

  spark plug.

1.  Fill tank with kerosene.

2.  See Pump Pressure Adjustment, 

  Page 13.

3.  See Spark Plug, Page 12.

4.  See Fuel Filter, Page 13.

5.  See Nozzle, Page 11.

6.  Flush fuel tank with clean 

  kerosene, Page 9.

7.  Check electrical components

  See wiring diagram, Page 16.

8.  Attach ignition wire to spark plug. 

  See Spark Plug, Page 12.

Fan does not turn when heater is 

plugged in and power switch was in 

the “ ON “ Position.

(Indicator Lamp is on or flickering)

1.  Thermostat setting is too low.

2.  Bad electrical connection between 

  motor and MAIN PCB assembly.

1.  Turn thermostat control knob to a 

  higher setting.

2.  Check electrical connections, See 

  Wiring Diagram, Page 16.

(Indicator Lamp is flickering and 

room temp. display indicates “E2”)

1.  Sensor Failure.

1.  Replace sensor.

  See Wiring diagram, Page 16.

(Indicator Lamp is flickering and 

room temp. display indicates “E3”)

1.  Thermostat switch failure.

1.  Replace switch.

  See Wiring diagram, Page 16.

Heater will not turn-on

(Indicator Lamp is off)

1.  Temperature limit safety device is  

  overheated.

2.  No electrical power

3.  Blown fuse.

4.  Bad electrical connection between  

  temperature limit safety device and 

  PCB board.

1.  Turn power switch to “OFF”

  and allow to cool (about 10 min.)

2.  Check to insure heater cord and  

  extension cord are plugged in.  

  Check power supply.

3.  Replace safety fuse in PCB board.

4.  Check electrical connections

  See Wiring Diagram, Page 16.

NEVER LEAVE THE HEATER 

UNATTENDED WHILE BURNING!

Содержание KFA135H

Страница 1: ...r manner in which to assemble maintain store and most importantly how to operate the heater in a safe and efficient manner Please keep this manual for future reference COMPLIES WITH UL733 AND ANSI A10...

Страница 2: ...of heater NEVER use duct work in front or behind of heater NEVER move handle service a hot operating or plugged in heater NEVER transport heater with fuel in it s tank When used with an optional therm...

Страница 3: ...23 1 INTRODUCTION Please read this USER S MANUAL carefully It will show you how to assemble maintain and operate the heater safely and efficiently to obtain full benefits from its many built in featur...

Страница 4: ...ell Hot Air Outlet Shell Lower Fuel Gauge Fuel Cap Side Cover Lamp Thermostat Knob Room Temp Display Power Reset Switch 10 Flat Free Wheel 10 Flat Free Wheel Front Handle Upper Shell Rear Handle Cord...

Страница 5: ...eel Support Frame No Yes Yes Wheel No Yes Yes Threaded Axle No Yes Yes Front Handle No Yes Yes Rear Handle No Yes Yes Handle Yes No No Cord Wrap 50H No 80H Yes Yes Yes Hardware kit HW KFA1016 No Yes Y...

Страница 6: ...le wrench Assembling Handle Wheel and Cord Wrap 1 Slide threaded axle through the rear section of the wheel support frame 2 Slide one axle bushing on to each side of the axle Slide one wheel on to eac...

Страница 7: ...accomodate any added contaminants that may be added to the heated space 2 diesel fuel oil heavier than 1 K kerosene in extreme cold temperatures without non toxic anti icer additives will not ignite...

Страница 8: ...ure Limit Control This heater is equipped with a Temperature Limit Control designed to turn off the heater should the internal temperature rise to an unsafe level If this device activates and turns yo...

Страница 9: ...and 99 the number shown on the display is the current room temperature When room temperature is greater than 99 the LED display will show Hi If heater does not start the thermostat setting may be too...

Страница 10: ...nside of the tank NEVER mix water with the kerosene as it will cause rust inside the tank Pour the kerosene out making sure that you remove it all IMPORTANT Do not store kerosene over summer months fo...

Страница 11: ...Removeuppershellandfanguard SeeAirIntakeFilter Turn Air pressure gauge counter clock wise and remove Remove end filter cover screws using medium phillips screwdriver Remove end filter cover Replace ai...

Страница 12: ...emovefan Seepage10 Removefuelandairlinehosesfromnozzleadaptor Removeignitorwirefromsparkplug Removesparkplugfromnozzleadaptorusingmedium phillipsscrewdriver Turnnozzleadaptor1 8turn 45 tocounterclockw...

Страница 13: ...adaptor Attach ignitor wire to spark plug Reinstall fan and upper shell G PHOTOCELL CLEAN PHOTOCELLANNUALLY OR AS NEEDED Removeuppershell Seepage10 Removefan Seepage10 Removephotocellfromit smounting...

Страница 14: ...FA50H 80HModelsonly Startheater SeeOperation page8 Allowmotortoreachfullspeed Adjustpressure Usingaflatbladescrewdriver Turn reliefvalvetoclockwisetoincreasepressure Turn reliefvalvetocounterclockwise...

Страница 15: ...ater 2 Removesidecoverscrewsusingmediumphillipsscrewdriver 3 Disconnectswitchwiresfrompowerswitch 4 Removefusefromfuseholder SeeFigure21 5 Replacefusewithenclosedfuse WARNING FIREHAZARD To avoid fire...

Страница 16: ...d to spark plug 1 Fill tank with kerosene 2 See Pump Pressure Adjustment Page 13 3 See Spark Plug Page 12 4 See Fuel Filter Page 13 5 See Nozzle Page 11 6 Flush fuel tank with clean kerosene Page 9 7...

Страница 17: ...CK FUSE LIMIT PHOTO CELL BLACK POWER BLACK POWER ORANGE BLACK WHITE 8A 125VAC AC120V PLUG BLACK 60Hz GREEN EARTH SWITCH CONTROL RED CN7 15uF 230VAC 20uF 350VAC 135H 220H 80H CAPACITOR MODEL CONTROL PC...

Страница 18: ...0 60 2 27 1 02 3 86 1 66 6 28 LOW N A N A N A 1 36 5 15 Fuel Tank Capacity Gal 5 0 18 9 5 0 18 9 10 0 37 9 13 0 49 2 Fuel Tank Capacity Gal kgf cm2 HIGH 3 8 0 27 3 8 0 27 5 5 0 39 8 5 0 60 LOW N A N...

Страница 19: ...32 33 2 35 5 6 29 30 3 4 1 37 31 36 24 12 11 15 10 16 9 17 15 26 27 18 41 38 42 39 7 8 34 13 19 22 23 22 1 22 7 22 8 25 28 40 20 21 18 14 EXPLODED PARTS DRAWING KFA50H 80H 135H Models Only NOTE SPECI...

Страница 20: ...576 00 SP KFA1026 4349 0016 00 3431 0010 00 3311 0002 00 3231 0239 00 SP KFA1021 4329 0079 00 4319 0015 00 3341 0034 00 2154 0135 00 3970 0210 00 3820 0257 00 3111 0440 00 4331 0022 00 3541 0022 00 43...

Страница 21: ...ard 25 8 25 9 25 10 25 11 25 12 25 13 25 14 25 15 25 16 25 17 25 18 25 19 25 20 25 21 27 26 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 See SP KFA10001 See SP KFA10001 See SP KFA10001 3531 0027 00 32...

Страница 22: ...2 32 5 26 27 3 4 1 34 28 33 22 10 9 8 24 14 7 15 13 23 22 19 18 37 35 18 1 18 2 18 3 18 4 18 5 18 6 18 7 18 8 6 20 11 16 17 36 21 21 14 EXPLODED PARTS DRAWING KFA220H Model Only NOTE SPECIFY MODEL NUM...

Страница 23: ...21 0198 00 See SP KFA10221 See SP KFA10221 See SP KFA10221 3531 0027 00 3231 0181 00 See SP KFA10052 4329 0016 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 18 1 18 2 18 3 18 4 18 5 18 6 18 7 18 8 2...

Страница 24: ...00 215A 0074 00 4312 0046 00 39E0 0071 00 3121 0499 33 39A0 0191 00 3231 0113 00 4319 0015 00 3121 0354 00 4319 0015 00 3111 0505 01 3221 0075 00 4319 0015 00 21 15 21 16 21 17 21 18 21 19 21 20 21 21...

Страница 25: ...Frame 3551 0082 00 3551 0084 00 1 4 Wheel 3720 0017 00 3720 0017 00 2 5 Threaded Axle 3551 0088 00 3551 0089 00 1 6 Cord Wrap 3221 0042 00 3221 0042 00 2 7 Hardware Kit HW KFA1016 HW KFA1016 1 7 1 Sc...

Страница 26: ...do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages...

Страница 27: ...can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records Place Postage Stamp Here SAVE THIS CARD GHP G...

Отзывы: